Publications (6)25.55 Total impact
-
Article: AV nodal reentrant tachycardia causing inappropriate ICD shocks in a patient with arrhythmogenic RV dysplasia.
[show abstract] [hide abstract]
ABSTRACT: We report a patient with an implantable cardioverter defibrillator (ICD) for arrhythmogenic right ventricular dysplasia (ARVD) who received inappropriate shocks for atrioventricular node reentry tachycardia (AVRNT). Patient had multiple shocks for tachycardia with EGM characteristics of very short VA interval and CL of 300 msec. An electrophysiologic (EP) study reproducibly induced typical AVNRT with similar features. The slow AV nodal pathway ablation resolved the ICD shocks. Despite increasingly sophisticated discrimination algorithms available in modern ICDs, the ability to differentiate SVT from VT can be challenging. Our patient received inappropriate shocks for AVNRT. When device interrogation alone is not conclusive, an EP study may be necessary to determine the appropriate therapeutic course.Indian pacing and electrophysiology journal 02/2009; 9(1):60-3. -
Article: Impact of a comprehensive safety program on radiation exposure during catheter ablation of atrial fibrillation: a prospective study.
[show abstract] [hide abstract]
ABSTRACT: Pulmonary vein antral isolation (PVAI) is an effective treatment for atrial fibrillation and involves prolonged procedure and fluoroscopy times. This study assesses the impact of a comprehensive radiation safety program on patient and operator radiation exposure during PVAI. We evaluated a comprehensive radiation safety program including: (1) verbal reinforcement of previous fluoroscopy times (2) effective collimation (3) minimizing source-intensifier distance and (4) effective lead shield use. Exposure doses in 41 consecutive patients without (group-I, n = 21) and with (group-II, n = 20) the use of radiation safety program were assessed. PVAI was done using intracardiac echo (ICE) guided roving circular mapping catheter. A 3-dimensional mapping system was used in 27% cases for additional guidance. Operator and patient exposure was measured during the PVAI. The age, gender, body mass index and AF duration were similar in both of the groups. The total procedure (166 +/- 56 vs 178 +/- 38 min, p = 0.54) and fluoroscopy times (74 +/- 24 vs 70 +/- 20 min, p = 0.72) were comparable. Group-II had significantly lower dose area product (234 +/- 120 vs 548 +/- 363 Gy cm(2), p = 0.03) compared to group-I. The mean operator exposure was reduced by half and mean patient peak skin dose by three to ten times with comprehensive radiation safety program. None of the patients were noted to have radiation related skin injuries. Additional lifetime cancer risk was significantly lower in group-II patients (0.08 vs 0.2%, p < 0.001) than group-I. Implementation of a comprehensive radiation safety program described above significantly decreases the radiation exposure to the patient as well as the operator.Journal of Interventional Cardiac Electrophysiology 12/2008; 24(2):105-12. · 1.17 Impact Factor -
Article: Intracardiac echo-guided radiofrequency catheter ablation of atrial fibrillation in patients with atrial septal defect or patent foramen ovale repair: a feasibility, safety, and efficacy study.
[show abstract] [hide abstract]
ABSTRACT: Intracardiac Echo-Guided Radiofrequency Catheter. Patients with atrial septal defect (ASD) are at higher risk for atrial fibrillation (AF) even after repair. Transseptal access in these patients is perceived to be difficult. We describe the feasibility, safety, and efficacy of pulmonary vein antral isolation (PVAI) in these patients. We prospectively compared post-ASD/patent foramen ovale (PFO) repair patients (group I, n = 45) with age-gender-AF type matched controls (group II, n = 45). All the patients underwent PVAI through a double transseptal puncture with a roving circular mapping catheter technique guided by intracardiac echocardiography (ICE). The short-term (3 months) and long-term (12 month) failure rates were assessed. In group I, 23 (51%) had percutaneous closure devices and 22 (49%) had a surgical closure. There was no significant difference between group I and II in the baseline characteristics. Intracardiac echo-guided double transseptal access was obtained in 98% of patients in group I and in 100% of patients in group II. PVAI was performed in all patients, with right atrial flutter ablation in 7 patients in group I and in 4 patients in group II. Over a mean follow-up of 15 +/- 4 months, group I had higher short-term (18% vs 13%, P = 0.77) and long-term recurrence (24% vs 18%, P = 0.6) than group II. There was no significant difference in the perioperative complications between the two groups. Echocardiography at 3 months showed interatrial communication in 2 patients in group I and 1 patient in group II, which resolved at 12 months. Percutaneous AF ablation using double transseptal access is feasible, safe, and efficacious in patients with ASD and PFO repairs.Journal of Cardiovascular Electrophysiology 08/2008; 19(11):1137-42. · 3.06 Impact Factor -
Article: Pulmonary vein total occlusion following catheter ablation for atrial fibrillation: clinical implications after long-term follow-up.
[show abstract] [hide abstract]
ABSTRACT: We present the clinical course and management outcomes of patients with total pulmonary vein occlusion (PVO). Pulmonary vein occlusion is a rare complication that can develop after radiofrequency catheter ablation (RFA) of atrial fibrillation (AF). The long term follow-up data of patients diagnosed with PVO are minimal. Data from 18 patients with complete occlusion of at least one pulmonary vein (PV) were prospectively collected. All patients underwent RFA for AF using different strategies between September 1999 and May 2004. Pulmonary vein occlusion was diagnosed using computed tomography (CT) and later confirmed by angiography when intervention was warranted. Lung perfusion scans were performed on all patients before and after intervention. The percent stenoses of the veins draining each independent lung were added together to yield an average cumulative stenosis of the vascular cross-sectional area draining the affected lung (cumulative stenosis index [CSI]). The patients' symptoms had a positive correlation with the CSI (r = 0.843, p < 0.05) and a negative one with the lung perfusion (r = -0.667, p < 0.05). A CSI > or =75% correlated well with low lung perfusion (<25%; r = -0.854, p < 0.01). Patients with a CSI > or =75% appeared to improve mostly when early (r = -0.497) and repeat dilation/stenting (r = 0.0765) were performed. Patients with single PVO are mostly asymptomatic and should undergo routine imaging. On the other hand, patients with concomitant ipsilateral PV stenosis/PVO and a CSI > or =75% require early and, when necessary, repeated pulmonary interventions for restoration of pulmonary flow and prevention of associated lung disease.Journal of the American College of Cardiology 12/2006; 48(12):2493-9. · 14.16 Impact Factor -
Article: Phrenic nerve injury after catheter ablation: should we worry about this complication?
[show abstract] [hide abstract]
ABSTRACT: Phrenic nerve injury (PNI) is a complication that can occur with catheter ablation. Data from 17 patients with PNI following different catheter ablation techniques were reviewed. PNI was defined as decreased motility (transient) or paralysis (persistent) of the hemi-diaphragm on fluoroscopy or chest X-ray. Patient's recovery was monitored. Normalization of chest images and sniff test would be considered as complete clinical recovery. Out of the 17 PNI patients (16 right, 1 left), 13 (11 persistent, 2 transient) occurred after pulmonary veins isolation with or without superior vena cava ablation. Three patients had persistent PNI after sinus node modification and one other patient experienced PNI after epicardial ventricular tachycardia ablation. Ablation was performed with different energy source including radiofrequency (n = 13), cryothermal (n = 1), ultrasound (n = 2) and laser (n = 1). Patient's symptoms varied broadly from asymptomatic to dyspnea, and even to respiratory insufficiency that required temporary mechanical ventilation support. Two patients with transient PNI resolved immediately after the procedure and the other 15 persistent PNI patients resolved within a mean time of 8.3 +/- 6.6 months. PNI caused by catheter ablation appears to functionally recover over time regardless of the energy sources used for the procedure.Journal of Cardiovascular Electrophysiology 10/2006; 17(9):944-8. · 3.06 Impact Factor -
Article: Safety and efficacy of radiofrequency energy catheter ablation of atrial fibrillation in patients with pacemakers and implantable cardiac defibrillators.
[show abstract] [hide abstract]
ABSTRACT: Catheter ablation has significantly transformed the clinical management of atrial fibrillation (AF). The safety and efficacy of this procedure are not well understood in patients with pacemakers and defibrillators. The purpose of this study was to study the impact of radiofrequency catheter ablation of AF in patients with pacemakers and implantable cardiac defibrillators. We studied 86 patients with pacemakers and defibrillators (group I) and a similar number of age- and gender-matched controls (group II) who underwent AF ablation between 1999 and 2004. Clinical and procedural variables were compared between the two groups. In group I, various generator and lead parameters were compared before and after the procedure. Resurgence of clinical AF after 2 months was considered recurrence. Both groups were similar with regard to age, gender, body mass index, and type of AF. Group I had a higher incidence of diabetes (17% vs 6%, P = .03), coronary artery disease (25% vs 13%, P = .05), less prolonged AF (31 +/- 21 vs 45 +/- 30 months, P <.001), lower left ventricular ejection fraction (49 +/- 13% vs 52 +/- 9%, P = .03), and left ventricular end-diastolic dimensions (4.97 +/- 0.81 vs 4.72 +/- 0.67, P = .03). No changes in the sensing and pacing thresholds, impedance of atrial and ventricular leads, or defibrillator coil impedance after AF ablation were observed in group I. Atrial lead dislodgment was seen in two patients. Transient abnormal but "expected" pulse generator behavior was seen in 25% of patients without permanent malfunction. Stroke (1% vs 1%, P = 1.000), pulmonary vein stenosis (2% vs 1%, P = .77), and AF recurrence rates at 12 months were similar between groups I and II, respectively (19% vs 21%, P = .73). AF ablation is safe and efficacious in patients with pacemakers and defibrillators.Heart Rhythm 01/2006; 2(12):1309-16. · 4.10 Impact Factor