Publications (43)76.05 Total impact
-
Article: Optimization parameters for BDE in BNCT using near threshold 7Li(p,n)7Be direct neutrons.
[show abstract] [hide abstract]
ABSTRACT: The dose contribution of (10)B(n,alpha)(7)Li reaction in BNCT using near threshold (7)Li(p,n)(7)Be direct neutrons can be increased through the use of materials referred to as boron-dose enhancers (BDE). In this paper, possible BDE optimization criteria were determined from the characteristics of candidate BDE materials namely (C(2)H(4))(n), (C(2)H(3)F)(n), (C(2)H(2)F(2))(n), (C(2)HF(3))(n), (C(2)D(4))(n), (C(2)F(4))(n), beryllium metal, graphite, D(2)O and (7)LiF. The treatable protocol depth (TPD) was used as the assessment index for evaluating the effect of these materials on the dose distribution in a medium undergoing BNCT using near threshold (7)Li(p,n)(7)Be direct neutrons. The maximum TPD (TPD(max)) did not exhibit an explicit dependence on material type as evidenced by its small range and arbitrary variations. The dependence of TPD on BDE thickness was influenced by the BDE material used as indicated by the sharply peaked TPD versus BDE thickness curves for materials with hydrogen compared to the broader curves obtained for those without hydrogen. The BDE thickness required to achieve TPD(max) (BDE(TPD(max))) were also found to be thinner for materials with hydrogen. The TPD(max), the dependence of TPD on BDE thickness, and the BDE(TPD(max)) were established as appropriate BDE optimization parameters. Based on these criteria and other practical considerations, the suitable choice as BDE among the candidate materials considered in this study for treatments involving tumors located at shallow depths would be (C(2)H(4))(n) while beryllium metal was judged as more appropriate for treatment of deep-seated tumors.Applied Radiation and Isotopes 12/2004; 61(5):1003-8. · 1.17 Impact Factor -
Article: Evaluation of the characteristics of boron-dose enhancer (BDE) materials for BNCT using near threshold 7Li(p,n)7Be direct neutrons.
[show abstract] [hide abstract]
ABSTRACT: The characteristics of a number of candidate boron-dose enhancer (BDE) materials for boron neutron capture therapy (BNCT) using near threshold 7Li(p,n)7Be direct neutrons were evaluated based on the treatable protocol depth (TPD), defined in this paper. Simulation calculations were carried out by means of MCNP-4B transport code for candidate BDE materials, namely, (C2H4)n, (C2H3F)n, (C2H2F2)n, (C2HF3)n, (C2D4)n, (C2F4)n, beryllium metal, graphite, D2O and 7LiF. Dose protocols applied were those used for intra-operative BNCT treatment for brain tumour currently used in Japan. The maximum TPD (TPDmax) for each BDE material was found to be between 4 cm and 5 cm in the order of (C2H4)n < (C2H3F)n < (C2H2F2)n < (C2HF3)n < beryllium metal < (C2D4)n < graphite < (C2F4)n < D2O < 7LiF. Based on the small and arbitrary variations in the TPDmax for these materials, an explicit advantage of a candidate BDE material could not be established from the TPDmax alone. The dependence of TPD on BDE thickness was found to be influenced by the type of BDE material. For materials with hydrogen, sharp variations in TPD were observed, while those without hydrogen exhibited more moderate fluctuations in TPD as the BDE thickness was varied. The BDE thickness corresponding to TPDmax (BDE(TPDmax)) was also found to depend on the type of BDE material used. Thicker BDE(TPDmax), obtained mostly for BDE materials without hydrogen, significantly reduced the dose rates within the phantom. The TPDmax, the dependence of TPD on BDE thickness and the BDE (TPDmax) were ascertained as appropriate optimization criteria in choosing suitable BDE materials for BNCT. Among the candidate BDE materials considered in this study. (C2H4)n was judged as the suitable material for near-surface tumours and beryllium metal for deeper tumours based on these optimization criteria and other practical considerations.Physics in Medicine and Biology 03/2004; 49(5):819-31. · 2.83 Impact Factor -
Article: Irradiation characteristics of BNCT using near-threshold 7Li(p, n)7Be direct neutrons: application to intra-operative BNCT for malignant brain tumours.
[show abstract] [hide abstract]
ABSTRACT: A calculation method for the dosage of neutrons by near-threshold 7Li(p, n)7Be and gamma rays by 7Li(p, p'gamma)7Li was validated through experiments with variable distance between the Li target and the phantom, focusing on large angular dependence. The production of neutrons and gamma rays in the Li target was calculated by Lee's method and their transport in the phantom was calculated using the MCNP-4B code. The dosage in intra-operative boron neutron capture therapy (BNCT) using near-threshold 7Li(p, n)7Be direct neutrons was evaluated using the validated calculation method. The effectiveness of the usage of the direct neutrons was confirmed from the existence of the region satisfying the requirements of the protocol utilized in intra-operative BNCT for brain tumours in Japan. The boron-dose enhancer (BDE) introduced in this paper to increase the contribution of the 10B(n, alpha)7Li dose in the living body was effective. The void utilized to increase the dose in deep regions was also effective with BDE. For the investigation of 1.900 MeV proton beams, for example, it was found that intraoperative BNCT using near-threshold 7Li(p, n)7Be direct neutrons is feasible.Physics in Medicine and Biology 09/2002; 47(16):3011-32. · 2.83 Impact Factor
Top Journals
Institutions
-
2009–2013
-
Sapporo Medical University
- • School of Medicine
- • Center for Medical Education
Sapporo-shi, Hokkaido, Japan
-
-
2002–2011
-
Kyoto University
- • Research Reactor Institute
- • Department of Nuclear Engineering
Kyoto, Kyoto-fu, Japan
-
-
2010
-
National Institute of Advanced Industrial Science and Technology
Ibaraki, Osaka-fu, Japan
-
-
2005–2010
-
Hiroshima University
- • Graduate School of Engineering
- • Research Institute for Radiation Biology and Medicine (RIRBM)
Hiroshima-shi, Hiroshima-ken, Japan
-