Are you Hong Min?

Claim your profile

Publications (4)10.29 Total impact

  • Article: Au-TiO2/Chit modified sensor for electrochemical detection of trace organophosphates insecticides.
    [show abstract] [hide abstract]
    ABSTRACT: In this paper, Au-TiO2/Chit modified electrode was prepared with Au-TiO2 nanocomposite (Au-TiO2) and Chitosan (Chit) as a conjunct. The Au-TiO2 nanocomposite and the films were characterized by electrochemical and spectroscopy methods. A set of experimental conditions was also optimized for the film's fabrication. The electrochemical and electrocatalytic behaviors of Au-TiO2/Chit modified electrode to trace organophosphates (OPs) insecticides such as parathion were discussed in this work. By differential pulse voltammetry (DPV) measurement, the current responses of Au-TiO2/Chit modified electrode were linear with parathion concentration ranging from 1.0 ng/ml to 7.0 x 10(3)ng/ml with the detection limit of 0.5 ng/ml. In order to evaluate the performance of the detection system, we also examined the real samples successfully in this work. It exhibited a sensitive, rapid and easy-to-use method for the fast determination of trace OPs insecticides.
    Talanta 08/2008; 76(4):758-62. · 3.79 Impact Factor
  • Article: Amperometric Biosensor Based on Immobilization Acetylcholinesterase on Manganese Porphyrin Nanoparticles for Detection of Trichlorfon with Flow‐Injection Analysis System
    [show abstract] [hide abstract]
    ABSTRACT: A highly sensitive amperometric biosensor for the detection of organophosphate pesticides (OPs) is developed. The biosensor was fabricated by immobilized acetylcholinesterase (AChE) on manganese (III) meso-tetraphenylporphyrin (MnTPP) nanoparticles (NPs)-modified glassy carbon (GC) electrode. The MnTPP NPs used in this article were synthesized by mixing solvent techniques. AChE enzyme was immobilized on the MnTPP NPs surface by conjugated with chitosan (CHIT). The electrocatalytic activity of MnTPP NPs led to a greatly improved performance for thiocholine (TCh) product detection. The developed AChE-CHIT/MnTPPNP/GC biosensor integrated with a flow-injection analysis (FIA) system was used to monitor trichlorfon (typical OP). A wide linear inhibition response for trichlorfon is observed in the range of 1.0 nM–1.0 mM, corresponding to 10–83% inhibition for AChE with a detection limit of 0.5 nM.
    Electroanalysis 12/2007; 19(24):2551 - 2557. · 2.87 Impact Factor
  • Article: Amperometric Sensor Based on Neutral Red‐Doped Silica Nanoparticles Coupled with Microdialysis for the Measurement of Glutamate in the Rat Striatum
    [show abstract] [hide abstract]
    ABSTRACT: Amperometric sensor based on neutral red-doped silica (NRSiO2) nanoparticles (NPs) was fabricated and coupled with a microdialysis sampling system for the detection of glutamate (Glu) in the rat striatum. The NRSiO2 NPs [about (45±3) nm] were prepared with water-in-oil (W/O) microemulsion method, and characterized by transmission electron microscope (TEM) technique. The neutral red (NR) doped in silica network could maintain its high electroactivity and behave as an excellent electron mediator for electrocatalysis of hydrogen dioxide. Furthermore, the silica surface could prevent the leakage of NR, hence, the stability of biosensor was improved. The novel Glu biosensor showed a linear range from 5.0×10−7 to 1.5×10−4 mol/L, with a detection limit of 2.0×10−7 mol/L(S/N3).
    Chinese Journal of Chemistry 07/2007; 25(7):953 - 957. · 0.75 Impact Factor
  • Article: Development of Quantum Dots Modified Acetylcholinesterase Biosensor for the Detection of Trichlorfon
    [show abstract] [hide abstract]
    ABSTRACT: Poly (N-vinyl-2-pyrrolidone) (PVP)-capped CdS quantum dots (QCdS-PVP) was synthesized with CdCl2 and Na2S in the presence of PVP. QCdS-PVP has been used for the immobilization and stabilization of the acetylcholinesterase (AChE). The electrocatalytic activity of QCdS-PVP leads to a greatly improved electrochemical detection of the enzymatically generated thiocholine product, and higher sensitivity and stability. The GCE/QCdS-PVP/AChE biosensor was used for the detection of organophosphate pesticides (OPs), such as trichlorfon. The sensor performance, including pH and inhibition time, was optimized with respect to operating conditions. Under the optimal conditions, the biosensor was used to measure as low as 12 ppb trichlorfon with a 5-min inhibition time.
    Electroanalysis 11/2006; 18(22):2163 - 2167. · 2.87 Impact Factor