Figure 4 - uploaded by Leenta Grobler
Content may be subject to copyright.
Simulation (dashed and solid lines) and practical (solid lines) AMB models with rotational rotor faults.
Source publication
Contexts in source publication
Context 1
... and practical AMB models A simulation model of the AMB system was necessary to ob- serve how the practical system will respond to faults, when the diagnosis and correction system is implemented. The simula- tion (dashed and solid lines) and practical (solid lines) mod- els of the rotating double radial AMB system with vibration forces are shown in figure 4. ...
Context 2
... 19 shows the actual displacement of the AMB system with multiple frequency vibration forces and dominant super- synchronous vibration force. The system was designed to sim- ulate and capture the actual displacement of the simulation and practical AMB models (shown in figure 4) without any vibration force for the first 10 seconds, thereafter to induce the fault and activate the detection, diagnosis and correction system after 20 seconds. ...