Are you Barbara Dal Bello?

Claim your profile

Publications (3)16.91 Total impact

  • Source
    Article: Performance of liver stiffness measurements by transient elastography in chronic hepatitis.
    [show abstract] [hide abstract]
    ABSTRACT: To compare results of liver stiffness measurements by transient elastography (TE) obtained in our patients population with that used in a recently published meta-analysis. This was a single center cross-sectional study. Consecutive patients with chronic viral hepatitis scheduled for liver biopsy at the outpatient ward of our Infectious Diseases Department were enrolled. TE was carried out by using FibroScan™ (Echosens, Paris, France). Liver biopsy was performed on the same day as TE, as day case procedure. Fibrosis was staged according to the Metavir scoring system. The diagnostic performance of TE was assessed by using receiver operating characteristic (ROC) curves and the area under the ROC curve analysis. Two hundred and fifty-two patients met the inclusion criteria. Six (2%) patients were excluded due to unreliable TE measurements. Thus, 246 (171 men and 75 women) patients were analyzed. One hundred and ninety-five (79.3%) patients had chronic hepatitis C, 41 (16.7%) had chronic hepatitis B, and 10 (4.0%) were coinfected with human immunodeficiency virus. ROC curve analysis identified optimal cut-off value of TE as high as 6.9 kPa for F ≥ 2; 7.9 kPa for F ≥ 3; 9.6 kPa for F = 4 in all patients (n = 246), and as high as 6.9 kPa for F ≥ 2; 7.3 kPa for F ≥ 3; 9.3 kPa for F = 4 in patients with hepatitis C (n = 195). Cut-off values of TE obtained by maximizing only the specificity were as high as 6.9 kPa for F ≥ 2; 9.6 kPa for F ≥ 3; 12.2 kPa for F = 4 in all patients (n = 246), and as high as 7.0 kPa for F ≥ 2; 9.3 kPa for F ≥ 3; 12.3 kPa for F = 4 in patients with hepatitis C (n = 195). The cut-off values of TE obtained in this single center study are comparable to that obtained in a recently published meta-analysis that included up to 40 studies.
    World Journal of Gastroenterology 01/2013; 19(1):49-56. · 2.47 Impact Factor
  • Article: Accuracy of real-time shear wave elastography for assessing liver fibrosis in chronic hepatitis C: A pilot study.
    [show abstract] [hide abstract]
    ABSTRACT: Real-time shear wave elastography (SWE) is a novel, noninvasive method to assess liver fibrosis by measuring liver stiffness. This single-center study was conducted to assess the accuracy of SWE in patients with chronic hepatitis C (CHC), in comparison with transient elastography (TE), by using liver biopsy (LB) as the reference standard. Consecutive patients with CHC scheduled for LB by referring physicians were studied. One hundred and twenty-one patients met inclusion criteria. On the same day, real-time SWE using the ultrasound (US) system, Aixplorer (SuperSonic Imagine S.A., Aix-en-Provence, France), TE using FibroScan (Echosens, Paris, France), and US-assisted LB were consecutively performed. Fibrosis was staged according to the METAVIR scoring system. Analyses of receiver operating characteristic (ROC) curve were performed to calculate optimal area under the ROC curve (AUROC) for F0-F1 versus F2-F4, F0- F2 versus F3-F4, and F0-F3 versus F4 for both real-time SWE and TE. Liver stiffness values increased in parallel with degree of liver fibrosis, both with SWE and TE. AUROCs were 0.92 (95% confidence interval [CI]: 0.85-0.96) for SWE and 0.84 (95% CI: 0.76-0.90) for TE (P = 0.002), 0.98 (95% CI: 0.94-1.00) for SWE and 0.96 (95% CI: 0.90-0.99) for TE (P = 0.14), and 0.98 (95% CI: 0.93-1.00) for SWE and 0.96 (95% CI: 0.91-0.99) for TE (P = 0.48), when comparing F0-F1 versus F2- F4, F0- F2 versus F3-F4, and F0 -F3 versus F4, respectively. Conclusion: The results of this study show that real-time SWE is more accurate than TE in assessing significant fibrosis (≥F2). With respect to TE, SWE has the advantage of imaging liver stiffness in real time while guided by a B-mode image. Thus, the region of measurement can be guided with both anatomical and tissue stiffness information. (HEPATOLOGY 2012).
    Hepatology 07/2012; · 11.66 Impact Factor
  • Source
    Article: Performance of real-time strain elastography, transient elastography, and aspartate-to-platelet ratio index in the assessment of fibrosis in chronic hepatitis C.
    [show abstract] [hide abstract]
    ABSTRACT: The purpose of this article is to evaluate the diagnostic performance of transient elastography, real-time strain elastography, and aspartate-to-platelet ratio index in assessing fibrosis in patients with chronic hepatitis C by using histologic Metavir scores as reference standard. Consecutive patients with chronic hepatitis C scheduled for liver biopsy were enrolled. Liver biopsy was performed on the same day as transient elastography and real-time strain elastography. Transient elastography and real-time strain elastography were performed in the same patient encounter by a single investigator using a medical device based on elastometry and an ultrasound machine, respectively. Diagnostic performance was assessed by using receiver operating characteristic curves and area under the receiver operating characteristic curve (AUC) analysis. One hundred thirty patients (91 men and 39 women) were analyzed. The cutoff values for transient elastography, real-time strain elastography, and aspartate-to-platelet ratio index were 6.9 kPa, 1.82, and 0.37, respectively, for fibrosis score of 2 or higher; 7.3 kPa, 1.86, and 0.70, respectively, for fibrosis score of 3 or higher; and 9.3 kPa, 2.33, and 0.70, respectively, for fibrosis score of 4. AUC values of transient elastography, real-time strain elastography, aspartate-to-platelet ratio index were 0.88, 0.74, and 0.86, respectively, for fibrosis score of 2 or higher; 0.95, 0.80, and 0.89, respectively, for fibrosis score of 3 or higher; and 0.97, 0.80, and 0.84, respectively, for fibrosis score of 4. A combination of the three methods, when two of three were in agreement, showed AUC curves of 0.93, 0.95, and 0.95 for fibrosis scores of 2 or higher, 3 or higher, and 4, respectively. Transient elastography, real-time strain elastography, and aspartate-to-platelet ratio index values were correlated with histologic stages of fibrosis. Transient elastography offered excellent diagnostic performance in assessing severe fibrosis and cirrhosis. Real-time elastography does not yet have the potential to substitute for transient elastography in the assessment of liver fibrosis.
    American Journal of Roentgenology 07/2012; 199(1):19-25. · 2.78 Impact Factor