  • Article: [Therapy for static scapholunate instability -- reconstruction of the dorsal part of the scapholunate ligament with a periosteal flap of the iliac crest].
    [show abstract] [hide abstract]
    ABSTRACT: Recurrent instability is frequent following capsulodesis, tenodesis, or ligament reconstruction in static scapholunate instability. Therefore a periosteal flap of the iliac crest was designed to reconstruct the dorsal part of the SL ligament, which is known to be the biomechanically strongest portion and also the axis of rotation between the scaphoid and lunate. Biomechanical testing of ten fresh frozen dorsal SL ligaments and ten periosteal flaps of the iliac crest showed similar properties concerning failure force, failure displacement, failure stress, energy to failure and stiffness. Results of eight specimens in each group were available following successful testing. Failure force of the dorsal SL ligament was 171.8 N (SD 44.2), energy to failure amounted 269.1 N-mm (SD 98.9), failure stress was 10.3 N/mm (2) (SD 1.3), failure displacement 2.9 mm (SD 0.4), and stiffness 77.2 N/mm (SD 21.4). Testing of the periosteal flap gave the following values: failure force 144.3 N (SD 38.7), energy to failure 217.9 N-mm (SD 85.0), failure stress 9.9 N/mm (2) (SD 1.7), failure displacement 3.0 mm (SD 0.4) and stiffness 60.5 N/mm (SD 14.7). In addition to these test values, clinical and radiological data of eleven patients were available following reconstruction of the dorsal SL ligament with a periosteal flap of the iliac crest. The interval between trauma and surgery was 15 months, mean follow-up was 29 months. One patient was free of pain, whereas ten mentioned pain during or following strenuous work. Two patients were completely satisfied, nine complained about some restriction during special activities. Active range of motion amounted to 56 degrees extension, 46 degrees flexion, 17 degrees radial abduction, 30 degrees ulnar abduction. Grip strength was 38.5 kg, which was 79 % of the contralateral side. Radiological evaluation demonstrated a correction of the static instability in nine cases. In two patients recurrence of static instability was obvious. The prerequisite for success of the procedure is the easy reduction of the carpals. In cases of a fixed rotatory subluxation of the scaphoid, the technique cannot maintain the reduction.
    Handchirurgie · Mikrochirurgie · Plastische Chirurgie 11/2005; 37(5):295-302. · 0.88 Impact Factor
  • Article: Sagittal wrist motion of carpal bones following intraarticular fractures of the distal radius.
    [show abstract] [hide abstract]
    ABSTRACT: Forty patients (mean age, 37 years) with intraarticular C2 and C3 Colles fractures were treated by open reduction, internal fixation and bone grafting. At a mean follow-up of 8 years radiocarpal and midcarpal motion was evaluated, the depth of the articular surface of the distal radius in the sagittal plane was measured and the presence of arthritis was noted. The fractures healed with a mean palmar tilt of 6 degrees , a mean ulnar tilt of 18 degrees and ulna variance within 1 mm of the contralateral side. The depth of the articular surface of the distal radius was 1.3 mm greater than the uninvolved side. Measurement of carpal bone angles relative to the radius in maximum flexion and extension revealed lunate extension of 23 degrees , lunate flexion of 15 degrees , capitate extension of 62 degrees , capitate flexion of 40 degrees . There was a significant correlation between articular surface depth and radiocarpal motion.
    The Journal of Hand Surgery British & European Volume 07/2005; 30(3):282-7. · 0.04 Impact Factor
  • Source
    Article: Use of low molecular mass heparin (enoxaparin) in newborn infants: a prospective cohort study of 62 patients.
    [show abstract] [hide abstract]
    ABSTRACT: To detail low molecular mass heparin (enoxaparin) use in the first few months of life. Prospective, consecutive cohort of unselected newborn infants. Newborn infants were divided into groups by gestational age, underlying condition, hepatic and renal function, thrombocytopenia, and prothrombin time (PT/INR). Groups were analysed with respect to many aspects of enoxaparin treatment using multivariate methods. Sixty two newborn infants received enoxaparin representing 5.39 treatment years. Thromboembolic events (TEs) occurred predominantly in the lower and upper venous system in the presence of indwelling catheters (69%). Preterm infants required longer than full term infants to achieve an anti-(factor Xa) level in the target range (six versus two days). Preterm infants required higher doses of enoxaparin than full term infants to maintain anti-(factor Xa) levels in the target range (2.1 v 1.7 mg/kg/12 h). Infants with congenital heart disease (CHD) required less enoxaparin than those without CHD to maintain an anti-(factor Xa) level in the target range (1.7 v 2.1 mg/kg/12 h). Impaired renal and liver function influenced the number of dose changes needed (three versus one a month). Complete or partial resolution of TE was accomplished in 59% of newborn infants. Four infants developed major bleeds (1.2% per patient year). Recurrent TE and clot extension occurred in three infants (0.9% per patient year). Preterm infants are more difficult to treat with enoxaparin than full term infants. Enoxaparin appears to be an alternative to treatment with standard heparin or no treatment.
    Archives of Disease in Childhood - Fetal and Neonatal Edition 10/2003; 88(5):F365-70. · 3.05 Impact Factor
  • Article: Balloon dilation for aortic recoarctation: morphology at the site of dilation and long-term efficacy.
    [show abstract] [hide abstract]
    ABSTRACT: We undertook this study to assess the immediate and long-term outcome of balloon angioplasty performed for recurrent or residual coarctation of the aorta, and to assess the changes in the vessel wall caused by this procedure. Clinical, echocardiographic, angiographic and hemodynamic data from 71 patients who underwent balloon angioplasty for recoarctation between January 1987 and January 1998 were analysed retrospectively. Angioplasty was performed after a median of 82.6 months (range 1.4 mo-20.9 y, mean 88.5 mo) following surgery for coarctation. Mean systolic pressure gradients were reduced from 27 +/- 15 mmHg to 11 +/- 11 mmHg after angioplasty (p < 0.0001). The mean diameter at the site of recoarctation increased from 5.5 +/- 2.5 to 7.5 +/- 2.7 mm (p < 0.0001). Outpouchings of contrast agents, indicating the disruption of the inner layers of the vessel wall, were defined as extravasations. They were observed in one-quarter of the angiograms performed immediately after the intervention. Immediate success of angioplasty was achieved in 71%, and persisted in 69% of patients during long-term follow up. The main determinant for immediate success was the age at the time of the procedure (p < 0.05), while the main determinant for long-term success was the increase achieved in diameter. Extravasations did not progress to aneurysms, neither acutely nor during echocardiographic follow-up studies. For further follow-up, more sensitive imaging techniques will be necessary to delineate the morphology of the site of extravasation observed immediately after angioplasty.
    Cardiology in the Young 02/2001; 11(1):30-5. · 0.76 Impact Factor