-
Takashi Uchiyama, Shinji Miyoki,
Souichi Telada,
Kazuhiro Yamamoto,
Masatake Ohashi,
Kazuhiro Agatsuma,
Koji Arai,
Masa-Katsu Fujimoto,
Tomiyoshi Haruyama,
Seiji Kawamura,
Osamu Miyakawa,
Naoko Ohishi,
Takanori Saito,
Takakazu Shintomi,
Toshikazu Suzuki,
Ryutaro Takahashi,
Daisuke Tatsumi
[show abstract]
[hide abstract]
ABSTRACT: The thermal fluctuation of mirror surfaces is the fundamental limitation for interferometric gravitational wave (GW) detectors. Here, we experimentally demonstrate for the first time a reduction in a mirror's thermal fluctuation in a GW detector with sapphire mirrors from the Cryogenic Laser Interferometer Observatory at 17 and 18 K. The detector sensitivity, which was limited by the mirror's thermal fluctuation at room temperature, was improved in the frequency range of 90 to 240 Hz by cooling the mirrors. The improved sensitivity reached a maximum of 2.2×10(-19) m/√Hz at 165 Hz.
Physical Review Letters 04/2012; 108(14):141101. · 7.37 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: We propose new solutions for expanding the linear signal range between the laser frequency deviation (or mirror position) and the voltage signal derived by the Pound-Drever-Hall (PDH) method for optical Fabry-Perot cavity resonance control. One solution is to perform not in-phase demodulation but near-Q-phase demodulation. Another solution is to take a suitable combination of signals demodulated by odd-harmonic modulation frequencies in the in phase. Although the PDH signal sensitivity will be diminished, the PDH signal linear range can be extended. From a practical standpoint, it is desirable that a sideband frequency for the PDH method is near the FP cavity resonance.
Applied Optics 10/2010; 49(28):5217-25. · 1.41 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: The optical property of a large mirror substrate of 250 mm in diameter was successfully measured at the required resolution to meet the target sensitivity of the Large-Scale Cryogenic Gravitational Wave Telescope (LCGT) project. Although the quality of the substrate piece was not sufficient to achieve the target sensitivity, we could present how to cope with the crystal orientation for reducing any negative effect of birefringence of the substrate, and we could also produce useful data for manufacturers to improve the quality.
Classical and Quantum Gravity 08/2010; 27(18):185015. · 3.32 Impact Factor
-
Masaki Ando,
Seiji Kawamura,
Naoki Seto,
Shuichi Sato,
Takashi Nakamura,
Kimio Tsubono,
Takeshi Takashima,
Ikkoh Funaki,
Kenji Numata,
Nobuyuki Kanda, [......],
Yaka Wakabayashi,
Kent Yagi,
Hiroshi Yamakawa,
Kazuhiro Yamamoto,
Toshitaka Yamazaki,
Jun'ichi Yokoyama,
Chul-Moon Yoo,
Shijun Yoshida,
Taizoh Yoshino,
Ke-Xun Sun
[show abstract]
[hide abstract]
ABSTRACT: A space gravitational-wave antenna, DECIGO (DECI-hertz interferometer Gravitational wave Observatory), will provide fruitful insights into the universe, particularly on the formation mechanism of supermassive black holes, dark energy and the inflation of the universe. In the current pre-conceptual design, DECIGO will be comprising four interferometer units; each interferometer unit will be formed by three drag-free spacecraft with 1000 km separation. Since DECIGO will be an extremely challenging mission with high-precision formation flight with long baseline, it is important to increase the technical feasibility before its planned launch in 2027. Thus, we are planning to launch two milestone missions. DECIGO pathfinder (DPF) is the first milestone mission, and key components for DPF are being tested on ground and in orbit. In this paper, we review the conceptual design and current status of DECIGO and DPF.
Classical and Quantum Gravity 04/2010; 27(8):084010. · 3.32 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: We have achieved a direct measurement of the thermal fluctuation of a pendulum in an off-resonant and wide frequency region using a laser interferometric gravitational-wave detector. These measurements have been well identified for over one decade by an agreement with a theoretical prediction, which is derived by a fluctuation-dissipation theorem. Thermal fluctuation was dominated by the contribution of resistances in coil-magnet actuator circuits. When we tuned these resistances, the noise spectrum also changed according to a theoretical prediction. The measured thermal noise level corresponds to a high quality factor on the order of 10(5) of the pendulum.
Physical Review Letters 01/2010; 104(4):040602. · 7.37 Impact Factor
-
Kazuhiro Agatsuma,
Koji Arai,
Masa-Katsu Fujimoto,
Seiji Kawamura,
Kazuaki Kuroda,
Osamu Miyakawa, Shinji Miyoki,
Masatake Ohashi,
Toshikazu Suzuki,
Ryutaro Takahashi,
Daisuke Tatsumi,
Souichi Telada,
Takashi Uchiyama,
Kazuhiro Yamamoto,
CLIO collaborators
[show abstract]
[hide abstract]
ABSTRACT: We report on the current status of CLIO (Cryogenic Laser Interferometer Observatory), which is a prototype interferometer for LCGT (Large Scale Cryogenic Gravitational-Wave Telescope). LCGT is a Japanese next-generation interferometric gravitational wave detector featuring the use of cryogenic mirrors and a quiet underground site. The main purpose of CLIO is to demonstrate a reduction of the mirror thermal noise by cooling the sapphire mirrors. CLIO is located in an underground site of the Kamioka mine, 1000 m deep from the mountain top, to verify its advantages. After a few years of commissioning work, we have achieved a thermal-noise-limited sensitivity at room temperature. One of the main results of noise hunting was the elimination of thermal noise caused by a conductive coil-holder coupled with a pendulum through magnets. Comment: 10 pages, 6 figures, Proceedings of the 8th Edoardo Amaldi Conference on Gravitational Waves
11/2009;
-
[show abstract]
[hide abstract]
ABSTRACT: We investigated the noise of interferometric gravitational wave detectors due to heat energy deposited by cosmic-ray particles. We derived a general formula that describes the response of a mirror against a cosmic-ray passage. We found that there are differences in the comic-ray responses (the dependence of temperature and cosmic-ray track position) in cases of interferometric and resonant gravitational wave detectors. The power spectral density of vibrations caused by low-energy secondary muons is 100-times smaller than the goal sensitivity of future second-generation interferometer projects, such as LCGT and Advanced LIGO. The arrival frequency of high-energy cosmic-ray muons that generate enough large showers inside mirrors of LCGT and Advanced LIGO is one per a millennium. We also discuss the probability of exotic-particle detection with interferometers.
06/2008;
-
Takayuki Tomaru,
Masao Tokunari,
Kazuaki Kuroda,
Takashi Uchiyama,
Akira Okutomi,
Masatake Ohashi,
Hiroyuki Kirihara,
Nobuhiro Kimura,
Yoshio Saito,
Nobuaki Sato,
Takakazu Shintomi,
Toshikazu Suzuki,
Tomiyoshi Haruyama, Shinji Miyoki,
Kazuhiro Yamamoto,
Akira Yamamoto
[show abstract]
[hide abstract]
ABSTRACT: A large heat load caused by thermal radiation through a metal shield pipe was observed in a cooling test of a cryostat for a prototype of a cryogenic interferometric gravitational wave detector. The heat load was approximately 1000 times larger than the value calculated by the Stefan-Boltzmann law. We studied this phenomenon by simulation and experiment and found that it was caused by the conduction of thermal radiation in a metal shield pipe. Comment: 7 pages, 4 figures, 2 tables, Submitted to Jpn. J. Appl. Phys
11/2007;
-
Daisuke Tatsumi,
Ryutaro Takahashi,
Koji Arai,
Noriyasu Nakagawa,
Kazuhiro Agatsuma,
Toshitaka Yamazaki,
Mitsuhiro Fukushima,
Masa-Katsu Fujimoto,
Akiteru Takamori,
Alessandro Bertolini, [......],
Norichika Awaya,
Nobuyuki Kanda,
Akito Araya,
Souichi Telada,
Takayuki Tomaru,
Tomiyoshi Haruyama,
Akira Yamamoto,
Nobuaki Sato,
Toshitaka Suzuki,
Takakazu Shintomi
[show abstract]
[hide abstract]
ABSTRACT: Current status of TAMA and CLIO detectors in Japan is reported in this article. These two interferometric gravitational-wave detectors are being developed for the large cryogenic gravitational wave telescope (LCGT) which is a future plan for detecting gravitational wave signals at least once per year. TAMA300 is being upgraded to improve the sensitivity in low frequency region after the last observation experiment in 2004. To reduce the seismic noises, we are installing new seismic isolation system, which is called TAMA Seismic Attenuation System, for the four test masses. We confirmed stable mass locks of a cavity and improvements of length and angular fluctuations by using two SASs. We are currently optimizing the performance of the third and fourth SASs. We continue TAMA300 operation and R&D studies for LCGT. Next data taking in the summer of 2007 is planned. CLIO is a 100-m baseline length prototype detector for LCGT to investigate interferometer performance in cryogenic condition. The key features of CLIO are that it locates Kamioka underground site for low seismic noise level, and adopts cryogenic Sapphire mirrors for low thermal noise level. The first operation of the cryogenic interferometer was successfully demonstrated in February of 2006. Current sensitivity at room temperature is close to the target sensitivity within a factor of 4. Several observation experiments at room temperature have been done. Once the displacement noise reaches at thermal noise level of room temperature, its improvement by cooling test mass mirrors should be demonstrated.
05/2007;
-
Kazuhiro Yamamoto, Shinji Miyoki,
Takashi Uchiyama,
Hideki Ishitsuka,
Masatake Ohashi,
Kazuaki Kuroda,
Takayuki Tomaru,
Nobuaki Sato,
Toshikazu Suzuki,
Tomiyoshi Haruyama,
Akira Yamamoto,
Takakazu Shintomi,
Kenji Numata,
Koichi Waseda,
Kazuhiko Ito,
Koji Watanabe
[show abstract]
[hide abstract]
ABSTRACT: We have measured the mechanical loss of a dielectric multilayer reflective coating (ion-beam sputtered SiO$_2$ and Ta$_2$O$_5$) in cooled mirrors. The loss was nearly independent of the temperature (4 K $\sim$ 300 K), frequency, optical loss, and stress caused by the coating, and the details of the manufacturing processes. The loss angle was $(4 \sim 6) \times 10^{-4}$. The temperature independence of this loss implies that the amplitude of the coating thermal noise, which is a severe limit in any precise measurement, is proportional to the square root of the temperature. Sapphire mirrors at 20 K satisfy the requirement concerning the thermal noise of even future interferometric gravitational wave detector projects on the ground, for example, LCGT.
02/2006;
-
Masaki Ando,
Tomomi Akutsu,
Tomotada Akutsu,
Koji Arai,
Youichi Aso,
Mitsuhiro Fukushima,
Kazuhiro Hayama,
Nobuyuki Kanda,
Kazuhiro Kondo,
Norikatsu Mio, [......],
Shigeo Nagano,
Shuichi Sato,
Masaru Shibata,
Hideyuki Tagoshi,
Hirotaka Takahashi,
Ryutaro Takahashi,
Daisuke Tatsumi,
Yoshiki Tsunesada,
Toshitaka Yamazaki,
the TAMA Collaboration
[show abstract]
[hide abstract]
ABSTRACT: We present the results of observations with the TAMA300 gravitational-wave detector, targeting burst signals from stellar-core collapse events. We used an excess-power filter to extract gravitational-wave candidates, and developed two methods to reduce fake events caused by non-stationary noises of the detector. These analysis methods were applied to real data from the TAMA300 interferometric gravitational wave detector. We compared the data-processed results with those of a Monte Carlo simulation with an assumed galactic-event distribution model and with burst waveforms expected from numerical simulations of stellar-core collapses, in order to interpret the event candidates from an astronomical viewpoint. We set an upper limit of 5.0 × 103 events s−1 on the burst gravitational-wave event rate in our galaxy with a confidence level of 90%.
Classical and Quantum Gravity 09/2005; 22(18):S1283. · 3.32 Impact Factor
-
Masaki Ando,
Koji Arai,
Youichi Aso,
Peter Beyersdorf,
Kazuhiro Hayama,
Yukiyoshi Iida,
Nobuyuki Kanda,
Seiji Kawamura,
Kazuhiro Kondo,
Norikatsu Mio, [......],
Shigeo Nagano,
Kenji Numata,
Shuichi Sato,
Kentaro Somiya,
Hideyuki Tagoshi,
Hirotaka Takahashi,
Ryutaro Takahashi,
Daisuke Tatsumi,
Yoshiki Tsunesada,
Zong-Hong Zhu
[show abstract]
[hide abstract]
ABSTRACT: We present data-analysis schemes and results of observations with the TAMA300 gravitational-wave detector, targeting burst signals from stellar-core collapse events. In analyses for burst gravitational waves, the detection and fake-reduction schemes are different from well-investigated ones for a chirp-wave analysis, because precise waveform templates are not available. We used an excess-power filter for the extraction of gravitational-wave candidates, and developed two methods for the reduction of fake events caused by non-stationary noises of the detector. These analysis schemes were applied to real data from the TAMA300 interferometric gravitational wave detector. As a result, fake events were reduced by a factor of about 1000 in the best cases. The resultant event candidates were interpreted from an astronomical viewpoint. We set an upper limit of 2.2x10^3 events/sec on the burst gravitational-wave event rate in our Galaxy with a confidence level of 90%. This work sets a milestone and prospects on the search for burst gravitational waves, by establishing an analysis scheme for the observation data from an interferometric gravitational wave detector.
11/2004;
-
Hirotaka Takahashi,
Hideyuki Tagoshi,
Masaki Ando,
Koji Arai,
Peter Beyersdorf,
Nobuyuki Kanda,
Seiji Kawamura,
Norikatsu Mio, Shinji Miyoki,
Shigenori Moriwaki, [......],
Ken-ichi Ueda,
Fumihiko Usui,
Koichi Waseda,
Yuko Watanabe,
Hiromi Yakura,
Kazuhiro Yamamoto,
Akira Yamamoto,
Toshitaka Yamazaki,
Tatsuo Yoda,
Zong-Hong Zhu
[show abstract]
[hide abstract]
ABSTRACT: Japanese laser interferometric gravitational wave detectors, TAMA300 and LISM, performed a coincident observation during 2001. We perform a coincidence analysis to search for inspiraling compact binaries. The length of data used for the coincidence analysis is 275 hours when both TAMA300 and LISM detectors are operated simultaneously. TAMA300 and LISM data are analyzed by matched filtering, and candidates for gravitational wave events are obtained. If there is a true gravitational wave signal, it should appear in both data of detectors with consistent waveforms characterized by masses of stars, amplitude of the signal, the coalescence time and so on. We introduce a set of coincidence conditions of the parameters, and search for coincident events. This procedure reduces the number of fake events considerably, by a factor ∼10-4 compared with the number of fake events in single detector analysis. We find that the number of events after imposing the coincidence conditions is consistent with the number of accidental coincidences produced purely by noise. We thus find no evidence of gravitational wave signals. We obtain an upper limit of 0.046 [1/h] (C.L.=90%) to the galactic event rate within 1 kpc from the Earth. The method used in this paper can be applied straightforwardly to the case of coincidence observations with more than two detectors with arbitrary arm directions.
Phys. Rev. D. 08/2004; 70(4).
-
[show abstract]
[hide abstract]
ABSTRACT: In order to detect the rare astrophysical events that generate gravitational wave (GW) radiation, a sufficient stability is required for GW antennas to allow long-term observation. In practice, seismic excitation is one of the most common disturbances effecting the stable operation of suspended-mirror laser interferometers. A straightforward means to allow a more stable operation is therefore to locate the antenna, the “observatory,” at a “quiet” site. A laser interferometer gravitational wave antenna with a baseline length of 20 m (LISM) was developed at a site 1000 m underground, near Kamioka, Japan. This project was a unique demonstration of a prototype laser interferometer for gravitational wave observation located underground. The extremely stable environment is the prime motivation for going underground. In this paper, the demonstrated ultrastable operation of the interferometer and a well-maintained antenna sensitivity are reported.
Phys. Rev. D. 05/2004; 69(10).
-
B Abbott,
F Abbott,
R Adhikari,
A Ageev,
Bruce Allen,
R Amin,
S B Anderson,
W G Anderson,
M Araya,
H Armandula, [......],
J Worden,
I Yakushin,
H Yamamoto,
S Yoshida,
Ivo Zawischa,
L Zhang,
N Zotov,
M Zucker,
J Zweizig,
M Fyffe
Proceedings of the Thirteenth Workshop on General Relativity and Gravitation in Japan, http://www.scientificcommons.org/20565483; 01/2004
-
B Abbott,
F Abbott,
R Adhikari,
A Ageev,
Bruce Allen,
R Amin,
S B Anderson,
W G Anderson,
M Araya,
H Armandula, [......],
J Worden,
I Yakushin,
H Yamamoto,
S Yoshida,
Ivo Zawischa,
L Zhang,
N Zotov,
M Zucker,
J Zweizig,
M Fyffe
Proceedings of the Thirteenth Workshop on General Relativity and Gravitation in Japan, http://www.scientificcommons.org/20565483; 01/2004
-
Shigeo Nagano,
Seiji Kawamura,
Masaki Ando,
Ryutaro Takahashi,
Koji Arai,
Mitsuru Musha,
Souichi Telada,
Masa-Katsu Fujimoto,
Mitsuhiro Fukushima,
Yoshihide Kozai, [......],
Takashi Nakamura,
Misao Sasaki,
Masaru Shibata,
Hideyuki Tagoshi,
Takahiro Tanaka,
Ken-ichi Nakao,
Ken-ichi Oohara,
Yasufumi Kojima,
Toshifumi Futamase,
Hideki Asada
[show abstract]
[hide abstract]
ABSTRACT: Laser frequency stabilization is essential for interferometric gravitational-wave detectors to attain their target sensitivity. We have designed a multistage laser frequency stabilization system which has been applied in the development of the TAMA 300 gravitational-wave detector in Japan. The control topology consisting of two cascaded loops were employed to secure high feedback gain and reliable detector operation and thus allow the best frequency stability and uninterrupted long-term observation. We achieved simultaneously a frequency stability of 5×10−5 Hz/, and a common-mode rejection ratio (which reduces the coupling of frequency noise to spurious signals in the detector) of 37 dB. The developed system enabled us to operate TAMA 300 with sufficient sensitivity and stability that it had the potential to register gravitational-wave events. The system was confirmed to be suitable for a gravitational-wave detector from the observation run of TAMA 300. © 2003 American Institute of Physics.
Review of Scientific Instruments 08/2003; 74(9):4176-4183. · 1.37 Impact Factor
-
Takayuki Tomaru, Shinji Miyoki,
Masatake Ohashi,
Kazuaki Kuroda,
Takashi Uchiyama,
Toshikazu Suzuki,
Akira Yamamoto,
Takakazu Shintomi,
Akitoshi Ueda,
Daisuke Tatsumi, [......],
Koji Arai,
Masaki Ando,
Koji Watanabe,
Kenji Nakamura,
Masahiko Watanabe,
Kazuhiko Ito,
Izumi Kataoka,
Hiroaki Yamamoto,
Brett Bochner,
Yaron Hefetz
Applied Optics 04/2003; 42(7):1306-7. · 1.41 Impact Factor
-
Takayuki Tomaru, Shinji Miyoki,
Masatake Ohashi,
Kazuaki Kuroda,
Takashi Uchiyama,
Toshikazu Suzuki,
Akira Yamamoto,
Takakazu Shintomi,
Akitoshi Ueda,
Daisuke Tatsumi, [......],
Koji Arai,
Masaki Ando,
Koji Watanabe,
Kenji Nakamura,
Masahiko Watanabe,
Kazuhiko Ito,
Izumi Kataoka,
Hiroaki Yamamoto,
Brett Bochner,
Yaron Hefetz
[show abstract]
[hide abstract]
ABSTRACT: We evaluated the performance of polished mirror surfaces for the TAMA interferometric gravitational wave detector by comparing the experimental results with a wave-front tracing simulation. The TAMA mirror surfaces were polished to a roughness of a few nanometer rms. We confirmed that these polished mirrors do not limit the present TAMA sensitivity and that the target shot-noise sensitivity will be achieved with these mirrors, even if a power-recycling technique is introduced in the next stage of the TAMA.
Applied Optics 11/2002; 41(28):5913-20. · 1.41 Impact Factor
-
Shigeo Nagano,
Mark A. Barton,
Hideki Ishizuka,
Kazuaki Kuroda,
Sumihiro Matsumura,
Osamu Miyakawa, Shinji Miyoki,
Daisuke Tatsumi,
Takayuki Tomaru,
Takashi Uchiyama, [......],
Takahiro Tanaka,
Misao Sasaki,
Hideyuki Tagoshi,
Toshifumi Futamase,
Nobuki Kawashima,
Eiichi Mizuno,
Yasufumi Kojima,
Namio Matsuda,
Ken-ichi Oohara,
Nobuhiro Tsuda
[show abstract]
[hide abstract]
ABSTRACT: We have developed a light source suitable for laser interferometric gravitational-wave detectors. The developed light source has high power, TEM00 mode, linear polarization, high frequency stability, and low intensity noise. The light source with the quality is essential for attaining the goal sensitivity in the TAMA 300 and was found to be available for a observation run of a gravitational-wave detector. © 2002 American Institute of Physics.
Review of Scientific Instruments 04/2002; 73(5):2136-2142. · 1.37 Impact Factor