J M May

City University London, London, ENG, United Kingdom

Are you J M May?

Claim your profile

Publications (2)0 Total impact

  • Article: Photoplethysmographic and SpO(2) readings from the neonatal anterior fontanelle: A case Study.
    [show abstract] [hide abstract]
    ABSTRACT: There is a need for a more reliable, non-invasive and alternative measurement site for the monitoring of arterial blood oxygen saturation in critically ill neonates when peripheral perfusion is poor. The anterior fontanelle, a unique anatomical feature of the neonate, has been presented as an alternative site for the estimation of arterial blood oxygen saturation (SpO(2)). A new fontanelle photoplethysmographic sensor and processing system has been developed to investigate fontanelle photoplethysmographic (PPG) signals and estimate SpO(2) values at this anatomical location. Preliminary clinical trials have shown that good quality PPG signals with large amplitudes and high signal to noise ratio can be obtained from the neonatal fontanelle. The estimation of SpO(2) values from the fontanelle were in broad agreement with a commercial foot pulse oximeter.
    Conference proceedings: ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference 08/2012; 2012:1619-22.
  • Article: Development of an optoelectronic sensor for the investigation of photoplethysmographic signals from the anterior fontanel of the newborn.
    [show abstract] [hide abstract]
    ABSTRACT: There is a need for more reliable, non-invasive and alternative measurement sites for the monitoring of arterial blood oxygen saturation in critically ill newborns at times of peripheral compromise. The anterior fontanelle, a unique anatomical feature of the newborn, has been presented as an alternative site for the estimation of oxygen saturation. A multi-wavelength non-invasive optoelectronic sensor has been designed and developed for the investigation of photoplethysmographic (PPG) signals and blood oxygen saturation values from the fontanelle. In vivo thermal tests of the optical sensor show that under normal operating conditions the heating at the skin surface was negligible (<0.1 °C). Good quality PPGs with large amplitudes and high signal to noise ratio were recorded at all three (red, infrared and green) wavelengths prior to clinical measurements.
    Conference proceedings: ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference 08/2011; 2011:18-21.

Institutions

  • 2011
    • City University London
      • School of Engineering and Mathematical Sciences
      London, ENG, United Kingdom