Are you P Mullick?

Claim your profile

Publications (2)1.03 Total impact

  • Article: Spectrophotometric methods for the estimation of mycophenolate mofetil
    [show abstract] [hide abstract]
    ABSTRACT: An attempt was made to develop and validate a novel, simple, cost effective, accurate, and reproducible UV-spectrophotometric method to estimate mycophenolate mofetil in bulk and pharmaceutical formulations. Mycophenolate mofetil was estimated at 250 nm in 0.1N hydrochloric acid (pH 1.2) and in acetate buffer (pH 4.5). Beer’s law was obeyed in the concentration range of 5–40 μg/ml in hydrochloric acid and in the acetate buffer medium. The methods were tested and validated for various parameters according to ICH guidelines. The proposed methods were successfully applied for the determination of mycophenolate mofetil in pharmaceutical formulations (tablets and capsules). The results demonstrate that the procedure is accurate, precise, and reproducible (relative standard deviation <2%) while being simple, cheap, and less time-consuming, and hence can be suitably applied for the estimation of mycophenolate mofetil in different dosage forms and for dissolution studies.
    Journal of Applied Spectroscopy 05/2012; 76(6):876-882. · 0.51 Impact Factor
  • Source
    Article: SPECTROPHOTOMETRIC METHODS FOR THE ESTIMATION OF MYCOPHENOLATE MOFETIL СПЕКТРОФОТОМЕТРИЧЕСКИЕ МЕТОДЫ КОЛИЧЕСТВЕННОГО ОПРЕДЕЛЕНИЯ МОФЕТИЛА МИКОФЕНОЛАТА
    [show abstract] [hide abstract]
    ABSTRACT: An attempt was made to develop and validate a novel, simple, cost effective, accurate, and repro-ducible UV-spectrophotometric method to estimate mycophenolate mofetil in bulk and pharmaceutical formulations. Mycophenolate mofetil was estimated at 250 nm in 0.1N hydrochloric acid (pH 1.2) and in acetate buffer (pH 4.5). Beer's law was obeyed in the concentration range of 5–40 µg/ml in hydro-chloric acid and in the acetate buffer medium. The methods were tested and validated for various pa-rameters according to ICH guidelines. The proposed methods were successfully applied for the deter-mination of mycophenolate mofetil in pharmaceutical formulations (tablets and capsules). The results demonstrate that the procedure is accurate, precise, and reproducible (relative standard deviation <2%), while being simple, cheap, and less time-consuming, and hence can be suitably applied for the estimation of mycophenolate mofetil in different dosage forms and for dissolution studies. (Поступила 7 апреля 2009) Разработан и обоснован новый, несложный, недорогой и отличающийся высокой точно-стью и воспроизводимостью метод спектрофотометрического анализа в УФ области спектра для оценки концентрации мофетила микофенолата в активных фармацевтических ингредиен-тах и фармацевтических составах. Анализ мофетила микофенолата проведен на длине волны 250 нм в растворе соляной кислоты (0.1 N, pH 1.2) и в ацетатном буфере (pH 4.5). Выполнение закона Бэра наблюдалось для концентрации в диапазоне 5–40 мкг/мл как в растворе соляной ки-слоты, так и в ацетатном буфере. Проверка и обоснование методов проведено в соответствии с директивами ICH (Международной конференции по гармонизации). Предлагаемые методы успешно применены для определения содержания мофетила микофенолата в фармацевтических составах (таблетках и капсулах). Как показали результаты исследований, описываемая проце-дура отличается высокой точностью и воспроизводимостью (относительное стандартное отклонение <2%) и в то же время относительно проста, недорога и отнимает меньше време-ни, что делает ее пригодной для количественного определения мофетила микофенолата в раз-личных лекарственных формах и для исследования растворимости препаратов. Ключевые слова: мофетил микофенолата, спектрофотометрический метод, валидация.
    Journal of Applied Spectroscopy 11/2009; · 0.51 Impact Factor