Question
Asked 14th Feb, 2019

What are the relevant EMC/EMI Standards for inverters ?

I'm currently designing a single-phase VSI (for a non-industrial environnement) with taking into account EMC constraints (Emission only). What are the relevant EMC standards for such design and application ?

Most recent answer

23rd Aug, 2021
Karim Kadem
Vedecom
Very helpful thanks for these answers
1 Recommendation

Popular Answers (1)

20th Feb, 2019
Kotb M. Kotb
Budapest University of Technology and Economics
This file should help you, check it from page 10
6 Recommendations

All Answers (6)

15th Feb, 2019
Fabrizio Castaldi
Elettro c.f. s.r.l.
For welding machines, the standard for irradiated and conducted electromagnetic emissions is regulated by the international standard IEC 60974-10: 2014 with related attachments such as IEC 61000-3-12: 2011 which determines limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase
15th Feb, 2019
Sid-Ahmed Aris
Université Clermont Auvergne
20th Feb, 2019
Kotb M. Kotb
Budapest University of Technology and Economics
This file should help you, check it from page 10
6 Recommendations
22nd Feb, 2019
Sid-Ahmed Aris
Université Clermont Auvergne
Kotb M. Kotb Very helpful indeed, thank you !
25th Feb, 2019
Kotb M. Kotb
Budapest University of Technology and Economics
Sid-Ahmed Aris You are welcome, thanks a lot.
1 Recommendation

Similar questions and discussions

How to calculate the ∆i_max maximum current ripple for converter during LCL filter design for three phase VSC?
Discussion
4 replies
  • Akhtar Hussain JavedAkhtar Hussain Javed
LCL filter are used for grid connected three phase inverters. The design of LCL filter is tricky as it can effect the stability of the system. During the design of LCL filter, to calculate converter side inductor, first maximum current ripple is calculated as
∆i_max=V_dc/(6L_i f_sw )
In above equation both ∆i_max and Li are unkown, so some authors[1] suggest to use 10% of Imax for this ripple current. On the other hand, other paper for example [2] and [3] use a relatively complex method to calculate the value of ∆i_max.
My first question is how accurate is use of 10%*Imax approximation? Are there any other quick way or approximations according to standards to find ∆i_max.
My second question is how to find the right attenuation factor δ for particular value of THD?
[1]M. Dursun and M. K. DÖŞOĞLU, "LCL Filter Design for Grid Connected Three-Phase Inverter," 2018 2nd International Symposium on Multidisciplinary Studies and Innovative Technologies (ISMSIT), 2018, pp. 1-4, doi: 10.1109/ISMSIT.2018.8567054.
M. Ben Saïd-Romdhane, M.W. Naouar, I. Slama. Belkhodja, E. Monmasson,
[3]Simple and systematic LCL filter design for three-phase grid-connected power converters,
Mathematics and Computers in Simulation, Volume 130,2016,Pages 181-193,ISSN 0378-4754,

Related Publications

Article
Full-text available
Over the different Modulation Techniques, Pulse Width Modulation is one of the major renowned modulation strategies, because the pulses are generated based on reference signal and the reference signal is sinusoidal. So many modifications are made in this strategy since PWM era starts in the area of Power Electronics, the modifications are like with...
Article
This paper investigates the realization of a five-level Flying Capacitor Inverter. After a brief description of general Power Electronic Converters and an introduction to the advantages of Multilevel Inverters over conventional two-level Inverters the main focus is on the five-level Flying Capacitor Inverter. The Flying Capacitor Multilevel Inverte...