SilicoLife
Question
Asked 11 December 2017
How to carry MD simulations with distance constraint between two residues?
I am using amber to do some molecular dynamics simulation, protein pockets for a long time simulation will become smaller, I want to add the distance limit between the two residues on both sides of the pocket, so that the distance between them should not be less than a certain value. Is this correct? How can I achieve this?
Most recent answer
If you want to fix two atoms with harmonic restraint: https://ambermd.org/tutorials/advanced/tutorial17/section2.htm
1 Recommendation
Popular answers (1)
Institute of Chemical Biology and Fundamental Medicine, Russian Academy of Sciences
You can use the restrains as in this tutorial. You just set the restraints between atoms in residues as you wish. http://ambermd.org/tutorials/advanced/tutorial4/index.htm
4 Recommendations
All Answers (5)
Institute of Chemical Biology and Fundamental Medicine, Russian Academy of Sciences
You can use the restrains as in this tutorial. You just set the restraints between atoms in residues as you wish. http://ambermd.org/tutorials/advanced/tutorial4/index.htm
4 Recommendations
University of Michigan
Hi,
SHAKE is usually used to consytaint the Hydrogens as they are very mobile. As Victor said, you can easily use harmonic restraint between atoms. You can find all the details in Amber manual. You need to define the atoms and the desired distance between those atoms. You can do several restraints on different atoms. You can restraint distance, angle and dihedral, too.
Good luck,
Hedi
1 Recommendation
SilicoLife
If you want to fix two atoms with harmonic restraint: https://ambermd.org/tutorials/advanced/tutorial17/section2.htm
1 Recommendation
Similar questions and discussions
How to make a stable protein-ligand complex during equilibration step in AMBER?
- Manish Paul
Hi,
I am simulating a protein-ligand complex in AMBER. Up to density, the protein-ligand complex remain stable and the ligand still attached to its active site (attached movie: density.mp4). But during the equilibration, the ligand is gradually coming out from its active site and get totally dislodged after the completion of a 50ps equilibration run (attached movie: equil.mp4). I have attached the the prot_lig_solvate.prmtop and equi.in (parameter file). The complex system is 324 residues long (amino acids: 1-323, ligand: 324).
Please anyone help me to resolve this problem so that the protein-ligand complex remain completely stable after the equilibration.
Thanks
Manish.
Related Publications
Molecular dynamics simulation of 4-n-alkyl-4'-cyanobiphenyl series (nCB) using the full-atom model was carried out. We used a force field that was fitting the dihedral angle parameter and the LJ parameters of the AMBER Force Field against nCB. The dihedral angle parameter is set to reference the quantum chemical calculation, and the LJ paramet...