  • Article: Mid-infrared fiber-coupled photoacoustic sensor for biomedical applications.
    [show abstract] [hide abstract]
    ABSTRACT: Biomedical devices employed in therapy, diagnostics and for self-monitoring often require a high degree of flexibility and compactness. Many near infrared (NIR) optical fiber-coupled systems meet these requirements and are employed on a daily basis. However, mid-infrared (MIR) fibers-based systems have not yet found their way to routine application in medicine. In this work we present the implementation of the first MIR fiber-coupled photoacoustic sensor for the investigation of condensed samples in the MIR fingerprint region. The light of an external-cavity quantum-cascade laser (1010-1095 cm-1) is delivered by a silver halide fiber, which is attached to the PA cell. The PA chamber is conically shaped to perfectly match the beam escaping the fiber and to minimize the cell volume. This results in a compact and handy sensor for investigations of biological samples and the monitoring of constituents both in vitro and in vivo. The performance of the fiber-coupled PA sensor is demonstrated by sensing glucose in aqueous solutions. These measurements yield a detection limit of 57 mg/dL (SNR = 1). Furthermore, the fiber-coupled sensor has been applied to record human skin spectra at different body sites to illustrate its flexibility.
    Sensors 01/2013; 13(1):535-49. · 1.74 Impact Factor
  • Source
    Article: Glucose sensing in human epidermis using mid-infrared photoacoustic detection.
    [show abstract] [hide abstract]
    ABSTRACT: No reliable non-invasive glucose monitoring devices are currently available. We implemented a mid-infrared (MIR) photoacoustic (PA) setup to track glucose in vitro in deep epidermal layers, which represents a significant step towards non-invasive in vivo glucose measurements using MIR light. An external-cavity quantum-cascade laser (1010-1095 cm(-1)) and a PA cell of only 78 mm(3) volume were employed to monitor glucose in epidermal skin. Skin samples are characterized by a high water content. Such samples investigated with an open-ended PA cell lead to varying conditions in the PA chamber (i.e., change of light absorption or relative humidity) and cause unstable signals. To circumvent variations in relative humidity and possible water condensation, the PA chamber was constantly ventilated by a 10 sccm N(2) flow. By bringing the epidermal skin samples in contact with aqueous glucose solutions with different concentrations (i.e., 0.1-10 g/dl), the glucose concentration in the skin sample was varied through passive diffusion. The achieved detection limit for glucose in epidermal skin is 100 mg/dl (SNR=1). Although this lies within the human physiological range (30-500 mg/dl) further improvements are necessary to non-invasively monitor glucose levels of diabetes patients. Furthermore spectra of epidermal tissue with and without glucose content have been recorded with the tunable quantum-cascade laser, indicating that epidermal constituents do not impair glucose detection.
    Biomedical Optics Express 04/2012; 3(4):667-80. · 2.33 Impact Factor
  • Source
    Article: Vapor-phase infrared laser spectroscopy: from gas sensing to forensic urinalysis.
    [show abstract] [hide abstract]
    ABSTRACT: Numerous gas-sensing devices are based on infrared laser spectroscopy. In this paper, the technique is further developed and, for the first time, applied to forensic urinalysis. For this purpose, a difference frequency generation laser was coupled to an in-house-built, high-temperature multipass cell (HTMC). The continuous tuning range of the laser was extended to 329 cm(-1) in the fingerprint C-H stretching region between 3 and 4 microm. The HTMC is a long-path absorption cell designed to withstand organic samples in the vapor phase (Bartlome, R.; Baer, M.; Sigrist, M. W. Rev. Sci. Instrum. 2007, 78, 013110). Quantitative measurements were taken on pure ephedrine and pseudoephedrine vapors. Despite featuring similarities, the vapor-phase infrared spectra of these diastereoisomers are clearly distinguishable with respect to a vibrational band centered at 2970.5 and 2980.1 cm(-1), respectively. Ephedrine-positive and pseudoephedrine-positive urine samples were prepared by means of liquid-liquid extraction and directly evaporated in the HTMC without any preliminary chromatographic separation. When 10 or 20 mL of ephedrine-positive human urine is prepared, the detection limit of ephedrine, prohibited in sports as of 10 microg/mL, is 50 or 25 microg/mL, respectively. The laser spectrometer has room for much improvement; its potential is discussed with respect to doping agents detection.
    Analytical Chemistry 08/2008; 80(14):5334-41. · 5.86 Impact Factor
  • Article: Laser fibre deterioration and loss of power output during photo-selective 80-w potassium-titanyl-phosphate laser vaporisation of the prostate.
    [show abstract] [hide abstract]
    ABSTRACT: The potassium-titanyl-phosphate (KTP) laser technique for photo-selective vaporisation of the prostate (PVP) has been regularly improved over the last decade. Nonetheless, decreasing efficiency of tissue vaporisation during the course of the operation and macroscopic alterations of the laser fibre's tip are regularly observed and seem to affect the outcome of this procedure. To investigate the course of power output and to determine the type and extent of fibre deterioration during PVP. Forty laser fibres were investigated during PVP in 35 consecutive patients with prostatic bladder outflow obstruction between January 2007 and August 2007 in a university hospital. All patients underwent PVP performed by three different surgeons using the 80-W KTP laser. Power output was measured at the beginning and regularly throughout PVP and throughout in vitro vaporisation without fibre-tissue contact. Microscopic documentation of the fibre tip was performed after the procedure. Carbonisation and melting of the fibre tip was regularly visible and appeared to be more pronounced as more energy was applied. Additionally, 90% of the fibres showed a significant decrease of power output during PVP, resulting in an end-of-lifespan (ie, 275-kilojoule) median power output of 20% of the initial value. Final median power output after in vitro vaporisation was 83% of the starting value. The extent of the structural and functional changes might only be valid for the operative technique performed in this investigation. Fibre deterioration caused significant reduction of power output during PVP. This finding is an explanation for the often observed decreasing efficiency of tissue ablation and may also be responsible for some of the typical drawbacks and complications of PVP. Hence, improvements in fibre quality are necessary to advance the efficiency of this technique.
    European urology 04/2008; 55(3):679-85. · 7.67 Impact Factor
  • Article: Spectroscopic investigation of methylated amines by a cavity-ringdown-based spectrometer.
    [show abstract] [hide abstract]
    ABSTRACT: High-resolution absorption spectra of gas-phase monomethylamine (MMA, CH(3)NH(2)) and dimethylamine [DMA, (CH(3))(2)NH] in the region of the first overtone of the NH stretch vibration are reported. Measurements were performed with a near-infrared laser spectrometer based on the cavity-ringdown (CRD) detection technique. The minimum detectable absorption coefficient for the CRD detection setup is alpha(min)=1.55 x 10(-8) cm(-1) (for SNR = 1). This corresponds to detection limits of 350 parts in 10(9) (ppb) for MMA and 1.6 parts in 10(6) (ppm) for DMA in synthetic gas mixtures under interference-free conditions, or 10 ppm and 60 ppm for MMA and DMA, respectively, in the case of gas mixtures such as exhaled human breath containing H(2)O, CO(2), and other absorbing gases in this range.
    Applied Optics 08/2007; 46(19):3981-6. · 1.41 Impact Factor
  • Article: New differential mode excitation photoacoustic scheme for near-infrared water vapour sensing
    Julien M. Rey, Markus W. Sigrist
    [show abstract] [hide abstract]
    ABSTRACT: A new gas sensor based on the differential mode excitation photoacoustic (DME-PA) technique is presented. The DME-PA method utilizes the selective excitation of two different modes in a resonant photoacoustic cell and the gas concentration is derived from the amplitude ratio of these acoustic modes. The presented device has only one cell that acts as both sample and photoacoustic cell and uses a current-modulated near-infrared light emitting diode as excitation source. No power-meter is required for PA signal normalization. The new DME-PA sensor was tested with water vapour yielding a ±250 ppm uncertainty for the water vapour content of ambient air.
    Sensors and Actuators B: Chemical.
  • Article: Bending loss measurement using a fiber cavity ringdown scheme
    [show abstract] [hide abstract]
    ABSTRACT: A novel sensitive technique for the determination of losses in fiber cavities is presented. The method is based on the cavity ringdown scheme implemented in silica-based single-mode fibers. Bending losses of fiber cavities of different lengths have been measured showing all an oscillating behavior with respect to the curvature radius of the fiber as predicted by a theoretical model. The best minimum detectable absorbance per cavity pass achieved by this new method is 1.72×10−3 dB within a 10 m-long cavity. This limit suffices well for an accurate determination of optical bending losses even in bend-insensitive fibers. Furthermore, the comparison of the measured bending losses with a theoretical model allows the extraction of different fiber parameters. Good agreement has been found between the experimentally derived parameters and literature data.
    Optics and Lasers in Engineering.