Kyul Kim

Chonnam National University, Kwangju, Gwangju, South Korea

Are you Kyul Kim?

Claim your profile

Publications (2)1.24 Total impact

  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: The aim of this study was to evaluate the surface properties and biological response of an anodized titanium surface by cell proliferation and alkaline phosphatase activity analysis. Commercial pure titanium (Ti) disks were prepared. The samples were divided into an untreated machined Ti group and anodized Ti group. The anodization of cp-Ti was formed using a constant voltage of 270 V for 60 seconds. The surface properties were evaluated using scanning electron microscopy, X-ray photoelectron spectroscopy, and an image analyzing microscope. The surface roughness was evaluated by atomic force microscopy and a profilometer. The contact angle and surface energy were analyzed. Cell adhesion, cell proliferation, and alkaline phosphatase activity were evaluated using mouse MC3T3-E1 cells. The anodized Ti group had a more porous and thicker layer on its surface. The surface roughness of the two groups measured by the profilometer showed no significant difference (P>0.001). The anodized Ti dioxide (TiO2) surface exhibited better corrosion resistance and showed a significantly lower contact angle than the machined Ti surface (P>0.001). Although there was no significant difference in the cell viability between the two groups (P>0.001), the anodized TiO2 surface showed significantly enhanced alkaline phosphatase activity (P<0.001). These results suggest that the surface modification of Ti by anodic oxidation improved the osteogenic response of the osteoblast cells.
    Journal of periodontal & implant science 08/2013; 43(4):198-205.
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: The purpose of this study was to evaluate the reproducibility of the soft tissue (ST) thicknesses at 31 landmarks using the cone-beam computed tomography (CBCT) images obtained from 20 adult subjects. Four observers carried out ST thickness measurements using Skull Measure software, and the inter- and intra-observer error rates were evaluated. Only five of 31 landmarks showed significant differences in recorded ST thickness between the observers. When excluding inexperienced observers, only one landmark showed a significant difference between the observers. Regarding the intra-observer reproducibility, the ST thickness measurements at three landmarks showed low correlation coefficients. The results of this study indicate that CBCT images can be used to measure ST thickness with high reproducibility. However, some landmarks need to be redefined to reliably measure ST thickness on CBCT images.
    Journal of Forensic Sciences 12/2011; 57(2):443-8. · 1.24 Impact Factor