[show abstract]
[hide abstract]
ABSTRACT: We recently used micro attenuated total reflection infrared (ATR-IR) spectroscopy to conduct imaging analysis of ointments and evaluate the distributions of the active pharmaceutical ingredient (API) and excipients. An alclometasone dipropionate (ALC) ointment was used as a model product. Almeta, a brand-name product, had a domain with absorbance at 1656 cm(-1) attributable to the carbonyl group of ALC, the API. Absorbances at 1040 and 3300 cm(-1) were also noted in this domain, indicating the presence of the solubilizer, propylene glycol. Data also suggested the presence of benzyl alcohol in this domain. More detailed analysis showed the distribution of surfactants and other excipients in the base. Similar results were obtained for Vitra, a generic version of Almeta. Imaging analysis with micro ATR-IR confirmed that both ointments are liquid droplet dispersions with ALC dissolved in propylene glycol and dispersed in a base. However, minor differences in the ingredient distributions of the two ointments were detected and reflect differences in excipient concentrations and type, or manufacturing differences. In summary, we used micro ATR-IR for imaging analysis of an original ointment, Almeta, and its generic form Vitra, and established a method for visually evaluating the distributions of the API and excipients in these ointments.
International journal of pharmaceutics 04/2012; 426(1-2):54-60. · 2.96 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: We used near infrared (NIR) spectroscopy to evaluate the degree of mixing of blended dry syrup (DS) products whose particle sizes are not specified in the Revised 16th Edition of the Japanese Pharmacopoeia, and also evaluated the degree of mixing when powder products or fine granule products were added to DS products. The data obtained were used to investigate the relationship between the particle size distributions of the products studied and the degree of mixing. We found that the particle size distribution characteristics of the 15 DS products studied can be broadly classified into 5 types. Combinations of frequently prescribed products were selected to represent 4 of the 5 particle size distribution types and were blended with a mortar and pestle. The coefficient of variation (CV) decreased as the percent mass of Asverin® Dry Syrup 2% (Asverin-DS) increased in blends of Periactin® Powder 1% (Periactin) and Asverin-DS, indicating an improved degree of mixing (uniformity). In contrast, in blends of Periactin and Mucodyne® DS 33.3%, mixing a combination at a 1:1 mass ratio 40 times resulted in a CV of 20%. Other mixing frequencies and mass ratios resulted in a CV by 50% to 70%, indicating a very poor degree of mixing (poor uniformity). These results suggest that when combining different DSs, or a DS with a powder or fine granule product, the blending obtained with a mortar and pestle improves as the particle size distributions of the components approach each other and as the ranges of the distributions narrow.
Chemical & pharmaceutical bulletin 01/2012; 60(5):624-31. · 1.70 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: We previously reported a strong positive correlation between syrup viscosity and the rate of syrup loss due to adhesion to a glass metering device. In this study, we examined differences in the surface free energies of metering devices made of different polymeric materials, since reducing adhesion loss to metering devices could improve the efficiency of drug preparation involving highly viscous syrups. Among metering devices made of glass only, glass with a silicone coating (SLC), polypropylene (PP), and polymethylpentene (PMP) the surface free energy of the glass-only metering device was the highest (49.2 mN/m). The adhesion loss obtained for highly viscous syrups in the PP and PMP metering devices was significantly lower than that of the glass metering device. Measurements of syrup contact angles suggested that in metering devices made of PP and PMP, which have low surface free energies, a decrease in the spreading wetting of syrups was a factor in reducing the rate of adhesion loss. Thus irrespective of the syrup viscosity being measured, metering devices produced from materials with low surface free energies can reduce the time required to prepare prescriptions without compromising the accuracy of drug preparation.
Yakugaku zasshi journal of the Pharmaceutical Society of Japan 08/2010; 130(8):1085-91. · 0.39 Impact Factor