Percentage of yearly hours in air conditioning mode and electricity consumption for air conditioning to avoid effective temperatures above 25 ⁰C. The remaining time, Effective Temperatures above 25 °C was avoided by an air change of 300 m 3 h -1 sow -1 in combination with pad cooling and an air velocity of 2.4 ms -1

Percentage of yearly hours in air conditioning mode and electricity consumption for air conditioning to avoid effective temperatures above 25 ⁰C. The remaining time, Effective Temperatures above 25 °C was avoided by an air change of 300 m 3 h -1 sow -1 in combination with pad cooling and an air velocity of 2.4 ms -1

Context in source publication

Context 1
... for these locations additional calculation were made assuming air conditioning was used in the periods where the combination of high ventilation rate (300 m 3 h -1 sow -1 ), pad cooling and high air velocity (2.4 ms -1 ) was insufficient avoid an Effective Temperature above 25 ⁰C. These calculations were made with an assumed air velocity during air conditioning of either 0.2 or 2.4 ms -1 and the resulting electricity consumption for air condition is indicated in Table 5. Compared to use air conditioning already when the outdoor temperatures exceeded 23 ⁰C (as assumed in Table 1) utilization of pad cooling and increased air velocity before switching to air conditioning reduced the power consumption for air condition by 72-91 percent at an air velocity of 0.2 ms -1 . ...