Salvatore A Chiaramida
Publications of Salvatore A Chiaramida
CT detection of myocardial blood volume deficits: dual-energy CT compared with single-energy CT spectra.
Journal of cardiovascular computed tomography. 11/2011; 5(6):421-9.
The performance of dual-energy CT (DECT) for the detection of myocardial blood volume deficits has not systematically been compared with single-energy CT (SCT) spectra. We evaluated the accuracy for
Cost-effectiveness of substituting dual-energy CT for SPECT in the assessment of myocardial perfusion for the workup of coronary artery disease.
European journal of radiology. 01/2011;
PURPOSE: We compared cost-effectiveness and potential lifetime benefits of using dual-energy computed tomography (DECT) for myocardial perfusion assessment instead of single photon emission computed
Comparison of dual-energy computed tomography of the heart with single photon emission computed tomography for assessment of coronary artery stenosis and of the myocardial blood supply.
The American journal of cardiology. 09/2009; 104(3):318-26.
To evaluate the performance of dual-energy computed tomography (CT) for integrative imaging of the coronary artery morphology and the myocardial blood supply, 36 patients (15 women, mean age 57 +/-
Noncalcified atherosclerotic plaque burden at coronary CT angiography: a better predictor of ischemia at stress myocardial perfusion imaging than calcium score and stenosis severity.
AJR. American journal of roentgenology. 09/2009; 193(2):410-8.
OBJECTIVE: The purpose of this study was to examine the relation between the coronary CT angiographic findings of calcified and noncalcified plaque burden and stenosis severity and the myocardial
Dual-energy CT of the heart-Principles and protocols.
European journal of radiology. 12/2008;
The introduction of coronary CT angiography (cCTA) has reinvigorated the debate whether management of patients with suspected coronary artery disease (CAD) should be primarily based on physiological
Quantitative assessment of pericardial effusion volume by two-dimensional echocardiography.
Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 02/2003; 16(2):147-53.
The clinical applicability of a method for quantifying pericardial effusion (PE) was studied. The pericardial and cardiac volumes were determined from border tracings of 2-dimensional echocardiograms
Adenosine-stress dynamic myocardial volume perfusion imaging with second generation dual-source computed tomography: Concepts and first experiences.
Journal of cardiovascular computed tomography. 4(2):127-35.
Recent research suggests that multidetector-row CT may have potential as a standalone modality for integrative imaging of coronary heart disease, including the assessment of the myocardial blood
Are you Salvatore A Chiaramida?
Claim your profileCo-Authors of Salvatore A Chiaramida
Top Primary Authors
- Anita M Prakash (1)
- Florian Schwarz (1)
- Ralf W Bauer (1)
- Gorka Bastarrika (1)
- Balazs Ruzsics (1)
- Elisabeth Arnoldi (1)
- Mathias Meyer (1)
Top Secondary Authors
- Luis Ramos-Duran (1)
- Florian Schwarz (1)
- Christian Thilo (1)
- Yeong Shyan Lee (1)
- Balazs Ruzsics (1)
- John W Nance (1)
- Ying Sun (1)
Top Senior Authors
- U Joseph Schoepf (2)
- Peter L Zwerner (2)
- Richard J Lucariello (1)
- Thomas Henzler (1)
- Doo Kyoung Kang (1)
Top Journals
Keywords of Salvatore A Chiaramida
coronary artery disease
coronary CT angiographic findings
coronary CT angiography
CT angiography
dual-energy CT
myocardial perfusion imaging
negative predictive value
perfusion defects
perfusion imaging
predictive value
