-
[show abstract]
[hide abstract]
ABSTRACT: Isobaric mass tag-based quantitative proteomics strategies such as iTRAQ and TMT utilize reporter ions in the low-mass range of tandem MS spectra for relative quantification. The number of samples that can be compared in a single experiment (multiplexing) is limited by the number of different reporter ions that can be generated by differential stable isotope incorporation ((15)N, (13)C) across the reporter and the mass balancing parts of the reagents. Here, we demonstrate that a higher multiplexing rate can be achieved by utilizing the 6 mDa mass difference between (15)N- and (13)C-containing reporter fragments, in combination with high-resolution mass spectrometry. Two variants of the TMT127 and TMT129 reagents are available; these are distinguished by the position and the nature of the incorporated stable isotope in the reporter portions of the labels (TMT127L, (12)C(8)H(16)(15)N(1)(+); TMT127H, (12)C(7)(13)C(1)H(16)(14)N(1)(+); TMT129L, (12)C(6)(13)C(2)H(16)(15)N(1)(+); and TMT129H, (12)C(5)(13)C(3)H(16)(14)N(1)(+)). We demonstrate that these variants can be baseline-resolved in Orbitrap Elite higher-energy collision-induced dissociation spectra recorded with a 96 ms transient enabling comparable dynamic range, precision, and accuracy of quantification as 1 Da spaced reporter ions. The increased multiplexing rate enabled determination of inhibitor potencies in chemoproteomic kinase assays covering a wider range of compound concentrations in a single experiment, compared to conventional 6-plex TMT-based assays.
Analytical Chemistry 08/2012; 84(16):7188-94. · 5.86 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: Fragmentation of multiple peptides in a single tandem mass scan impairs accuracy of isobaric mass tag based quantification. Consequently, practitioners aim at fragmenting peptide ions with the highest possible purity without compromising on sensitivity and coverage achieved in the experiment. Here we report the first systematic study optimizing delayed fragmentation options on Orbitrap instruments. We demonstrate that by delaying peptide fragmentation to occur closer to the apex of the chromatographic peak in liquid chromatography-tandem mass spectrometry (LC-MS/MS) experiments cofragmentation is reduced by 2-fold and peptides are fragmented with 2.8-fold better signal-to-noise ratios. This results in significantly improved accuracy of isobaric mass tag quantification. Further, we measured cofragmentation dependence on isolation width. In comparison to Orbitrap XL instruments the reduced space charging in the Orbitrap Velos enables isolation widths as narrow as 1 Th without impairing coverage, thus substantially reducing cofragmentation. When delayed peptide fragmentation and narrow isolation width settings were both applied, cofragmentation-induced ratio compression could be reduced by 32% on a log2 scale under otherwise identical conditions.
Analytical Chemistry 12/2011; 83(23):8959-67. · 5.86 Impact Factor
-
Marcus Bantscheff,
Carsten Hopf,
Mikhail M Savitski,
Antje Dittmann,
Paola Grandi,
Anne-Marie Michon,
Judith Schlegl,
Yann Abraham,
Isabelle Becher,
Giovanna Bergamini, [......],
Carola Huthmacher,
Toby Mathieson,
Daniel Poeckel,
Valérie Reader,
Katja Strunk, Gavain Sweetman,
Ulrich Kruse,
Gitte Neubauer,
Nigel G Ramsden,
Gerard Drewes
[show abstract]
[hide abstract]
ABSTRACT: The development of selective histone deacetylase (HDAC) inhibitors with anti-cancer and anti-inflammatory properties remains challenging in large part owing to the difficulty of probing the interaction of small molecules with megadalton protein complexes. A combination of affinity capture and quantitative mass spectrometry revealed the selectivity with which 16 HDAC inhibitors target multiple HDAC complexes scaffolded by ELM-SANT domain subunits, including a novel mitotic deacetylase complex (MiDAC). Inhibitors clustered according to their target profiles with stronger binding of aminobenzamides to the HDAC NCoR complex than to the HDAC Sin3 complex. We identified several non-HDAC targets for hydroxamate inhibitors. HDAC inhibitors with distinct profiles have correspondingly different effects on downstream targets. We also identified the anti-inflammatory drug bufexamac as a class IIb (HDAC6, HDAC10) HDAC inhibitor. Our approach enables the discovery of novel targets and inhibitors and suggests that the selectivity of HDAC inhibitors should be evaluated in the context of HDAC complexes and not purified catalytic subunits.
Nature Biotechnology 01/2011; 29(3):255-65. · 29.50 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: Here we describe a set of enhanced data processing and filtering methods to improve significance and coverage of phosphopeptide identifications by mass spectrometry. We demonstrate that for samples of limited complexity, spectra-based estimation of false discovery rates will lead to overprediction of confidently identified phosphorylated peptides due to a bias caused by multiple fragmentation of highly abundant peptide species. We further provide evidence that fragmentation of abundant peptides at the tails of their chromatographic peaks is a major source for false positive peptide matches and that overall confidence in phosphopeptide identifications can be improved by a chromatographic peak-based aggregation scheme, intensity rank-based neutral loss and optimized mass error filters. When replicate runs of a standard sample were performed using different fragmentation techniques on an Orbitrap mass spectrometer we observed improvements of 7-31% in phosphopeptide coverage depending on the fragmentation method and the desired false discovery rate.
Analytical Chemistry 10/2010; 82(23):9843-9. · 5.86 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: Quantitative mass spectrometry-based proteomic assays often suffer from a lack of robustness and reproducibility. We here describe a targeted mass spectrometric data acquisition strategy for affinity enriched subproteomes-in our case the kinome-that enables a substantially improved reproducibility of detection, and improved quantification via isobaric tags. Inclusion mass lists containing m/z, charge state, and retention time were created based on a set of 80 shotgun-type experiments performed under identical experimental conditions. For each target protein, peptides were selected according to their frequency of observation and isobaric tag for relative and absolute quantitation (iTRAQ) reporter ion quality. Retention times of selected peptides were aligned using similarity driven pairwise alignment strategy yielding <1 min standard deviation for 4 h gradients. Multiple fragmentation of the same peptides resulted in better statistics and more precise reporter ion based quantification without any loss in coverage. Overall, 24% more target proteins were quantified using the targeted data acquisition approach, and precision of quantification improved by >1.5-fold. We also show that a combination of higher energy collisional dissociation (HCD) with collisional induced dissociation (CID) outperformed pulsed-Q-dissociation (PQD) on the OrbitrapXL. With the CID/HCD based targeted data acquisition approach 10% more quantifiable target proteins were identified and a 2-fold increase in quantification precision was achieved. We have observed excellent reproducibility between different instruments, underlining the robustness of the approach.
Journal of the American Society for Mass Spectrometry 01/2010; 21(10):1668-79. · 4.00 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: Isobaric stable isotope tagging reagents such as tandem mass tags or isobaric tags for relative and absolute quantification enable multiplexed quantification of peptides via reporter ion signals in the low mass range of tandem mass spectra. Until recently, the poor recovery of low mass fragments observed in tandem mass spectra acquired on ion trap mass spectrometers precluded the use of these reagents on this widely available instrument platform. The Pulsed Q Dissociation (PQD) technique allows negotiating this limitation but suffers from poor fragmentation efficiency, which has raised doubts in the community as to its practical utility. Here we show that by carefully optimizing instrument parameters such as collision energy, activation Q, delay time, ion isolation width, number of microscans, and number of trapped ions, low m/z fragment ion intensities can be generated that enable accurate peptide quantification at the 100 amol level. Side by side comparison of PQD on an LTQ Orbitrap with CID on a five-year old Q-Tof Ultima using complex protein digests shows that whereas precision of quantification of 10-15% can be achieved by both approaches, PQD quantifies twice as many proteins. PQD on an LTQ Orbitrap also outperforms "higher energy collision induced dissociation" on the same instrument using the recently introduced octapole collision cell in terms of lower limit of quantification. Finally, we demonstrate the significant analytical potential of iTRAQ quantification using PQD on an LTQ Orbitrap by quantitatively measuring the kinase interaction profile of the small molecule drug imatinib in K-562 cells. This article gives practical guidance for the implementation of PQD, discusses its merits, and for the first time, compares its performance to higher energy collision-induced dissociation.
Molecular & Cellular Proteomics 07/2008; 7(9):1702-13. · 7.40 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: The quantification of differences between two or more physiological states of a biological system is among the most important but also most challenging technical tasks in proteomics. In addition to the classical methods of differential protein gel or blot staining by dyes and fluorophores, mass-spectrometry-based quantification methods have gained increasing popularity over the past five years. Most of these methods employ differential stable isotope labeling to create a specific mass tag that can be recognized by a mass spectrometer and at the same time provide the basis for quantification. These mass tags can be introduced into proteins or peptides (i) metabolically, (ii) by chemical means, (iii) enzymatically, or (iv) provided by spiked synthetic peptide standards. In contrast, label-free quantification approaches aim to correlate the mass spectrometric signal of intact proteolytic peptides or the number of peptide sequencing events with the relative or absolute protein quantity directly. In this review, we critically examine the more commonly used quantitative mass spectrometry methods for their individual merits and discuss challenges in arriving at meaningful interpretations of quantitative proteomic data.
Analytical and Bioanalytical Chemistry 11/2007; 389(4):1017-31. · 3.78 Impact Factor
-
Marcus Bantscheff,
Dirk Eberhard,
Yann Abraham,
Sonja Bastuck,
Markus Boesche,
Scott Hobson,
Toby Mathieson,
Jessica Perrin,
Manfred Raida,
Christina Rau, [......], Gavain Sweetman,
Andreas Bauer,
Tewis Bouwmeester,
Carsten Hopf,
Ulrich Kruse,
Gitte Neubauer,
Nigel Ramsden,
Jens Rick,
Bernhard Kuster,
Gerard Drewes
[show abstract]
[hide abstract]
ABSTRACT: We describe a chemical proteomics approach to profile the interaction of small molecules with hundreds of endogenously expressed protein kinases and purine-binding proteins. This subproteome is captured by immobilized nonselective kinase inhibitors (kinobeads), and the bound proteins are quantified in parallel by mass spectrometry using isobaric tags for relative and absolute quantification (iTRAQ). By measuring the competition with the affinity matrix, we assess the binding of drugs to their targets in cell lysates and in cells. By mapping drug-induced changes in the phosphorylation state of the captured proteome, we also analyze signaling pathways downstream of target kinases. Quantitative profiling of the drugs imatinib (Gleevec), dasatinib (Sprycel) and bosutinib in K562 cells confirms known targets including ABL and SRC family kinases and identifies the receptor tyrosine kinase DDR1 and the oxidoreductase NQO2 as novel targets of imatinib. The data suggest that our approach is a valuable tool for drug discovery.
Nature Biotechnology 10/2007; 25(9):1035-44. · 23.27 Impact Factor