ABSTRACT: BACKGROUND: Tube current modulation in retrospective ECG gated cardiac computed tomography (CT) results in increased image noise and may reduce the accuracy of left ventricular (LV) ejection fraction (EF) and mass assessment. OBJECTIVE: To examine the effects of a novel CT phase-based noise reduction (NR) algorithm on LV EF and mass quantification as compared to cardiac magnetic resonance (CMR). METHODS: In 40 subjects, we compared the LV EF and mass between CT and CMR. In a subset of 24 subjects with tube current modulated CT, the effect of phase-based noise reduction strategies on contrast-to-noise ratio (CNR) and the assessment of LV EF and mass was compared to CMR. RESULTS: There was excellent correlation between CT and CMR for EF (r=0.94) and mass (r=0.97). As compared to CMR, the limits of agreement improved with increasing strength of NR strategy. There was a systematic underestimation of LV mass by CT compared to CMR with no NR (-10.3±10.1g) and low NR (-10.3±12.5g), but was attenuated with high NR (-0.5±8.3g). Studies without NR had lower CNR compared to low and high NR at both the ES phase and ED phase (all p<0.01). CONCLUSIONS: A high NR strategy on tube current modulated functional cardiac CT improves correlation of EF compared to CMR and reduces variability of EF and mass evaluation by increasing the CNR. In an effort to reduce radiation dose with tube current modulation, this strategy provides better image quality when LV function and mass quantification is needed.
European journal of radiology 03/2013; · 2.65 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: Various electrophysiological procedures and device implantation has been shown to improve morbidity and mortality in patients with atrial fibrillation (AF) and patients with heart failure (HF). Noninvasive cardiac imaging is used extensively in the preprocedural patient selection and for procedural guidance. In this review, we will discuss the application of preprocedural cardiac imaging in patients with AF prior to pulmonary vein and left atrial ablation as well as insertion of left atrial occluder device. We also discuss the role of noninvasive cardiac imaging in the selection of appropriate HF patients for device therapy as well as their use in guiding implantation of biventricular pacemaker for cardiac resynchronization therapy by assessing left ventricular ejection fraction, coronary venous anatomy, mechanical dyssynchrony and myocardial scar. We describe new research associated with preprocedural imaging in these patient cohorts.
Current Cardiology Reports 07/2012; 14(5):584-92.
-
[show abstract]
[hide abstract]
ABSTRACT: The efforts to reduce radiation from cardiac computed tomography (CT) are essential. Using a prospectively triggered, high-pitch dual-source CT protocol, we aim to determine the radiation dose and image quality in patients undergoing pulmonary vein (PV) imaging.
In 94 patients (61±9 years; 71% male) who underwent 128-slice dual-source CT (pitch 3.4), radiation dose and image quality were assessed and compared between 69 patients with sinus rhythm and 25 patients with atrial fibrillation. Radiation dose was compared in a subset of 19 patients with prior retrospective or prospectively triggered CT PV scans without high pitch. In a subset of 18 patients with prior magnetic resonance imaging for PV assessment, PV anatomy and scan duration were compared with high-pitch CT. Using the high-pitch protocol, total effective radiation dose was 1.4 (1.3, 1.9) mSv, with no difference between sinus rhythm and atrial fibrillation (1.4 versus 1.5 mSv; P=0.22). No high-pitch CT scans were nondiagnostic or had poor image quality. Radiation dose was reduced with high-pitch (1.6 mSv) compared with standard protocols (19.3 mSv; P<0.0001). This radiation dose reduction was seen with sinus rhythm (1.5 versus 16.7 mSv; P<0.0001) but was more profound with atrial fibrillation (1.9 versus 27.7 mSv; P=0.039). There was excellent agreement of PV anatomy (κ 0.84; P<0.0001) and a shorter CT scan duration (6 minutes) compared with magnetic resonance imaging (41 minutes; P<0.0001).
Using a high-pitch dual-source CT protocol, PV imaging can be performed with minimal radiation dose, short scan acquisition, and excellent image quality in patients with sinus rhythm or atrial fibrillation. This protocol highlights the success of new cardiac CT technology to minimize radiation exposure, giving clinicians a new low-dose imaging alternative to assess PV anatomy.
Circulation Arrhythmia and Electrophysiology 05/2012; 5(3):521-30. · 6.46 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: BACKGROUND: Multi-detector cardiac computed tomography (CT) allows for simultaneous assessment of aortic distensibility (AD), coronary atherosclerosis, and thoracic aortic atherosclerosis. OBJECTIVES: We sought to determine the relationship of AD to the presence and morphological features in coronary and thoracic atherosclerosis. METHODS: In 293 patients (53±12years, 63% male), retrospectively-gated MDCT were performed. We measured intraluminal aortic areas across 10 phases of the cardiac cycle (multiphase reformation 10% increments) at pre-defined locations to calculate the ascending, descending, and local AD (at locations of thoracic plaque). AD was calculated as maximum change in area/(minimum area×pulse pressure). Coronary and thoracic plaques were categorized as calcified, mixed, or non-calcified. RESULTS: Ascending and descending AD were lower in patients with any coronary plaque, calcified or mixed plaque than those without (all p<0.0001) but not with non-calcified coronary plaque (p≥0.46). Per 1mm Hg(-1) 10(-3) increase in ascending and descending AD, there was an 18-29% adjusted risk reduction for having any coronary, calcified plaque, or mixed coronary plaque (ascending AD only) (all p≤0.04). AD was not associated with non-calcified coronary plaque or when age was added to the models (all p>0.39). Local AD was lower at locations of calcified and mixed thoracic plaque when compared to non-calcified thoracic atherosclerosis (p<0.04). CONCLUSIONS: A stiffer, less distensible aorta is associated with coronary and thoracic atherosclerosis, particularly in the presence of calcified and mixed plaques, suggesting that the mechanism of atherosclerosis in small and large vessels is similar and influenced by advancing age.
International journal of cardiology 05/2012; · 7.08 Impact Factor