Publications (2)4.62 Total impact
-
Article: A retrospective study comparing neutral protamine hagedorn insulin with glargine as Basal therapy in prednisone-associated diabetes mellitus in hospitalized patients.
[show abstract] [hide abstract]
ABSTRACT: Objective: To compare glycemic outcomes in hospitalized patients with or without type 2 diabetes mellitus receiving neutral protamine Hagedorn insulin (NPH) vs glargine as basal insulin for management of glucocorticoid-associated hyperglycemia.Methods: We conducted a retrospective review of electronic medical records in prednisone-treated adult patients with hyperglycemia in a university hospital. Consecutive patients were selected in both the NPH and glargine cohorts using inclusion and exclusion criteria. Baseline characteristics were assessed in each cohort. Glycemic outcomes were analyzed by comparing fasting blood glucose, mean daily blood glucose concentration, median daily blood glucose concentration, and the number of hypoglycemic episodes on a prespecified index day.Results: One hundred twenty patients were included: 60 patients in the NPH cohort and 60 patients in the glargine cohort. The weight-based insulin requirement was lower in the NPH cohort than in the glargine cohort (0.27 ± 0.2 units/kg vs 0.34 ± 0.2 units/kg [P = .04] for basal insulin and 0.26 ± 0.2 units/kg vs 0.36 ± 0.2 units/kg [P = .03] for bolus insulin). NPH and glargine cohorts were similar regarding age, sex, race, body mass index, hemoglobin A1c, serum creatinine, and prednisone dosage. Glycemic outcomes in the NPH cohort compared with outcomes in the glargine cohort were similar regarding mean fasting blood glucose concentration (134 ± 49 mg/dL vs 139 ± 54 mg/dL [P = .63]), mean daily blood glucose (167 ± 46 mg/dL vs 165 ± 52 mg/dL [P = .79]), median blood glucose (160 ± 49 mg/dL vs 159 ± 57 mg/dL [P = .90]), and number of hypoglycemic episodes per day (0.12 ± 0.3 vs 0.10 ± 0.3 [P = .77]).Conclusions: NPH and glargine appear to be equally effective as basal insulin in the management of hyperglycemia in hospitalized patients receiving prednisone. However, the total daily insulin doses used were lower in the NPH cohort.Endocrine Practice 07/2012; 18(5):712-9. · 2.49 Impact Factor -
Article: Alterations in energy balance following exenatide administration.
[show abstract] [hide abstract]
ABSTRACT: Exenatide is a medication similar in structure and effect to native glucagon-like peptide-1, an incretin hormone with glucose-lowering properties. The aim of the study was to measure the change in total energy expenditure (TEE) and body composition during exenatide administration and by deduction the relative contributions of energy expenditure and energy intake to exenatide-induced weight loss. Forty-five obese (body mass index, 30-40 kg·m⁻²) subjects were identified. After exclusion criteria application, 28 subjects entered into the study and 18 subjects (12 female, 6 male) completed the study, which consisted of 6 visits over 14 weeks and injection of exenatide for an average of 84 ± 5 days. Respiratory gas analysis and doubly labeled water measurements were performed before initiation of exenatide and after approximately 3 months of exenatide administration. The average weight loss from the beginning of injection period to the end of the study in completed subjects was 2.0 ± 2.8 kg (p = 0.01). Fat mass declined by 1.3 ± 1.8 kg (p = 0.01) while the fat-free mass trended downward but was not significant (0.8 ± 2.2 kg, p = 0.14). There was no change in weight-adjusted TEE (p = 0.20), resting metabolic rate (p = 0.51), or physical activity energy expenditure (p = 0.38) and no change in the unadjusted thermic effect of a meal (p = 0.37). The significant weight loss because of exenatide administration was thus the result of decreasing energy intake. In obese nondiabetic subjects, exenatide administration did not increase TEE and by deduction the significant weight loss and loss of fat mass was due to decreased energy intake.Applied Physiology Nutrition and Metabolism 06/2012; 37(5):893-9. · 2.13 Impact Factor