Publications (9)12.62 Total impact
-
Article: Cardiac MRI: evaluation of phonocardiogram-gated cine imaging for the assessment of global und regional left ventricular function in clinical routine.
[show abstract] [hide abstract]
ABSTRACT: To validate a phonocardiogram (PCG)-gated cine imaging approach for the assessment of left ventricular (LV) function. In this prospective study, cine MR imaging of the LV was performed twice in 79 patients by using retrospectively PCG- and retrospectively ECG-gated cine SSFP sequences at 1.5 T. End-diastolic volumes (EDV), end-systolic volumes (ESV), stroke volumes (SV), ejection fraction (EF), muscle mass (MM), as well as regional wall motion were assessed. Subgroup analyses were performed for patients with valvular defects and for patients with dysrhythmia. PCG-gated imaging was feasible in 75 (95%) patients, ECG-gating in all patients. Excellent correlations were observed for all volumetric parameters (r > 0.98 for all variables analysed). No significant differences were observed for EDV (-0.24 ± 3.14 mL, P = 0.5133), ESV (-0.04 ± 2.36 mL, P = 0.8951), SV (-0.20 ± 3.41 mL, P = 0.6083), EF (-0.16 ± 1.98%, P = 0.4910), or MM (0.31 ± 4.2 g, P = 0.7067) for the entire study cohort, nor for either of the subgroups. PCG- and ECG-gated cine imaging revealed similar results for regional wall motion analyses (115 vs. 119 segments with wall motion abnormalities, P = 0.3652). The present study demonstrates that PCG-gated cine imaging enables accurate assessment of global and regional LV function in the vast majority of patients in clinical routine. Phonocardiogram-gating is an alternative to electrocardiographic-gating in cardiac MR. Phonocardiogram-gated imaging allows reliable assessment of global and regional left-ventricular function. Phonocardiogram-gating is feasible in patients with valvular lesions or cardiac dysrhythmia. Because phonocardiogram-gating is insensitive to magneto-hydrodynamic effects, it is suitable for ultra-high field.European Radiology 09/2011; 22(3):559-68. · 3.22 Impact Factor -
Article: Elevation of high sensitive troponin T after CMR stress testing
Journal of Cardiovascular Magnetic Resonance. 01/2011; -
Article: CMR ventriculometry for evaluation of ecg hypertrophy criteria in a preventive medicine population
Journal of Cardiovascular Magnetic Resonance. 01/2011; -
Article: Single breath-hold magnetic resonance cine imaging for fast assessment of global and regional left ventricular function in clinical routine.
[show abstract] [hide abstract]
ABSTRACT: To evaluate a TGRAPPA (temporal parallel acquisition technique)-accelerated, single breath-hold multi-slice cine imaging approach for the assessment of left ventricular (LV) function. One hundred eleven patients were examined at 1.5 T. Cine imaging was performed with single-slice breath-hold acquisitions in short-axis orientation using a SSFP (TR 2.63 ms, TE 1.12 ms, FA 72°) sequence and a TGRAPPA SSFP (TR 2.66 ms, TE 1.11 ms, FA 72°, AF 3) sequence, which covered the entire LV in multiple short-axis slices during a single breath-hold. End-diastolic (EDV), end-systolic (ESV), stroke volumes (SV), ejection fraction (EF), muscle mass (MM) and regional wall motion were assessed for both data sets. Single breath-hold imaging was feasible in 108 patients. Excellent correlations were observed for all volumetric parameters derived from both data sets (all r > 0.97). While EDV and ESV showed marginally lower values for single breath-hold imaging (EDV: -1.6 ± 7.9 ml; ESV: -1.8 ± 6.0 ml, p < 0.05), no differences were observed for SV, EF, MM and regional wall motion assessment. Single breath-hold imaging required significant shorter acquisition times (28 ± 6 s vs. 335 ± 87 s). TGRAPPA-accelerated multi-slice SSPF imaging allows for fast and accurate assessment of regional and global LV function within a single breath-hold.European Radiology 10/2010; 20(10):2341-7. · 3.22 Impact Factor -
Article: CMR analysis of global and regional left ventricular function in a single breath-hold
Journal of Cardiovascular Magnetic Resonance. 01/2010; -
Article: A simple MR algorithm for estimation of myocardial salvage following acute ST segment elevation myocardial infarction.
[show abstract] [hide abstract]
ABSTRACT: To assess myocardial salvage in acute ST segment elevation myocardial infarction (STEMI) by using contrast-enhanced CMR. Forty-four consecutive patients (38 male; mean age 59 +/- 10 years) with a first acute STEMI underwent acute percutaneous coronary intervention with successful restoration of TIMI grade 3 flow. CMR was performed 2 +/- 1 days after reperfusion on a standard 1.5 T MR Scanner that included a steady-state free precession cine imaging for LV function and an inversion-recovery fast low angle shot (TR 8 ms, TE 4 ms, FA 25 degrees ) sequences for late gadolinium enhancement (LGE) following the injection of 0.2 mmol/kg BW gadodiamide. The myocardium at risk (MR) was approximated by the volume of myocardium exhibiting LGE and/or impaired wall motion. The myocardial salvage index (MSI) was calculated as the volume of the MR minus the volume of LGE divided by the volume of the MR. Reperfusion therapy was rated successful with an ST elevation resolution (STR) > or =70% and was considered inadequate below 70%. Infarct size (LGE) was 17 +/- 13% of LV mass, the mean STR was 53.4 +/- 28.3%, and the MSI was 10.9 +/- 6.2%. There was a good correlation between the MSI and the STR (r = 0.695, P < 0.0001). Thirty patients had an STR below 70%, and 14 patients had an STR greater than 70%. The MSI was greater in patients with a STE resolution of more than 70% (12 +/- 11 vs. 6 +/- 3%, P < 0.0001). A simple MR algorithm based upon the relationship of functional impairment, which includes myocardial stunning, to the extent of LGE (infarct necrosis) is in accordance with STR as a clinical marker of successful reperfusion in acute myocardial infarction.Clinical Research in Cardiology 09/2009; 98(10):651-6. · 2.95 Impact Factor -
Article: Rapid MR assessment of left ventricular systolic function after acute myocardial infarction using single breath-hold cine imaging with the temporal parallel acquisition technique (TPAT) and 4D guide-point modelling analysis of left ventricular function.
[show abstract] [hide abstract]
ABSTRACT: We compared four-dimensional guide-point modelling left ventricular function analysis (4DVF) results of cine images in four short-axis and two long-axis slices acquired in a single breath-hold, obtained with the temporal parallel acquisition technique (TPAT), with standard left ventricular function (LVF) analysis results determined by the summation of discs method, in patients who had recently suffered myocardial infarction. Despite wall motion abnormalities, 4DVF yields results for left ventricular ejection fractions and end-diastolic and end-systolic volumes that are in excellent agreement with standard LVF analysis results in these patients. A shortened cardiac magnetic resonance (CMR) protocol using single breath-hold cine image acquisition could facilitate the assessment of left ventricular function soon after myocardial infarction in critically ill patients who are unable to comply with the multiple breath-holds required for standard LVF analysis.European Radiology 08/2009; 20(1):73-80. · 3.22 Impact Factor -
Article: Cardiac magnetic resonance findings in asymptomatic patients with Brugada syndrome
Journal of Cardiovascular Magnetic Resonance. 01/2009; -
Article: Rapid MR assessment of left ventricular systolic function early after acute myocardial infarction using single breath-hold cine imaging with temporal parallel acquisition technique (TPAT) and 4D guide-point modeling
Journal of Cardiovascular Magnetic Resonance. 01/2009;
Top Journals
Institutions
-
2009–2010
-
Universitätsklinikum Essen
- Institut für Diagnostische und Interventionelle Radiologie und Neuroradiologie
Essen, North Rhine-Westphalia, Germany
-