Adam Briscoe

Adam Briscoe
  • Doctor of Philosophy
  • Manager at Invibio Ltd, Thornton Cleveleys, UK

About

63
Publications
7,082
Reads
How we measure 'reads'
A 'read' is counted each time someone views a publication summary (such as the title, abstract, and list of authors), clicks on a figure, or views or downloads the full-text. Learn more
682
Citations
Current institution
Invibio Ltd, Thornton Cleveleys, UK
Current position
  • Manager

Publications

Publications (63)
Article
Full-text available
Experimental wear simulation of a PEEK-OPTIMA™ polymer-on-UHMWPE total knee replacement has shown equivalent UHMWPE wear to conventional knee replacement materials (cobalt chrome-on-UHMWPE) when tested in a clean environment. The aim of this study was to experimentally investigate the wear of this all-polymer total knee replacement under third body...
Article
Full-text available
Polyetheretherketone (PEEK) is of interest as implant material for cementless tibial total knee arthroplasty (TKA) components due to its potential advantages. One main advantage is that the stiffness of PEEK closely resembles the stiffness of bone, potentially avoiding peri-prosthetic stress-shielding. When introducing a new implant material for ce...
Article
Full-text available
Experimental in vitro simulation can be used to predict the wear performance of total knee replacements. The in vitro simulation should aim to replicate the in vivo loading, motion and environment experienced by the joint, predicting wear and potential failure whilst minimising test artefacts. Experimental wear simulation can be sensitive to enviro...
Article
Full-text available
The use of a more compliant material, such as polyetheretherketone (PEEK), for a cementless femoral component is a potential solution to prevent aseptic loosening caused by peri-prosthetic stress-shielding. Long-term fixation of a cementless femoral component is achieved by a proper primary fixation of the bone-implant interface, which is influence...
Article
Full-text available
Due to their high stiffness, metal femoral implants in total knee arthroplasty may cause stress shielding of the peri-prosthetic bone, which can lead to loss of bone stock. Using a polymer (PEEK) femoral implant reduces the stiffness mismatch between implant and bone, and therefore has the potential to decrease strain shielding. The goal of the cur...
Article
Full-text available
This study investigated the fixation of a cemented PEEK femoral TKA component. PEEK and CoCr implants were subjected to a walking gait cycle for 10 million cycles (MC), 100,000 cycles or 0 cycles (unloaded control). A method was developed to assess the fixation at the cement–implant interface, which exposed the implants to a fluorescent penetrant d...
Article
Full-text available
PEEK-OPTIMA™ is being considered as an alternative to cobalt chrome (CoCr) in the femoral component of total knee replacements. To date, investigations of ultra-high molecular weight polyethylene (UHMWPE)-on-PEEK have shown an equivalent wear rate to conventional implant materials under standard conditions. In this study, the third body wear perfor...
Article
Full-text available
PEEK-OPTIMA™ is being considered as an alternative bearing material to cobalt chrome in the femoral component of total knee replacement to provide a metal-free implant. The aim of this study was to investigate the influence of lubricant temperature (standard rig running and elevated temperature (~36 °C)) on the wear of a UHMWPE-on-PEEK OPTIMA™ bear...
Article
Full-text available
Poly‐ether‐ether‐ketone (PEEK), having shown favorable biocompatibility in spinal applications is being considered as an alternative biomaterial in orthopaedics, either as part of an all‐polymer bearing couple, or a replacement for the metallic component in hard‐on‐soft bearings. Throughout the literature ultra‐high molecular weight polyethylene ex...
Article
Full-text available
Background Conventional total knee replacement designs show high success rates but in the long term, the stiff metal components may affect bone quality of the distal femur. In this study we introduce an all-polymer total knee replacement device containing a PEEK femoral component on an UHMWPE tibial implant and study its mechanical integrity, fixat...
Article
Full-text available
The current study was designed to investigate the mechanical response of a polyetheretherketone-on-polyethylene total knee replacement device during a deep squat. Application of this high-demand loading condition can identify weaknesses of the polyetheretherketone relative to cobalt-chromium. This study investigated whether the implant is strong en...
Article
Introduction Introducing polyetheretherketone (PEEK) polymer as a material for femoral components in total knee arthroplasty (TKA) could potentially lead to a reduction of the cemented fixation strength. A PEEK implant is more likely to deform under high loads, rendering geometrical locking features less effective. Fixation strength may be enhanced...
Article
Full-text available
PEEK-OPTIMA™ (Invibio Ltd., UK) has been considered as an alternative joint arthroplasty bearing material due to its favourable mechanical properties and the biocompatibility of its wear debris. In this study, the potential to use injection moulded PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of a total knee replacement...
Article
Background: All-polymer bearings involving polyetheretherketone (PEEK) have been proposed for orthopaedic applications because they may reduce stress shielding, reduce weight of the implants, reduce wear and risk of osteolysis, and prevent release of metal ions by replacing the metal articulating components. Little is known about the biotribology...
Article
Full-text available
Background Both the material and geometry of a total knee arthroplasty (TKA) component influence the induced periprosthetic bone strain field. Strain, a measure of the local relative deformation in a structure, corresponds to the mechanical stimulus that governs bone remodeling and is therefore a useful in vitro biomechanical measure for assessing...
Article
The idea of all polymer artificial joints, particularly for the knee and finger, has been raised several times in the past 20 years. This is partly because of weight but also to reduce stress shielding in the bone when stiffer materials such as metals or ceramics are used. With this in mind, pin-on-plate studies of various polyetheretherketone prep...
Article
Tissue engineering offers enormous potential for bone regeneration. Despite extensive in vitro and in vivo work, few strategies translate into clinical practice. This paper describes the combination of skeletal stem cells (SSCs) and impaction bone grafting (IBG) for the treatment of patients with bone defects associated with avascular necrosis of t...
Article
Previous in vitro work demonstrated porous PLA and PLGA both had the mechanical strength and sustained the excellent skeletal stem cell (SSC) growth required of an osteogenic bonegraft substitute, for use in impaction bone grafting. The purpose of this investigation was to assess the effects of the addition of hydroxyapatite (HA) to the scaffolds p...
Article
Carbon fibre-reinforced polyetheretherketone is an attractive alternative to ultra-high-molecular-weight polyethylene in artificial joints, but little has been published on the influence of stress on the wear factor. We know that in ultra-high-molecular-weight polyethylene, the wear factor reduces as the normal stress increases, which is counter-in...
Article
Full-text available
This project tests the relationship between the acetabular cup surface characteristics and their initial stability by comparing uncemented (Trabecular Metal (TM) and Trilogy) and cemented polyethylene shells. We hypothesised that different surface properties of uncemented cups will influence the cup stability. Mounted directly onto host bone, TM an...
Article
Full-text available
Background & purpose Skeletal stem cells (SSCs) and impaction bone grafting (IBG) can be combined to produce a mechanically stable living bone composite. This novel strategy has been translated to the treatment of avascular necrosis of the femoral head. Surgical technique, clinical follow-up and retrieval analysis data of this translational case se...
Article
Impaction bone grafting (IBG) with human allograft remains the preferred approach for replacement of lost bone stock during revision hip surgery. Associated problems include cost, disease transmission, and stem subsidence. Synthetic grafts are therefore appealing, and ideally display similar mechanical characteristics as allograft, but with enhance...
Article
A novel material combination of a large diameter Biolox(®) Delta zirconia-toughened-alumina (ZTA) head and a pitch-based carbon fibre reinforced poly ether-ether-ketone (CFR-PEEK) MOTIS(®) cup has been studied. The acetabular cups were inclined at three angles and tested using Durham Hip Simulators. The different inclination angles used did not hav...
Article
Disease transmission, availability and cost of allografts have resulted in significant efforts to find an alternative for use in impaction bone grafting (IBG). Recent studies identified two polymers with both structural strength and biocompatibility characteristics as potential replacements. The aim of this study was to assess whether increasing th...
Article
Full-text available
Tissue engineering has enormous potential for the regeneration of bone defects. Approximately 4 years ago we reported on a 62 year old patient who underwent treatment of a benign cyst in the proximal femur by impaction bone grafting supplemented with autologous bone marrow. The cyst and symptoms subsequently recurred and this patient has now requir...
Article
Fatigue failure of the cement mantle has been proposed as one of the failure processes contributing to aseptic loosening of cemented joint replacements. It has also been suggested that fatigue failure is dramatically accelerated by residual stress generated during the cement polymerisation process. Previous computational models of the polymerisatio...
Article
Pre-clinical wear testing of Total Knee Arthroplasty has traditionally been carried out in a physical experiment [Fisher, 2002]. Recent computational models have been shown to have sufficient accuracy to be considered alongside these experiments [Knight, 2007]. These computational models use a relationship of wear volume proportional to the product...
Conference Paper
Pre-clinical wear testing of Total Knee Arthroplasty has traditionally been carried out in a physical experiment [Fisher, 2002]. Recent computational models have been shown to have sufficient accuracy to be considered alongside these experiments [Knight, 2007]. These computational models use a relationship of wear volume proportional to the product...
Conference Paper
This paper describes a technique for monitoring polymerisation of acrylic bone cements by measuring changes in the characteristics of the transmission of ultrasound through the cement brought about by the polymerisation reaction. To the authors’ knowledge, this is the first time that a technique for the continuous monitoring of the mechanical prope...
Thesis
Total joint replacement is one of the most successful surgical procedures and is a proven treatment for arthritis. Despite low failure rates, the wide application of the treatment means that large numbers of prostheses fail and must be revised. Improved pre-clinical testing methods for these orthopaedic devices may assist in developing new prosthes...
Article
Full-text available
The subject of the cementing technique in hip resurfacing has been poorly studied to date. The hip resurfacing prosthesis is unique in the family of cemented prostheses because the cement mantle is blind (hidden underneath the implant) and is radiographically obscured. This presents an immediate challenge to the surgeon at the time of surgery, but...

Network

Cited By