Are you Herbert Gluch?

Claim your profile

Publications (2)2.62 Total impact

  • Article: Cotrel-dubousset instrumentation for the correction of adolescent idiopathic scoliosis. Long-term results with an unexpected high revision rate.
    Franz J Mueller, Herbert Gluch
    [show abstract] [hide abstract]
    ABSTRACT: For many years, the CD instrumentation has been regarded as the standard device for the surgical correction of adolescent idiopathic scoliosis (AIS). Nevertheless, scientific long-term results on this procedure are rare. Therefore, we conducted a retrospective follow-up study of patients treated for AIS with CD instrumentation and spondylodesis. A total of 40 patients with AIS underwent CD instrumentation in our department within 3 years and between 1990 and 1992. For the retrospective analysis, first all the patient documents were reviewed, and pre-/postoperative X-ray images as well as those at the latest follow-up were analysed. Furthermore, it was attempted to conduct a clinical survey using the SRS-24 questionnaire, which was sent to the patients after a preceding announcement on the phone. Radiologically, the frontal main curvature was improved from a preoperative angle of 69.2° to a postoperative angle of 35.4°, and the secondary curvature was improved from a preoperative angle of 42.6° to a postoperative angle of 20.5°. The latest radiological follow-up at average 57.4 months post surgery showed an average loss of correction of 9.6° (main curvature) and 4.6° (secondary curvature), respectively.Within the first 30 days post surgery, 3 out of 40 patients (7.5%) received early operative revision for the dislocation of hooks or rods.At an average of 45.7 months (range 11 to 142 months), 19 out of 40 patients (47.5%; including 2 patients with early revision) received late operative revisions: The reasons were late infection (10 out of 40 patients; 25%) with the development of fistulae (7 cases) or putrid secretion (3 cases), which was resolved with the complete removal of instrumentation after all. The average time until revision was 35.5 months (range 14 to 56 months) after CD instrumentation. Furthermore, complete implant removal was necessary in 8 out of 40 patients (20%) for late operate site pain (LOSP). The average time until removal of instrumentation was 62.7 months (range 18 to 146 months) post surgery; and one patient received partial device removal for prominent instrumentation 11 months post surgery. Altogether, only 22 out of 40 CD instrumentations (55%) were still in situ.After an average period of 14.3 years post surgery, it was possible to follow-up 14 out of 40 patients (35%) using the SRS-24 questionnaire. The average score was 93 points, without showing significant differences between patients with or without their instrumentation in situ. Retrospectively, we documented for the first time a very high revisions rate in patients with AIS and treated by CD instrumentation. Nearly half of the instrumentation had to be removed due to late infection and LOSP. The reasons for the high rate of late infections with or without fistulae and for LOSP were analysed and discussed in detail.
    Scoliosis 06/2012; 7(1):13. · 1.31 Impact Factor
  • Source
    Article: Adolescent idiopathic scoliosis (AIS) treated with arthrodesis and posterior titanium instrumentation: 8 to 12 years follow up without late infection.
    Franz J Mueller, Herbert Gluch
    [show abstract] [hide abstract]
    ABSTRACT: There are no data in the peer-reviewed literature regarding long term results in patients treated for AIS with a posterior titanium instrumentation. Therefore we assessed the outcome in 50 patients treated by titanium implant. A total of 50 patients with a mean age of 16.6 years were treated. In all patients, titanium hooks and pedicle screws were used in combination. The demographic data and the pre- and post-operative radiographs of all 50 patients were re-examined, and 49 of the 50 patients (98%) attended a radiological and clinical follow up-examination on average 10.1 years post-operatively. The clinical results were recorded by means of the SRS 24 questionnaire. In the frontal plane, the mean pre-operative thoracic and lumbar curve had been 62.4 degrees and 43.5 degrees respectively, post-operatively the curves were reduced to 26.9 degrees and 16.3 degrees , resulting in a correction rate of 56.9% for thoracic and 62.5% for lumbar curve. At the follow up-evaluation, the Cobb angle of the thoracic and lumbar curve was 31.0 degrees and 21.3 degrees respectively, giving a final correction rate of 50.3% for thoracic, and 51.0% for lumbar curve. 7 of the 50 patients (14.3%) had undergo revision surgery for complications, but complete implant removal was necessary in only one case. Analysis of the SRS 24 questionnaire showed an average score of 95.8 points. Posterior titanium instrumentation is a safe and effective procedure in the surgical correction of AIS. In this retrospective study with small patient number, it shows favourable long-term results; in particular, the loss of correction is low, no late infection occurred and there was a very high survival rate of the implant itself.
    Scoliosis 09/2009; 4:16. · 1.31 Impact Factor

Top co-authors

Top Journals

Institutions