Aaron K Grant

Beth Israel Deaconess Medical Center, Boston, MA, USA

Are you Aaron K Grant?

Claim your profile

Publications (13)32.07 Total impact

  • Article: Perfusion imaging with a freely diffusible hyperpolarized contrast agent.
    [show abstract] [hide abstract]
    ABSTRACT: Contrast agents that can diffuse freely into or within tissue have numerous attractive features for perfusion imaging. Here we present preliminary data illustrating the suitability of hyperpolarized (13)C labeled 2-methylpropan-2-ol (also known as dimethylethanol, tertiary butyl alcohol and tert-butanol) as a freely diffusible contrast agent for magnetic resonance perfusion imaging. Dynamic (13)C images acquired in rat brain with a balanced steady-state free precession sequence following administration of hyperpolarized 2-methylpropan-2-ol show that this agent can be imaged with 2-4 s temporal resolution, 2 mm slice thickness, and 700 μm in-plane resolution while retaining adequate signal-to-noise ratio. (13)C relaxation measurements on 2-methylpropan-2-ol in blood at 9.4 T yield T(1) = 46 ± 4s and T(2) = 0.55 ± 0.03 s. In the rat brain at 4.7 T, analysis of the temporal dynamics of the balanced steady-state free precession image intensity in tissue and venous blood indicate that 2-methylpropan-2-ol has a T(2) of roughly 2-4s and a T(1) of 43 ± 24 s. In addition, the images indicate that 2-methylpropan-2-ol is freely diffusible in brain and hence has a long residence time in tissue; this in turn makes it possible to image the agent continuously for tens of seconds. These characteristics show that 2-methylpropan-2-ol is a promising agent for robust and quantitative perfusion imaging in the brain and body.
    Magnetic Resonance in Medicine 03/2011; 66(3):746-55. · 2.96 Impact Factor
  • Article: Performance evaluation of a 32-element head array with respect to the ultimate intrinsic SNR.
    [show abstract] [hide abstract]
    ABSTRACT: The quality of an RF detector coil design is commonly judged on how it compares with other coil configurations. The aim of this article is to develop a tool for evaluating the absolute performance of RF coil arrays. An algorithm to calculate the ultimate intrinsic signal-to-noise ratio (SNR) was implemented for a spherical geometry. The same imaging tasks modeled in the calculations were reproduced experimentally using a 32-element head array. Coil performance maps were then generated based on the ratio of experimentally measured SNR to the ultimate intrinsic SNR, for different acceleration factors associated with different degrees of parallel imaging. The relative performance in all cases was highest near the center of the samples (where the absolute SNR was lowest). The highest performance was found in the unaccelerated case and a maximum of 85% was observed with a phantom whose electrical properties are consistent with values in the human brain. The performance remained almost constant for 2-fold acceleration, but deteriorated at higher acceleration factors, suggesting that larger arrays are needed for effective highly-accelerated parallel imaging. The method proposed here can serve as a tool for the evaluation of coil designs, as well as a tool to guide the development of original designs which may begin to approach the optimal performance.
    NMR in Biomedicine 11/2009; 23(2):142-51. · 3.21 Impact Factor
  • Article: Electrodynamic constraints on homogeneity and radiofrequency power deposition in multiple coil excitations.
    [show abstract] [hide abstract]
    ABSTRACT: The promise of increased signal-to-noise ratio and spatial/spectral resolution continues to drive MR technology toward higher magnetic field strengths. SAR management and B1 inhomogeneity correction become critical issues at the high frequencies associated with high field MR. In recent years, multiple coil excitation techniques have been recognized as potentially powerful tools for controlling specific absorption rate (SAR) while simultaneously compensating for B1 inhomogeneities. This work explores electrodynamic constraints on transmit homogeneity and SAR, for both fully parallel transmission and its time-independent special case known as radiofrequency shimming. Ultimate intrinsic SAR--the lowest possible SAR consistent with electrodynamics for a particular excitation profile but independent of transmit coil design--is studied for different field strengths, object sizes, and pulse acceleration factors. The approach to the ultimate intrinsic limit with increasing numbers of finite transmit coils is also studied, and the tradeoff between homogeneity and SAR is explored for various excitation strategies. In the case of fully parallel transmission, ultimate intrinsic SAR shows flattening or slight reduction with increasing field strength, in contradiction to the traditionally cited quadratic dependency, but consistent with established electrodynamic principles.
    Magnetic Resonance in Medicine 02/2009; 61(2):315-34. · 2.96 Impact Factor
  • Source
    Article: Comprehensive quantification of signal-to-noise ratio and g-factor for image-based and k-space-based parallel imaging reconstructions.
    [show abstract] [hide abstract]
    ABSTRACT: Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final image. A simple Monte Carlo based method is proposed for all linear image reconstruction algorithms, which allows measurement of signal-to-noise ratio and g-factor and is demonstrated for SENSE and GRAPPA reconstructions for accelerated acquisitions that have not previously been amenable to such assessment. Only a simple "prescan" measurement of noise amplitude and correlation in the phased-array receiver, and a single accelerated image acquisition are required, allowing robust assessment of signal-to-noise ratio and g-factor. The "pseudo multiple replica" method has been rigorously validated in phantoms and in vivo, showing excellent agreement with true multiple replica and analytical methods. This method is universally applicable to the parallel imaging reconstruction techniques used in clinical applications and will allow pixel-by-pixel image noise measurements for all parallel imaging strategies, allowing quantitative comparison between arbitrary k-space trajectories, image reconstruction, or noise conditioning techniques.
    Magnetic Resonance in Medicine 10/2008; 60(4):895-907. · 2.96 Impact Factor
  • Article: Long-lived states in solution NMR: theoretical examples in three- and four-spin systems.
    Aaron K Grant, Elena Vinogradov
    [show abstract] [hide abstract]
    ABSTRACT: Long-lived spin states have been observed in a variety of systems. Although the dynamics underlying the long lifetimes of these states are well understood in the case of two-spin systems, the corresponding dynamics in systems containing more spins appear to be more complex. Recently it has been shown that a selection rule for transitions mediated by intramolecular dipolar relaxation may play a role in determining the lifetimes of long-lived states in systems containing arbitrary numbers of spins. Here we present a theory of long-lived states in systems containing three and four spins and demonstrate how it can be used to identify states that have little or no intramolecular dipolar relaxation.
    Journal of Magnetic Resonance 05/2008; 193(2):177-90. · 2.14 Impact Factor
  • Article: Long-lived states in solution NMR: selection rules for intramolecular dipolar relaxation in low magnetic fields.
    Elena Vinogradov, Aaron K Grant
    [show abstract] [hide abstract]
    ABSTRACT: Recent work has shown that singlet states of two-spin systems in low magnetic fields can have lifetimes up to an order of magnitude longer than the usual spin-lattice relaxation time. This result may enable new applications of NMR, and in particular hyperpolarized NMR via parahydrogen-induced polarization, to the study of slow processes that take place over previously inaccessible timescales. At present it is unclear whether similar results apply to multi-spin systems, or if these long lifetimes are a peculiarity of the two-spin case. Moderately long-lived states have been observed in systems containing more than two spins, although the mechanisms that prolong their lifetimes are not well understood. Here we present formalism for the study of relaxation in multi-spin systems in low magnetic fields. This approach is used to derive a family of quantum-mechanical selection rules governing intramolecular dipolar relaxation at low field that may account for the extended lifetimes observed in multi-spin systems.
    Journal of Magnetic Resonance 10/2007; 188(1):176-82. · 2.14 Impact Factor
  • Article: Toward single breath-hold whole-heart coverage coronary MRA using highly accelerated parallel imaging with a 32-channel MR system.
    [show abstract] [hide abstract]
    ABSTRACT: Coronary MR angiography (CMRA) is generally confined to the acquisition of multiple targeted slabs with coverage dictated by the competing constraints of signal-to-noise ratio (SNR), physiological motion, and scan time. This work addresses these obstacles by demonstrating the technical feasibility of using a 32-channel coil array and receiver system for highly accelerated volumetric breath-hold CMRA. The use of the 32-element array in unaccelerated CMRA studies provided a baseline SNR increase of as much as 40% over conventional cardiac-optimized phased array coils, which resulted in substantially enhanced image quality and improved delineation of the coronary arteries. Modest accelerations were used to reduce breath-hold durations for tailored coverage of the coronary arteries using targeted multi-oblique slabs to as little as 10 s. Finally, high net accelerations were combined with the SNR advantages of a 3D steady-state free precession (SSFP) technique to achieve previously unattainable comprehensive volumetric coverage of the coronary arteries in a single breath-hold. The merits and limitations of this simplified volumetric imaging approach are discussed and its implications for coronary MRA are considered.
    Magnetic Resonance in Medicine 08/2006; 56(1):167-76. · 2.96 Impact Factor
  • Article: 32-element receiver-coil array for cardiac imaging.
    [show abstract] [hide abstract]
    ABSTRACT: A lightweight 32-element MRI receiver-coil array was designed and built for cardiac imaging. It comprises an anterior array of 21 copper rings (75 mm diameter) and a posterior array of 11 rings (107 mm diameter) that are arranged in hexagonal lattices so as to decouple nearest neighbors, and curved around the left side of the torso. Imaging experiments on phantoms and human volunteers show that it yields superior performance relative to an eight-element cardiac array as well as a 32-element whole-torso array for both traditional nonaccelerated cardiac imaging and 3D parallel imaging with acceleration factors as high as 16.
    Magnetic Resonance in Medicine 06/2006; 55(5):1142-9. · 2.96 Impact Factor
  • Article: Phase-constrained parallel MR image reconstruction.
    [show abstract] [hide abstract]
    ABSTRACT: A generalized method for phase-constrained parallel MR image reconstruction is presented that combines and extends the concepts of partial-Fourier reconstruction and parallel imaging. It provides a framework for reconstructing images employing either or both techniques and for comparing image quality achieved by varying k-space sampling schemes. The method can be used as a parallel image reconstruction with a partial-Fourier reconstruction built in. It can also be used with trajectories not readily handled by straightforward combinations of partial-Fourier and SENSE-like parallel reconstructions, including variable-density, and non-Cartesian trajectories. The phase constraint specifies a better-conditioned inverse problem compared to unconstrained parallel MR reconstruction alone. This phase-constrained parallel MRI reconstruction offers a one-step alternative to the standard combination of homodyne and SENSE reconstructions with the added benefit of flexibility of sampling trajectory. The theory of the phase-constrained approach is outlined, and its calibration requirements and limitations are discussed. Simulations, phantom experiments, and in vivo experiments are presented.
    Journal of Magnetic Resonance 11/2005; 176(2):187-98. · 2.14 Impact Factor
  • Article: Inherently self-calibrating non-Cartesian parallel imaging.
    [show abstract] [hide abstract]
    ABSTRACT: The use of self-calibrating techniques in parallel magnetic resonance imaging eliminates the need for coil sensitivity calibration scans and avoids potential mismatches between calibration scans and subsequent accelerated acquisitions (e.g., as a result of patient motion). Most examples of self-calibrating Cartesian parallel imaging techniques have required the use of modified k-space trajectories that are densely sampled at the center and more sparsely sampled in the periphery. However, spiral and radial trajectories offer inherent self-calibrating characteristics because of their densely sampled center. At no additional cost in acquisition time and with no modification in scanning protocols, in vivo coil sensitivity maps may be extracted from the densely sampled central region of k-space. This work demonstrates the feasibility of self-calibrated spiral and radial parallel imaging using a previously described iterative non-Cartesian sensitivity encoding algorithm.
    Magnetic Resonance in Medicine 08/2005; 54(1):1-8. · 2.96 Impact Factor
  • Article: Rapid volumetric MRI using parallel imaging with order-of-magnitude accelerations and a 32-element RF coil array: feasibility and implications.
    [show abstract] [hide abstract]
    ABSTRACT: Many clinical applications of Magnetic Resonance Imaging are constrained by basic limits on imaging speed. Parallel MRI relaxes these limits by using the sensitivity patterns of arrays of radiofrequency receiver coils to encode spatial information in a manner complementary to traditional encoding with magnetic field gradients. Until now, parallel MRI has been used to achieve modest improvements in imaging speed; order-of-magnitude improvements have been elusive given fundamental losses in signal-to-noise ratio. The goal of this work was to demonstrate that, with appropriate hardware and careful SNR management, rapid volumetric imaging at high accelerations is in fact feasible. Contrast-enhanced MRI with an axial 3D spoiled gradient echo imaging sequence was performed in healthy adult subjects using a 32-element RF coil array and a prototype 32-channel MR imaging system. Large imaging volumes were prescribed, in place of traditional limited slabs targeted only to suspect regions. As much as 16-fold net accelerations of imaging were achieved repeatably using this approach. The use of large 3D volumes allowed comprehensive anatomical coverage at clinically useful spatial and/or temporal resolution. The need for careful, time-consuming, and subject-specific scan prescription was also eliminated. The highly parallel imaging approach presented here allows previously inaccessible volumetric coverage for time-sensitive MRI examinations such as contrast-enhanced MRA, and simultaneously provides a substantially simplified imaging paradigm. The resulting capability for rapid volumetric imaging promises to combine the strengths of MRI with some of the advantages of alternative imaging modalities such as multidetector CT.
    Academic Radiology 06/2005; 12(5):626-35. · 1.69 Impact Factor
  • Article: Ultimate intrinsic signal-to-noise ratio for parallel MRI: electromagnetic field considerations.
    [show abstract] [hide abstract]
    ABSTRACT: A method is described for establishing an upper bound on the spatial encoding capabilities of coil arrays in parallel MRI. Ultimate intrinsic signal-to-noise ratio (SNR), independent of any particular conductor arrangement, is calculated by expressing arbitrary coil sensitivities in terms of a complete set of basis functions that satisfy Maxwell's equations within the sample and performing parallel imaging reconstructions using these basis functions. The dependence of the ultimate intrinsic SNR on a variety of experimental conditions is explored and a physically intuitive explanation for the observed behavior is provided based on a comparison between the electromagnetic wavelength and the distance between aliasing points. Imaging at high field strength, with correspondingly short wavelength, is shown to offer advantages for parallel imaging beyond those already expected due to the larger available spin polarization. One-dimensional undersampling of k-space yields a steep drop in attainable SNR for more than a 5-fold reduction of scan time, while 2D undersampling permits access to much higher degrees of acceleration. Increased tissue conductivity decreases baseline SNR, but improves parallel imaging performance. A procedure is also provided for generating the optimal coil sensitivity pattern for a given acceleration, which will serve as a useful guide for future coil designs.
    Magnetic Resonance in Medicine 12/2003; 50(5):1018-30. · 2.96 Impact Factor
  • Article: Hyperpolarized long-lived states in solution NMR: Three-spin case study in low field
    Elena Vinogradov, Aaron K. Grant
    [show abstract] [hide abstract]
    ABSTRACT: Recent work has shown that singlet states in two-spin systems can possess lifetimes exceeding the T1 relaxation time, provided that the system is kept under conditions that minimize the effects of the chemical shift Hamiltonian (for instance under low magnetic field or RF irradiation). Similar observations have been made in hyperpolarized states of multi-spin systems prepared via parahydrogen-induced polarization (PHIP). However, lifetime prolongation mechanisms in multi-spin systems are still under investigation. Here we present experimental observations of a long-lived state in a three-spin system prepared by PHIP and stored at low field. The observed lifetime of the long-lived state is 144s, about twice as long as the longest T1 measured in the system at high field. The results are analyzed using a recently proposed theory of lifetime prolongation in multi-spin systems in low field. It is shown that quantum mechanical selection rules governing intramolecular dipolar relaxation in low field account for the enhanced lifetime and spectral features of this state.
    Journal of Magnetic Resonance.

Institutions

  • 2007–2011
    • Beth Israel Deaconess Medical Center
      • Department of Radiology
      Boston, MA, USA
  • 2009
    • NYU Langone Medical Center
      • Department of Radiology
      New York City, NY, USA
  • 2006
    • General Electric Company
      Fairfield, CA, USA
    • Rheinisch-Westfälische Technische Hochschule Aachen
      Aachen, North Rhine-Westphalia, Germany
  • 2005
    • University of California, Davis
      Davis, CA, USA
  • 2003
    • Massachusetts Institute of Technology
      Cambridge, MA, USA