Question
Asked 17 November 2018

What is the relationship between the contrast and the beam current in the scanning electron microscop or (FIB)?

I need to solve the ion mirror phenomenon that occurs in FIB

Most recent answer

Muayyed Jabar Zoory
Mustansiriyah University
Dear Gert Nolze
See attached file

All Answers (4)

Gert Nolze
Federal Institute For Materials Research and Testing
Which contrast? Beam current is another word for amount of electrons. Contrast is the term describing the gradient in electron detection. From my simple point of view, there is no influence on the gradient if you change the amount of electrons. It becomes better visible but the contrast is still the same. This is totally different for the electron energy since then you really change the physical interaction. Beam current only (primarily) means the same physics but only more often....
2 Recommendations
Muayyed Jabar Zoory
Mustansiriyah University
Dear Gert Nolze
Thank you for your attention. But I mean here why the value of the contrast changes with the different value of the current for the same acceleration scanning voltage
Gert Nolze
Federal Institute For Materials Research and Testing
There are indeed some other effects which might have impact like at high magnification the reduction of resolution. In case of a wider beam theoretically also the contrast might be influenced since the probe size changes. Even the very simple influence "focusing" at different beam currents might be one factor. Moreover, if I take my common image optimization into account...I do not know actually which gain (contrast) I used for the imaging after optimization. In other words, how do you know that the contrast improves? Do you really "save" the electron signal as numbers, or only the image itself? If there is less noise the contrast simply seems to be improved, but actually it isn't. You also should answer my first question :-) . WHICH contrast? About which images you are talking? SE (which one), BSE (Which one)? At which acceleration voltages you are talking? I assumed common conditions like 20keV, 1nA...
However, in order to prevent any speculations you should post both images with all available parameters selected during imaging.
BTW: For FIB the entire discussion has to start again since the imaging formation is different in case of Ga ions and electron imaging.
2 Recommendations
Muayyed Jabar Zoory
Mustansiriyah University
Dear Gert Nolze
See attached file

Similar questions and discussions

Related Publications

Article
Full-text available
Individually released polystyrene-platinum bimorph microcantilevers that have potential applications as MEMS/NEMS thermal actuators are produced using focused ion beam micromachining technique. The microcantilevers are sharply defined and triangular in cross-section, and are about 20µm long, 2 µm wide and 1.5 µm thick. The fabrication process is fa...
Article
Environmental scanning electron microscopes (ESEMs) and variable pressure scanning electron Microscopes (VPSEMs) are now standard instruments, FEI Company offer several models of ESEM and JEOL, Hitachi and Zeiss each offer VPSEMs. In addition, FEI and Zeiss have been offering dual-beam focused ion beam workstations (FIBs) for a number of years. The...
Chapter
It is worth briefly considering why different focusing systems are used for electron microscopes which typically focus 20 to 200 keV electrons, focused ion beam (FIB) systems which typically focus 3 to 30 keV ions from Be+ to Ga+ to Au+, and nuclear microprobes which focus MeV light ions such as protons or He+.
Got a technical question?
Get high-quality answers from experts.