Liza Valentin

Centers for Disease Control and Prevention, Atlanta, Michigan, United States

Are you Liza Valentin?

Claim your profile

Publications (2)7.19 Total impact

  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Perchlorate, nitrate, and thiocyanate are competitive inhibitors of the sodium iodide symporter of the thyroid membrane. These inhibitors can decrease iodine uptake by the symporter into the thyroid gland and may disrupt thyroid function. This study assesses iodine status and exposure to iodide uptake inhibitors of non-pregnant and non-lactating adult women living in three different cities in Turkey (Istanbul, Isparta and Kayseri). We measured iodine and iodide uptake inhibitors in 24-hr urines collected from study participants (N = 255). All three study populations were mildly iodine deficient, with median urinary iodine (UI) levels of 77.5 µg/L in Istanbul, 58.8 µg/L in Isparta, and 69.8 µg/L in Kayseri. Perchlorate doses were higher in the study population (median 0.13 µg/kg/day), compared with a reference population (median 0.059 µg/kg/day), but lower than the U.S. EPA reference dose (0.7 µg/kg/day). Urinary thiocyanate levels increased with increasing exposure to tobacco smoke, with non-smokers (268 µg/L) significantly lower than light smokers (1110 µg/L), who were significantly lower than heavy smokers (2410 µg/L). This pilot study provides novel data indicating that study participants were moderately iodine deficient and had higher intakes of the iodide uptake inhibitor perchlorate compared with a reference population. Further investigation is needed to characterize the thyroid impact resulting from iodine deficiency coupled with exposure to iodide uptake inhibitors such as perchlorate, thiocyanate and nitrate.
    PLoS ONE 01/2014; 9(2):e88206. · 3.53 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Perchlorate, an inorganic anion, has recently been recognized as an environmental contaminant by the US Environmental Protection Agency. Urine is the preferred matrix for assessment of human exposure to perchlorate. Although the measurement technique for perchlorate in urine was developed in 2005, the calibration and quality assurance aspects of the metrology infrastructure for perchlorate are still lacking in that there is no certified reference material (CRM) traceable to the International System of Units. To meet the quality assurance needs in biomonitoring measurements of perchlorate and the related anions that affect thyroid health, the National Institute of Standards and Technology (NIST), in collaboration with the Centers for Disease Control and Prevention (CDC), developed Standard Reference Material (SRM) 3668 Mercury, Perchlorate, and Iodide in Frozen Human Urine. SRM 3668 consists of perchlorate, nitrate, thiocyanate, iodine, and mercury in urine at two levels that represent the 50th and 95th percentiles, respectively, of the concentrations (with some adjustments) in the US population. It is the first CRM being certified for perchlorate. Measurements leading to the certification of perchlorate were made collaboratively at NIST and CDC using three methods based on liquid or ion chromatography tandem mass spectrometry. Potential sources of bias were analyzed, and results were compared for the three methods. Perchlorate in SRM 3668 Level I urine was certified to be 2.70 ± 0.21 μg L(-1), and for SRM 3668 Level II urine, the certified value is 13.47 ± 0.96 μg L(-1).
    Analytical and Bioanalytical Chemistry 08/2012; 404(6-7):1877-86. · 3.66 Impact Factor