-
[show abstract]
[hide abstract]
ABSTRACT: Specific parameters of the neuronal tissue microstructure, such as axonal diameters, membrane permeability and intracellular water fractions are assessable using diffusion MRI. These parameters are commonly estimated using analytical models, which may introduce bias in the estimated parameters due to the approximations made when deriving the models. As an alternative to using analytical models, a database of signal curves generated by fast Monte Carlo simulations can be employed. Simulated diffusion MRI measurements were generated and evaluated using the two-compartment Kärger model as well as the simulation model based on a database containing signal curves from approximately 60000 simulations performed with different combinations of microstructural parameters. A protocol based on a pulsed gradient spin echo sequence with diffusion times of 30 and 60 ms and with gradient amplitudes obtainable with a clinical MRI scanner was employed for the investigations. When using the analytical model, a major negative bias (up to approximately 25%) in the estimated intracellular volume fraction was observed for short exchange times, while almost no bias was seen for the simulation model. In general, the simulation model improved the accuracy of the estimated parameters as compared to the analytical model, except for the exchange time parameter.
Journal of Magnetic Resonance 09/2010; 206(1):59-67. · 2.14 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: Cerebral perfusion parameters were measured using dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) in eight healthy volunteers examined during normal breathing and spontaneous hyperventilation. DSC-MRI-based cerebral blood flow (CBF) decreased during hyperventilation in all volunteers (average decrease 29%), and the corresponding global CBF estimates were 73 plusmn 19 ml/(min 100 g) during normal breathing and 52 plusmn 7.9 ml/(min 100 g) during hyperventilation (mean plusmn SD, n = 8). Furthermore, the hypocapnic conditions induced by hyperventilation resulted in a prolongation of the mean transit time (MTT) by on average 13%. The observed CBF estimates appeared to be systematically overestimated, in accordance with previously published DSC-MRI results, but reduced to more reasonable levels when a previously retrieved calibration factor was applied.
Bioinformatics and Biomedical Engineering , 2009. ICBBE 2009. 3rd International Conference on; 07/2009
-
[show abstract]
[hide abstract]
ABSTRACT: The aim of this study was to investigate the diffusion time dependence of signal-versus-b curves obtained from diffusion-weighted magnetic resonance imaging (DW-MRI) of sub-acute ischaemic lesions in stroke patients. In this case series study, 16 patients with sub-acute ischaemic stroke were examined with DW-MRI using two different diffusion times (60 and 260 ms). Nine of these patients showed sufficiently large lesions without artefacts to merit further analysis. The signal-versus-b curves from the lesions were plotted and analysed using a two-compartment model including compartmental exchange. To validate the model and to aid the interpretation of the estimated model parameters, Monte Carlo simulations were performed. In eight cases, the plotted signal-versus-b curves, obtained from the lesions, showed a signal-curve split-up when data for the two diffusion times were compared, revealing effects of compartmental water exchange. For one of the patients, parametric maps were generated based on the extracted model parameters. These novel observations suggest that water exchange between different water pools is measurable and thus potentially useful for clinical assessment. The information can improve the understanding of the relationship between the DW-MRI signal intensity and the microstructural properties of the lesions.
NMR in Biomedicine 04/2009; 22(6):619-28. · 3.21 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: Attempts to retrieve absolute values of cerebral blood flow (CBF) by dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) have typically resulted in overestimations.
To improve DSC-MRI CBF estimates by calibrating the DSC-MRI-based cerebral blood volume (CBV) with a corresponding T1-weighted (T1W) steady-state (ss) CBV estimate.
17 volunteers were investigated by DSC-MRI and 133Xe SPECT. Steady-state CBV calculation, assuming no water exchange, was accomplished using signal values from blood and tissue, before and after contrast agent, obtained by T1W spin-echo imaging. Using steady-state and DSC-MRI CBV estimates, a calibration factor K = CBV(ss)/CBV(DSC) was obtained for each individual. Average whole-brain CBF(DSC) was calculated, and the corrected MRI-based CBF estimate was given by CBF(ss) = K x CBF(DSC).
Average whole-brain SPECT CBF was 40.1+/-6.9 ml/min x 100 g, while the corresponding uncorrected DSC-MRI-based value was 69.2+/-13.8 ml/min x 100 g. After correction with the calibration factor, a CBF(ss) of 42.7+/-14.0 ml/min x 100 g was obtained. The linear fit to CBF(ss)-versus-CBF(SPECT) data was close to proportionality (R = 0.52).
Calibration by steady-state CBV reduced the population average CBF to a reasonable level, and a modest linear correlation with the reference 133Xe SPECT technique was observed. Possible explanations for the limited accuracy are, for example, large-vessel partial-volume effects, low post-contrast signal enhancement in T1W images, and water-exchange effects.
Acta Radiologica 07/2007; 48(5):550-6. · 1.37 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: To examine the influence of different doses of gadolinium contrast agent on synovial enhancement, to compare magnetic resonance imaging (MRI) findings of synovial hypertrophy and radiographic joint changes in hemophiliacs, and to investigate the value of gadolinium in MRI assessment of synovial hypertrophy in hemophiliacs using dynamic MRI and MRI scoring.
Twenty-one hemophiliacs on prophylactic factor treatment without recent bleeds were subjected to radiography and gadolinium contrast-enhanced dynamic and static MRI of the knee using a standard dose of 0.1 mmol/kg b.w. gadoteridol. In 17 of the patients, the MRI procedure was repeated after a triple dose of gadoteridol.
MRI findings of synovial hypertrophy were significantly correlated with Pettersson radiographic scores. In 19 of the 21 MRI investigated joints, administration of contrast agent did not alter the result of the evaluation of synovial hypertrophy.
The optimal time interval for volume assessment of synovial hypertrophy after injection of gadolinium contrast agent is dose dependent. Hemophiliacs without recent bleeds have minor to abundant synovial hypertrophy in joints with pronounced radiographic changes. Dynamic MRI is not useful for evaluating hemophilic arthropathy, and gadolinium contrast agent is not routinely indicated for MRI scoring of joints in hemophiliacs.
Acta Radiologica 07/2007; 48(5):520-30. · 1.37 Impact Factor
-
IEEE Trans. Med. Imaging. 01/2007; 26:1437-1447.
-
[show abstract]
[hide abstract]
ABSTRACT: To assess the value of the combined use of dynamic susceptibility contrast-enhanced perfusion magnetic resonance imaging (MRI) and conventional contrast-enhanced MRI for the follow-up of treatment of glioblastoma multiforme (GBM).
79 examinations were performed in six surgically and immunogene-treated patients and two surgically treated patients. Ratios of the relative cerebral blood volume (rCBV) in lesions and in the contralateral normal-appearing white matter were calculated. The regions with elevated rCBV were compared with those with contrast enhancement. Tissue specimens from surgical biopsies and autopsies were studied histopathologically.
The lesion-to-normal rCBV ratios were high in the tumors prior to operation (7.3 to 18.2) as well as in the recurrent tumors (1.6 to 13.2). The volumes of the regions with elevated rCBV were similar to those with contrast enhancement in 63 of the 79 examinations. However, in 11 of 79 examinations, the regions with high rCBV were smaller than the regions with contrast enhancement ("mismatch"). In two samples from the immunogene-treated patients this was correlated with the histopathological finding of malignant tumor with numerous proliferating GBM vessels with multiple minimal lumina, sometimes thrombotized or ruptured. These vessels may have increased permeability with contrast enhancement not accompanied by increased microvascular volume.
1) Elevated rCBV on perfusion MRI corresponding to the contrast-enhancing lesion supports the diagnosis of recurrent malignant tumor. 2) A mismatch showing a volume of rCBV elevation smaller than that of contrast enhancement can be seen in particularly aggressive tumor growth and is thus not always a sign of reactive non-tumor changes. 3) The combination of perfusion MRI and conventional contrast MRI provides useful information in the follow-up of glioblastoma multiforme treatment.
Acta Radiologica 11/2006; 47(8):852-61. · 1.37 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: Endovascular embolization is an increasingly common method to treat intracerebral arteriovenous malformations (AVM). To date, however, published data are rather scarce, especially with regard to true procedure-related complications and their causes. The purpose of our study was to evaluate treatment safety and correlate anatomic results with clinical outcome by using MR imaging, including diffusion-weighted (DWI) and perfusion imaging (PI).
We performed 50 endovascular procedures in 21 patients. Most AVMs were supratentorial, Spetzler-Martin grades II-IV. MR imaging was scheduled within 1 week before and 3 days after each treatment. MR imaging findings were correlated to digital subtraction angiography, procedure reports, and the clinical course. Outcome was graded according to the modified Rankin scale (mRS) 3-6 months after treatment.
In this study, 104 MR imaging examinations were performed; mean interval between the endovascular procedure and posttreatment MR imaging was 28 hours. Nine adverse events occurred in 7 patients during 8 procedures (16%), one causing a permanent deficit. New lesions were noted on MR imaging after 22/50 procedures. Ischemic lesions in 22% of the procedures, frequently located perinidally. Most lesions were small, frequently asymptomatic, and reversible (18/23). Four hematomas were found. Subacute hemorrhages developed from a vasogenic edema on 2 occasions. New lesions, including hematomas, developed between treatments in 4 patients, mainly because of progressive occlusion of the nidus or draining veins. PI overestimated the AVM nidus on most occasions, and transient worsening of the PI pattern was noted in 2 patients. Treatment-related mortality and morbidity were 0% and 14.2%, respectively (mRS 1-2).
Endovascular procedures are rather safe but are associated with more ischemic events and followed by less hemodynamic disturbances than previously understood. Adverse procedural events and new MR imaging lesions were generally asymptomatic and most often transient, if symptomatic. Most lesions would not have been verified without MR imaging. DWI and PI were most useful to detect and understand the cause of various complications. The most clinically important complications were caused by late venous occlusions.
American Journal of Neuroradiology 02/2006; 27(1):162-76. · 2.93 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: Our purpose was to evaluate treatment safety as well as complications frequency and management in endovascular coiling of intracerebral aneurysms using MR diffusion and perfusion imaging. In this prospective study, 77 MR examinations were performed in conjunction with 43 procedures in 40 patients, 14 patients presented with ruptured and 26 with unruptured aneurysms. Mean time interval between treatment and post-procedure MRI was 29 and 25 h for the ruptured and unruptured aneurysm group, respectively. Peri-procedural complications, including five major events and five minor transient events, occurred in 10/43 procedures (23%), necessitating thrombolytic therapy in two patients and angioplasty in one, all three within the unruptured aneurysm group. Fifty-one new lesions were found on post-treatment DWI and 47 of them were regarded as of ischemic origin. Most lesions were small (<3 mm), ipsilateral to the treated aneurysm and asymptomatic (37/40 patients). Sixty-seven percent of the lesions were found in the ruptured and 33% in the unruptured aneurysm group. The ischemic lesions did occur more frequently in patients treated for aneurysm of large neck size and according to the remodelling technique. The overall morbidity and mortality rates were 14.6 and 7.3% whereas morbidity and mortality rates related to the technique were only 2.6 and 0%, respectively. Silent embolism seems to be more common than clinically evident and partially related to patient presentation, heparinazation and treatment strategy. The capability to depict early complications and analyse their potential causes by using MR with DWI has been of great importance in our modification and improvement of therapeutic protocols, evaluations and strategies.
Neuroradiology 11/2005; 47(11):855-73. · 2.82 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: Dynamic susceptibility-contrast (DSC) MRI requires deconvolution to retrieve the tissue residue function R(t) and the cerebral blood flow (CBF). In this study, deconvolution of time-series data was performed by wavelet-transform-based denoising combined with the Fourier transform (FT). Traditional FT-based deconvolution of noisy data requires frequency-domain filtering, often leading to excessive smoothing of the recovered signal. In the present approach, only a low degree of regularisation was employed while the major noise reduction was accomplished by wavelet transformation of data and Wiener-like filtering in the wavelet space. After inverse wavelet transform, the estimate of CBF.R(t) was obtained. DSC-MRI signal-versus-time curves (signal-to-noise ratios 40 and 100) were simulated, corresponding to CBF values in the range 10-60 ml/(min 100 g). Three shapes of the tissue residue function were investigated. The technique was also applied to six volunteers. Simulations showed CBF estimates with acceptable accuracy and precision, as well as independence of any time shift between the arterial input function and the tissue concentration curve. The grey-matter to white-matter CBF ratio in volunteers was 2.4+/-0.2. The proposed wavelet/FT deconvolution is robust and can be implemented into existing perfusion software. CBF maps from healthy volunteers showed high quality.
MAGMA Magnetic Resonance Materials in Physics Biology and Medicine 08/2005; 18(3):113-8. · 1.88 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: A new technique for assessing tissue blood flow using hyperpolarized tracers, based on the fact that the magnetization of a hyperpolarized substance can be destroyed permanently, is described. Assessments of blood flow with this technique are inherently insensitive to arterial delay and dispersion, and allow for quantification of the transit time and dispersion in the arteries that supply the investigated tissue. Renal cortical blood flow was studied in six rabbits using a 13C-labeled compound (2-hydroxyethylacrylate) that was polarized by the parahydrogen-induced polarization (PHIP) technique. The renal cortical blood flow was estimated to be 5.7/5.4 +/- 1.6/1.3 ml/min per milliliter of tissue (mean +/- SD, right/left kidney), and the mean transit time and dispersion in the renal arteries were determined to be 1.47/1.42 +/- 0.07/0.07 s and 1.78/1.93 +/- 0.40/0.42 s2, respectively.
Magnetic Resonance in Medicine 12/2004; 52(5):1043-51. · 2.96 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: A new technique for assessing tissue blood flow using hyperpolarized tracers, based on the fact that the magnetization of a hyperpolarized substance can be destroyed permanently, is described. Assessments of blood flow with this technique are inherently insensitive to arterial delay and dispersion, and allow for quantification of the transit time and dispersion in the arteries that supply the investigated tissue. Renal cortical blood flow was studied in six rabbits using a 13C-labeled compound (2-hydroxyethylacrylate) that was polarized by the parahydrogen-induced polarization (PHIP) technique. The renal cortical blood flow was estimated to be 5.7/5.4 ± 1.6/1.3 ml/min per milliliter of tissue (mean ± SD, right/left kidney), and the mean transit time and dispersion in the renal arteries were determined to be 1.47/1.42 ± 0.07/0.07 s and 1.78/1.93 ± 0.40/0.42 s2, respectively. Magn Reson Med 52:1043–1051, 2004. © 2004 Wiley-Liss, Inc.
Magnetic Resonance in Medicine 10/2004; 52(5):1043 - 1051. · 2.96 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: The implications of changing the echo time of a gradient-echo echo planar imaging sequence applied to dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) for perfusion imaging at 3T were investigated. Four echo times in the range of 21 to 45 ms were examined in a total of 17 patients who received a dose of 0.1 mmol/kg bodyweight Gadobutrol (Gadovist, 1.0 mmol/ml). As the primary optimization parameter, the concentration-to-noise ratio (SNRc) was selected as it takes effects of variations in baseline as well as in signal drop into account. In an analysis of gray matter, white matter and arterial regions of interest, SNRc showed the highest values for the shortest applied echo time in all cases. Maps of regional cerebral blood volume (rCBV) and blood flow (rCBF) were calculated using deconvolution based on singular value decomposition. The quality of rCBF and rCBV images was judged to be good or excellent in all cases, independent of the echo time. Calculated gray matter/white matter ratios of rCBF and rCBV displayed no significant dependence on the applied echo time. Considering the better SNRc and arterial signal saturation aspects, we found that the shortest investigated echo time was the superior one. We thus suggest that short echo times should be applied, taking technical limitations and clinical demands into consideration.
Magnetic Resonance Imaging 10/2004; 22(7):929-35. · 1.99 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: Cerebral perfusion was assessed with 13C MRI in a rat model after intravenous injections of the 13C-labeled compound bis-1,1-(hydroxymethyl)-1-13C-cyclopropane-D8 in aqueous solutions hyperpolarized by dynamic nuclear polarization (DNP). Since the tracer acted as a direct signal source, several of the problems associated with techniques based on traditional dynamic susceptibility contrast (DSC) MRI contrast agents were avoided. Maps of cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) were calculated. The MTT was determined to be 2.8 +/- 0.8 sec. However, arterial partial-volume effects in the animal model prevented accurate absolute quantification of CBF and CBV. It was demonstrated that depolarization of the hyperpolarized 13C tracer via relaxation and the imaging sequence had little influence on CBF assessment when the time resolution of the imaging sequence was short compared to the MTT. However, CBV and MTT were increasingly underestimated as MTT or the depolarization rate increased if depolarization was not taken into account. With a modified bolus-tracking theory depolarization could be compensated for, assuming that the depolarization rate was known. Three separate compensation methods were investigated experimentally and by numerical simulations.
Magnetic Resonance in Medicine 04/2004; 51(3):464-72. · 2.96 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: We describe three patients in whom we used MRI, including diffusion- and perfusion-weighted imaging (DWI, PWI) in conjunction with endovascular therapy. Two had intracranial aneurysms and one an arteriovenous malformation (AVM). The aneurysms were treated by coil embolisation or detachable balloons for proximal artery occlusion; the AVM was obliterated by intranidal glue injection. All patients had transient or permanent neurological deficits after treatment. The MRI techniques and interventional procedures are described and the DWI and PWI patterns found are correlated with the clinical features. We discuss how the information gained from MRI may increase our understanding of procedure-related complications and its potential impact on our therapeutic interventions, in order to prevent or limit the clinical consequences of such events.
Neuroradiology 09/2001; 43(8):662-71. · 2.82 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: Perfusion-related parameters obtained by intravoxel incoherent motion (IVIM) MR imaging (MRI) were compared with cerebral blood volume and flow (CBV and CBF), retrieved by dynamic susceptibility-contrast (DSC) MRI.
Twenty-eight volunteers (average age 68.5 years) were investigated. Spin-echo echo-planar imaging with IVIM-encoding gradients was employed (36 different b values, 0-1200 s/mm2). The perfusion fraction and the pseudo-diffusion coefficient were calculated for regions in thalamus gray matter and frontal white matter, using asymptotic and full fitting. In DSC-MRI, a Gd-DTPA-BMA contrast-agent bolus was monitored using simultaneous-dual FLASH. Deconvolution of the measured tissue concentration-versus-time curve with an arterial input function from the carotid artery was applied, and maps of CBV and CBF were calculated.
The correlation between the perfusion fraction and CBV was r=0.56 (p<0.0000006) using asymptotic fitting, and r=0.35 (p<0.0004) when full fitting was applied. Average CBF was 41.5 ml/(min 100 g), to be compared with the IVIM-based value of 63.6 ml/(min 100 g), obtained from the median value of the pseudo-diffusion coefficient in combination with assumptions about capillary network structure.
The IVIM concept provided results that agreed reasonably with conventional CBV and CBF. The non-linear fitting to noisy signal data was problematic, in accordance with previously presented simulations.
Acta Radiologica 03/2001; 42(2):123-8. · 1.37 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: Absolute regional cerebral blood flow (CBF) was measured in ten healthy volunteers, using both dynamic susceptibility-contrast (DSC) magnetic resonance imaging (MRI) and Xe-133 SPECT within 4 h. After i.v. injection of Gd-DTPA-BMA (0.3 mmol/kg b.w.), the bolus was monitored with a Simultaneous Dual FLASH pulse sequence (1.5 s/image), providing one slice through brain tissue and a second slice through the carotid artery. Concentration C(t) is proportional to -(1/TE) ln[S(t)/S(0)] was related to CBF as C(t) = CBF [AIF(t) x R(t)], where AIF is the arterial input function and R(t) is the residue function. A singular-value-decomposition-based deconvolution technique was used for retrieval of R(t). Absolute CBF was given by Zierler's area-to-height relation and the central volume principle. For elimination of large vessels (ELV), all MRI-based CBF values exceeding 2.5 times the mean CBF value of the slice were excluded. A correction for partial-volume effects (CPVE) in the artery used for AIF monitoring was based on registration of signal in a phantom with tubes of various diameters (1.5-6.5 mm), providing an individual concentration correction factor applied to AIF data registered in vivo. In the Xe-133 SPECT investigation, 3,000-4,000 MBq of Xe-133 was administered intravenously, and CBF was calculated using the Kanno Lassen algorithm. When ELV and CPVE were applied, DSC-MRI showed average CBF values from the entire slice of 43 +/- 10 ml/(min 100 g) (small-artery AIF) and 48 +/- 17 ml/(min 100 g) (carotid-artery AIF) (mean +/- S.D., n = 10). The corresponding Xe-133-SPECT-based CBF was 33 +/- 6 ml/(min 100 g) (n = 10). The relationships of CBF(MRI) versus CBF(SPECT) showed good linear correlation (r = 0.74-0.83).
MAGMA Magnetic Resonance Materials in Physics Biology and Medicine 01/2001; 11(3):96-103. · 1.88 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: Regional cerebral blood flow (rCBF) was assessed using dynamic susceptibility-contrast MRI at 1.5 T. A simultaneous dual FLASH pulse sequence and Gd-DTPA-BMA (0.3 mmol/kg b.w.) were used for examination of 43 volunteers, measuring rCBF in frontal white matter (WM) and in gray matter in the thalamus (GM). Arterial input functions (AIFs) were registered 1) in the carotid artery and 2) in an artery within the GM/WM slice. The measured concentration-vs. -time curve was deconvolved with the AIF using both Fourier Transform (FT) and Singular Value Decomposition (SVD). Relative rCBF was given by the height of the deconvolved response curve. For each volunteer, eight different rCBF maps were calculated, representing different combinations of deconvolution techniques, AIFs, and filters. The average GM-WM rCBF ratios ranged from 2.0-2.2, depending on methodology. Absolute rCBF was 68 +/- 28 ml/(min 100 g) in GM and 35 +/- 13 ml/(min 100g) in WM (mean +/- SD, n = 39). GM-WM rCBF ratios obtained using SVD were 6-10% higher than corresponding ratios obtained using FT.
Magnetic Resonance in Medicine 06/2000; 43(5):691-700. · 2.96 Impact Factor
-
Acta Radiologica 06/1999; 40(3):339. · 1.37 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: The aim of this study was to evaluate any possible effects of brain motion, CSF pulsations and other possible sources of physiological motion in electrocardiographic (ECG) triggered and non-triggered single-shot echo-planar imaging (EPI) measurements of diffusion.
Three different triggering protocols were evaluated in 6 healthy volunteers: 1) ECG triggering with time delay (TD) 100 ms; 2) ECG triggering with TD 400 ms; and 3) no triggering at all.
The results obtained showed that white matter mean apparent diffusion coefficient (ADC) values were similar for all triggering protocols and that the reproducibility in ADC measurements using diffusion-weighted (DW) EPI was good. The average standard deviation of the ADC values was, however, higher for ADC maps obtained without ECG triggering.
The use of prospective diastolic ECG triggering significantly improves the accuracy of quantitative diffusion measurements but for routine clinical diffusion imaging, where quantitative data is of less importance, the accuracy obtained without ECG triggering can be considered adequate.
Acta Radiologica 06/1999; 40(3):263-9. · 1.37 Impact Factor