Publications (2)6.14 Total impact
-
Article: Socioeconomic impact on device-associated infections in pediatric intensive care units of 16 limited-resource countries: international Nosocomial Infection Control Consortium findings.
[show abstract] [hide abstract]
ABSTRACT: We report the results of the International Nosocomial Infection Control Consortium prospective surveillance study from January 2004 to December 2009 in 33 pediatric intensive care units of 16 countries and the impact of being in a private vs. public hospital and the income country level on device-associated health care-associated infection rates. Additionally, we aim to compare these findings with the results of the Centers for Disease Control and Prevention National Healthcare Safety Network annual report to show the differences between developed and developing countries regarding device-associated health care-associated infection rates. A prospective cohort, active device-associated health care-associated infection surveillance study was conducted on 23,700 patients in International Nosocomial Infection Control Consortium pediatric intensive care units. The protocol and methodology implemented were developed by International Nosocomial Infection Control Consortium. Data collection was performed in the participating intensive care units. Data uploading and analyses were conducted at International Nosocomial Infection Control Consortium headquarters on proprietary software. Device-associated health care-associated infection rates were recorded by applying Centers for Disease Control and Prevention National Healthcare Safety Network device-associated infection definitions, and the impact of being in a private vs. public hospital and the income country level on device-associated infection risk was evaluated. None. Central line-associated bloodstream infection rates were similar in private, public, or academic hospitals (7.3 vs. 8.4 central line-associated bloodstream infection per 1,000 catheter-days [p < .35 vs. 8.2; p < .42]). Central line-associated bloodstream infection rates in lower middle-income countries were higher than low-income countries or upper middle-income countries (12.2 vs. 5.5 central line-associated bloodstream infections per 1,000 catheter-days [p < .02 vs. 7.0; p < .001]). Catheter-associated urinary tract infection rates were similar in academic, public and private hospitals: (4.2 vs. 5.2 catheter-associated urinary tract infection per 1,000 catheter-days [p = .41 vs. 3.0; p = .195]). Catheter-associated urinary tract infection rates were higher in lower middle-income countries than low-income countries or upper middle-income countries (5.9 vs. 0.6 catheter-associated urinary tract infection per 1,000 catheter-days [p < .004 vs. 3.7; p < .01]). Ventilator-associated pneumonia rates in academic hospitals were higher than private or public hospitals: (8.3 vs. 3.5 ventilator-associated pneumonias per 1,000 ventilator-days [p < .001 vs. 4.7; p < .001]). Lower middle-income countries had higher ventilator-associated pneumonia rates than low-income countries or upper middle-income countries: (9.0 vs. 0.5 per 1,000 ventilator-days [p < .001 vs. 5.4; p < .001]). Hand hygiene compliance rates were higher in public than academic or private hospitals (65.2% vs. 54.8% [p < .001 vs. 13.3%; p < .01]). Country socioeconomic level influence device-associated infection rates in developing countries and need to be considered when comparing device-associated infections from one country to another.Pediatric Critical Care Medicine 05/2012; 13(4):399-406. · 3.13 Impact Factor -
Article: International Nosocomial Infection Control Consortium (INICC) report, data summary for 2003-2008, issued June 2009.
[show abstract] [hide abstract]
ABSTRACT: We report the results of the International Infection Control Consortium (INICC) surveillance study from January 2003 through December 2008 in 173 intensive care units (ICUs) in Latin America, Asia, Africa, and Europe. During the 6-year study, using Centers for Disease Control and Prevention (CDC) US National Healthcare Safety Network (NHSN; formerly the National Nosocomial Infection Surveillance system [NNIS]) definitions for device-associated health care-associated infection, we collected prospective data from 155,358 patients hospitalized in the consortium's hospital ICUs for an aggregate of 923,624 days. Although device utilization in the developing countries' ICUs was remarkably similar to that reported from US ICUs in the CDC's NHSN, rates of device-associated nosocomial infection were markedly higher in the ICUs of the INICC hospitals: the pooled rate of central venous catheter (CVC)-associated bloodstream infections (BSI) in the INICC ICUs, 7.6 per 1000 CVC-days, is nearly 3-fold higher than the 2.0 per 1000 CVC-days reported from comparable US ICUs, and the overall rate of ventilator-associated pneumonia (VAP) was also far higher, 13.6 versus 3.3 per 1000 ventilator-days, respectively, as was the rate of catheter-associated urinary tract infection (CAUTI), 6.3 versus 3.3 per 1000 catheter-days, respectively. Most strikingly, the frequencies of resistance of Staphylococcus aureus isolates to methicillin (MRSA) (84.1% vs 56.8%, respectively), Klebsiella pneumoniae to ceftazidime or ceftriaxone (76.1% vs 27.1%, respectively), Acinetobacter baumannii to imipenem (46.3% vs 29.2%, respectively), and Pseudomonas aeruginosa to piperacillin (78.0% vs 20.2%, respectively) were also far higher in the consortium's ICUs, and the crude unadjusted excess mortalities of device-related infections ranged from 23.6% (CVC-associated bloodstream infections) to 29.3% (VAP).American journal of infection control 03/2010; 38(2):95-104.e2. · 3.01 Impact Factor