-
[show abstract]
[hide abstract]
ABSTRACT: A 57-year old male underwent elective aortic valve replacement. The immediate post-operative course was uneventful and the patient was discharged with the lowest possible score on a newly implemented scale for early detection of critical illness. The following day he was readmitted with dyspnoea. The critical illness score was still low despite ultrasonic demonstration of a large pericardial effusion requiring drainage. We are concerned that the widely adopted critical illness scale is not sufficiently sensitive for cardiac surgery patients and advocate the use of point-of-care ultrasound.
Ugeskrift for laeger 02/2013; 175(8):486-487.
-
Anesthesia and analgesia 10/2012; 115(5):1029-32. · 3.08 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: Previous studies addressing teaching and learning in point-of-care ultrasound have primarily focussed on image interpretation and not on the technical quality of the images. We hypothesized that a limited intervention of 10 supervised examinations would improve the technical skills in Focus Assessed Transthoracic Echocardiography (FATE) and that physicians with no experience in FATE would quickly adopt technical skills allowing for image quality suitable for interpretation.
Twenty-one physicians with no previous training in FATE or echocardiography (Novices) participated in the study and a reference group of three examiners with more than 10 years of experience in echocardiography (Experts) was included. Novices received an initial theoretical and practical introduction (2 hours), after which baseline examinations were performed on two healthy volunteers. Subsequently all physicians were scheduled to a separate intervention day comprising ten supervised FATE examinations. For effect measurement a second examination (evaluation) of the same two healthy volunteers from the baseline examination was performed.
At baseline 86% of images obtained by novices were suitable for interpretation, on evaluation this was 93% (p = 0.005). 100% of images obtained by experts were suitable for interpretation. Mean global image rating on baseline examinations was 70.2 (CI 68.0-72.4) and mean global image rating after intervention was 75.0 (CI 72.9-77.0), p = 0.0002. In comparison, mean global image rating in the expert group was 89.8 (CI 88.8-90.9).
Improvement of technical skills in FATE can be achieved with a limited intervention and upon completion of intervention 93% of images achieved are suitable for clinical interpretation.
BMC Medical Education 08/2012; 12:65. · 1.15 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: The myocardial recovery time following on-pump cardiac surgery remains uncertain. Global peak longitudinal strain is a sensitive measure of endocardial function which is most susceptible to ischaemia. We aimed to evaluate changes in global peak longitudinal strain up to 6 months after surgery and to compare initial changes with alterations in troponin T. Secondarily, we aimed to describe perioperative changes in strain of the inter-ventricular septum when compared with reference segments.
Patients scheduled for coronary bypass, aortic valve replacement or combination procedures were enrolled. Echocardiography was performed on the day before surgery, the day after surgery, 4 days after surgery, 30 days after surgery and 6 months after surgery. Troponin T was measured 3, 16 and 24 h following procedure.
Forty patients were enrolled and one was later excluded. Global peak longitudinal strain decreased from -14.5 ± 3.33% preoperatively to -9.98 ± 3.09% and -10.57 ± 3.16% on the first and fourth postoperative day, respectively. Global strain was still reduced on the 30th postoperative day, but had returned to preoperative values 6 months after surgery. Absolute values and relative changes in global strain did not correlate with postoperative peak troponin T measurements. Strain of the inter-ventricular septum was unaffected by surgery as opposed to reference segments, although septal displacement in the longitudinal direction decreased from 12.0 ± 3.75 mm preoperatively to 3.58 ± 4.22 mm 4 days after surgery.
Global peak longitudinal strain was reduced for at least 30 days after on-pump cardiac surgery and seems to represent a more sensitive marker of myocardial function than ejection fraction. The decrease in global strain was not reflected in troponin T measurements. The visual, echocardiographic impression of septal dysfunction may be a translational phenomenon, as septal strain was unaffected by surgery.
Interactive cardiovascular and thoracic surgery 06/2012; 15(3):395-9.
-
[show abstract]
[hide abstract]
ABSTRACT: Advances in medical ultrasound have made the modality widely applicable and the new cart-based and pocket size devices have allowed for relevant point-of-care (POC) ultrasound examinations in many medical specialties. POC ultrasonography is performed as a real-time examination assisting the physician in diagnosis, procedure or screening of the patient without life threatening delays. The examination can be performed at the bedside or wherever the patient may be present. Structured and focused protocols for simple clinical questions have been developed and implemented in the following specialties: Anesthesiology, Cardiology, Critical Care Medicine, Dermatology, Emergency Medicine, Neonatology, Gynecology and Rheumatology and many others. POC ultrasound, as well as ultrasound in general, is very user dependent and the need for quality assurance, formal education and practical training is obvious. With this in mind, POC ultrasound now really has the potential for becoming the physician's new personal universal examination tool. Patients admitted to emergency departments will be able to receive organ or symptom-guided initial focused ultrasound triage as part of the physician's first encounter with the patient. This will allow for more accurate referral, correct diagnosis and relevant screening in turn leading to better overall treatment results.
Expert Opinion on Medical Diagnostics 05/2012; 6(3):167-170.
-
Cardiology research and practice. 01/2012; 2012:961423.
-
[show abstract]
[hide abstract]
ABSTRACT: Background. The use of echocardiography in intensive care settings impacts decision making. A prerequisite for the use of echocardiography is relative resistance to changes in volume status and levels of positive pressure ventilation (PPV). Studies on indices of diastolic function report conflicting results with regard to dependence on volume status. Evidence is scarce on PPV. Methods. Ten healthy subjects were exposed to 6 levels of positive end-expiratory pressure (PEEP) and pressure support (PS) following a baseline reading. All ventilator settings were performed at three positions: horizontal, reverse-Trendelenburg, and Trendelenburg. Echocardiography was performed throughout. Results. During spontaneous breathing, early diastolic transmitral velocity (E) changed with positioning (P < 0.001), whereas early diastolic velocity of the mitral annulus (e') was independent (P = 0.263). With PPV, E and e' proved preload dependent (P values < 0.001). Increases in PEEP, PS, or a combination influenced E and e' in reverse-Trendelenburg- and horizontal positions, but not in the Trendelenburg position. Discussion. The change towards preload dependency of e' with PPV suggests that PPV increases myocardial preload sensitivity. The susceptibility of E and e' to preload changes during PPV discourages their use in settings of volume shifts or during changes in ventilator settings. Conclusion. Positioning and PPV affect E and e'.
Critical care research and practice 01/2012; 2012:703196.
-
[show abstract]
[hide abstract]
ABSTRACT: The authors hypothesized that preoperative N-terminal probrain natriuretic peptide (NT-proBNP) correlates well with longitudinal strain measurements and with Doppler measurements of diastolic function.
Prospective observational study.
University teaching hospital.
Forty patients undergoing elective cardiac surgery.
Aortic valve replacement, coronary artery bypass grafting, or a combination of these procedures.
Plasma NT-proBNP concentration was obtained by analyzing blood samples with a commercially available kit. Left ventricular systolic function was assessed by speckle tracking ultrasound strain measurements and left ventricular diastolic function was assessed by 2 Doppler methods: E/A ratio and E/E' ratio. Tissue Doppler imaging velocities (E' and A') were measured in the basal septum (annular) and pulse-wave Doppler was used to measure mitral in-flow profile (E and A). The correlation between global strain data from the speckle tracking ultrasound measurement and NT-proBNP levels was ρ = 0.35 (p = 0.026). With a cutoff value of -15% in global strain measurements, there was a significant difference in NT-proBNP levels (117 v 57 pg/mL, p = 0.048). E/E' values correlated with NT-proBNP levels (ρ = 0.46, p = 0.011). With a cutoff of 15 in E/E' values, there were significant differences in corresponding NT-proBNP levels (33 v 113 pg/mL, p = 0.004).
A correlation was found between plasma levels of NT-proBNP and speckle tracking ultrasound strain measurements by an easily employed method applicable in the anesthesia and preoperative settings. In addition, the well-established marker of diastolic function, E/E', correlated well with NT-proBNP, whereas the E/A ratio failed to show any association.
Journal of cardiothoracic and vascular anesthesia 09/2011; 26(2):197-203. · 1.06 Impact Factor
-
Ugeskrift for laeger 08/2010; 172(35):2403; author reply 2403.
-
[show abstract]
[hide abstract]
ABSTRACT: The aim of the study was to compare the diameter response of retinal arterioles and retinal thickness in patients with different stages of diabetic maculopathy during an increase in the arterial blood pressure.
Four groups each consisting of 19 individuals were studied. Group A consisted of normal individuals and groups B-D consisted of type 2 diabetic patients matched for diabetes duration, age, and gender, and characterized by: Group B no retinopathy, Group C mild retinopathy, Group D maculopathy not requiring laser treatment. The diameter changes of a large retinal arteriole were measured using the Retinal Vessel Analyzer (RVA, Imedos, Germany) before, during, and after an increase in the blood pressure induced by isometric exercise. Additionally, the retinal thickness was measured using optical coherence tomography scanning.
The arterioles contracted during isometric exercise in normal persons (diameter response: -0.70+/-0.48%) and in patients with no retinopathy (-1.15+/-0.44%), but dilated in patients with mild retinopathy (0.41+/-0.49%) and diabetic maculopathy (0.54+/-0.44%), p=0.01. Retinal thickness was normal in Group A (260+/-5.0 microm), Group B (257+/-4.5 microm), and Group C (253+/-4.4 microm), but was significantly (p=0.006) increased in Group D (279+/-5.3 microm).
The diameter response was reduced in type 2 diabetic patients with retinopathy, whereas retinal thickness was increased in patients with diabetic maculopathy. This suggests that impairment of diameter response in retinal arterioles precedes the development of diabetic macular edema.
Albrecht von Graæes Archiv für Ophthalmologie 11/2006; 244(10):1255-61. · 2.17 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: Reduced diurnal blood pressure (BP) variation ("non-dipping") is associated with both micro- and macrovascular complications in patients with type 2 diabetes. The relation between endothelial perturbation and diurnal BP variation in diabetic subjects has not previously been studied. Seventy-six subjects, stratified to 4 gender-, age-, and duration-matched groups of 19 subjects each, were studied (group A: non-diabetic subjects; group B to D, type 2 diabetic subjects; group B: no retinopathy; group C: minimal background retinopathy; group D: diabetic maculopathy). All subjects underwent a 24-hour ambulatory BP monitoring. von Willebrand factor (vWF), fibrinogen, E-selectin, and intercellular adhesion molecule-1 were measured in plasma. Systolic night/day BP ratio increased gradually in groups A to D: 85.2 +/- 5%, 85.7 +/- 7%, 88.5 +/- 6%, and 90.5 +/- 7%, respectively, P < .05. Among diabetic patients, non-dippers had significantly higher plasma levels of vWF and fibrinogen than dippers (median/interquartile range 1.7/1.4 to 2.1 vs. 1.2/0.9 to 1.5 U/mL, P < .01 and 3.6/3.6 to 3.7 vs. 2.9/2.5 to 3.6 g/L, P = .01). Non-dipping is associated with elevated plasma levels of proteins related to endothelial cell activation as well as with retinopathy in subjects with type 2 diabetes. This finding suggests a possible mechanism linking non-dipping with microvascular complications in these subjects.
Journal of the American Society of Hypertension 1(3):208-15. · 2.12 Impact Factor