A Pasquarelli

Department of Physics, Pontificia Universidade Católica, Rio de Janeiro, Brazil.

Publications of A Pasquarelli

  • Open magnetic and electric graphic analysis

    Authors: H.-P. Muller, I. Decesaris, M. Demelis, L. Marzetti, A. Pasquarelli, S.N. Erne, A.C. Ludolph, J. Kassubek

    Engineering in Medicine and Biology Magazine, IEEE. 06/2005;

    In this article, a novel analysis technique, open magnetic and electric graphic analysis (OMEGA), is described and is applied to combine MEG and fMRI measurements in a motor task. The study was
  • Argos 500: operation of a helmet vector-MEG.

    Authors: A Pasquarelli, R. Rossi, M De Melis, L Marzetti, A. Trebeschi, H P Müller, S N Erné

    Neurology & clinical neurophysiology : NCN. 02/2004; 2004:97.

    We here describe the MEG system recently installed at the University of Ulm; it is specifically designed for clinical application and routine use, to allow investigation of a large number of patients
  • Multi-channel magnetocardiography for detecting beat morphology variations in fetal arrhythmias.

    Authors: R Sturm, H P Müller, A Pasquarelli, M DeMelis, S N Erné, R Terinde, D Lang

    Prenatal diagnosis. 02/2004; 24(1):1-9.

    OBJECTIVE: Over the last few years, a number of studies have shown that fetal magnetocardiography (fMCG) is useful in describing fetal cardiac activity. A 55-channel MCG system in Ulm was used to
  • Calibration of a vector-MEG helmet system.

    Authors: A Pasquarelli, M De Melis, L Marzetti, H P Müller, S N Erné

    Neurology & clinical neurophysiology : NCN. 02/2004; 2004:94.

    The MEG system Argos 500, recently installed at the University of Ulm, is designed for clinical application and routine use, to allow investigation of a large number of patients per day. To reach
  • MSR upgrade for clinical MEG

    Authors: A Pasquarelli, S. N. Ern, A. Trebeschi

    12/2001;

    Introduction To accommodate the new Argos 500 MEG instrument [1] a general upgrade of the existing 2+1layer magnetically shielded room at the neurological department was necessary. Due to the
  • A 165-Channel Neuromagnetometer for Multimodal Brain Imaging

    Authors: V Pizzella, S Della Penna, S. N. Ern, C. Granata, A Pasquarelli, K Torquati, R. Rossi, M. Russo

    12/2001;

    this paper we report about a 165-channel neuromagnetic system developed in an frame of an international multidisciplinary cooperation between the Advanced Biomedical Technologies (ITAB) of the
  • The study of steady magnetic fields associated with primary and secondary ST shift in ischaemic rabbit hearts.

    Authors: E C Monteiro, S Della Penna, L. Di Donato, S Di Luzio, A Pasquarelli, S N Erné, G L Romani

    Physiological measurement. 09/1997; 18(3):191-200.

    The study of injury potentials associated with DC currents that generate the primary or secondary ST shifts during cardiac ischaemia is possible only through the invasive technique of the DC
  • A SQUID based AC susceptometer for the investigation of large samples.

    Authors: A Pasquarelli, C Del Gratta, S Della Penna, S Di Luzio, V Pizzella, G L Romani

    Physics in medicine and biology. 12/1996; 41(11):2533-9.

    We developed a SQUID based susceptometer with a large available magnetized volume for the investigation of large objects. The magnetizing field is generated by a pair of Helmoltz coils. To achieve a
  • Topography and sources of electromagnetic cerebral responses to electrical and air-puff stimulation of the hand.

    Authors: P M Rossini, G Deuschl, V Pizzella, F Tecchio, A Pasquarelli, E Feifel, G L Romani, C H Lücking

    Electroencephalography and clinical neurophysiology. 06/1996; 100(3):229-39.

    SEPs and SEFs after air-puff stimulation of index and little fingers have been studied and compared to the responses following electrical stimulation of the same digits and of the median nerve at the
  • Analysis of interhemispheric asymmetries of somatosensory evoked magnetic fields to right and left median nerve stimulation.

    Authors: P M Rossini, L Narici, G Martino, A Pasquarelli, M Peresson, V Pizzella, F Tecchio, G L Romani

    Electroencephalography and clinical neurophysiology. 01/1995; 91(6):476-82.

    This paper represents the first neuromagnetic systematic investigation of the asymmetries between the sources activated in the right and left hemispheres after electric median nerve stimulation. We
  • Magnetocardiography and exercise testing.

    Authors: K Brockmeier, S Comani, S N Erné, S Di Luzio, A Pasquarelli, G L Romani

    Journal of electrocardiology. 05/1994; 27(2):137-42.

    Twenty healthy male subjects (age range, 15-25 years; median, 21 years) underwent magnetocardiography during physical exercise. Significant ST-segment displacements of the magnetic signal were found
  • Short-term brain 'plasticity' in humans: transient finger representation changes in sensory cortex somatotopy following ischemic anesthesia.

    Authors: P M Rossini, G Martino, L Narici, A Pasquarelli, M Peresson, V Pizzella, F Tecchio, G. Torrioli, G L Romani

    Brain research. 05/1994; 642(1-2):169-77.

    Transient rearrangements of finger representation in primary somatosensory cortex induced by an anesthetic block of the sensory information from adjacent fingers have been shown invasively in
  • 11 channel magnetometer for biomagnetic measurements in unshielded environments

    Authors: S. Casciardi, C. Del Gratta, S. Di Luzio, G.L. Romani, V. Foglietti, A. Pasquarelli, V. Pizzella, G. Torrioli

    Applied Superconductivity, IEEE Transactions on. 04/1993;

    The authors describe a novel 11-channel magnetometer designed for operation in unshielded environments. The planar geometry of the system is particularly suitable for recording biomagnetic signals
  • Operation of a hybrid 28-channel neuromagnetometer

    Authors: V. Foglietti, A. Pasquarelli, V. Pizzella, G. Torrioli, G.L. Romani, S. Casciardi, W.J. Gallagher, M.B. Ketchen, A.W. Kleinsasser, R.L. Sandstrom

    Applied Superconductivity, IEEE Transactions on. 04/1993;

    A 28-channel system for neuromagnetic measurements operative at CNR-IESS (Instituto di Elettronica dello Stato Solido) is described. The instrument uses 28 Nb/PbAuIn DC-SQUID (superconducting
  • Measurement of segmental transit through the gut in man. A novel approach by the biomagnetic method.

    Authors: M Basile, M Neri, A Carriero, S Casciardi, S Comani, C Del Gratta, L. Di Donato, S Di Luzio, M A Macri, A Pasquarelli

    Digestive diseases and sciences. 10/1992; 37(10):1537-43.

    The techniques commonly used to evaluate the transit of contents through the gut feature some limitations for being either inaccurate, invasive, inconvenient, or potentially dangerous for the
  • Magnetocardiography and exercise testing: data acquisition and data processing

    Authors: K. Brockmeier, S. Comani, S.N. Erne, C. De Gratta, S. Di Luzio, A. Pasquarelli, G.L. Romani

    Computers in Cardiology 1991, Proceedings.; 10/1991

    Sixteen healthy male subjects underwent magnetocardiography during physical exercise. A specific signal averaging technique was developed because the quality of the magnetic signals exceeded that of
  • 28-channel hybrid system for neuromagnetic measurements

    Authors: V. Foglietti, C. Del Gratta, A. Pasquarelli, V. Pizzella, G. Torrioli, G.L. Romani, W.J. Gallagher, M.B. Ketchen, A.W. Kleinsasser, R.L. Sandstrom

    Magnetics, IEEE Transactions on. 04/1991;

    Progress toward the development of a 28-multichannel system for neuromagnetic measurements is described. A novel hybrid design consisting of 16 first-order axial gradiometers and 12
  • Multichannel hybrid system for neuromagnetic measurements.

    Authors: V. Foglietti, C Del Gratta, A Pasquarelli, V Pizzella, G. Torrioli, G L Romani, W.J. Gallagher, M.B. Ketchen, A.W. Kleinsasser, R.L. Sandstrom

    Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft für Medizinische Physik and the European Federation of Organisations for Medical Physics. 02/1991; 12 Suppl B:31-7.

    This paper describes progress toward the development of a 28-multichannel system for neuromagnetic measurements. A novel 'hybrid' design consisting of 16 first-order axial gradiometers and 12
  • Measurement of gastrointestinal transit time by means of biomagnetic instrumentation: preliminary results.

    Authors: M A Macri, M Basile, A Carriero, S Casciardi, S Comani, C Del Gratta, L. Di Donato, S Di Luzio, M Neri, A Pasquarelli

    Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft für Medizinische Physik and the European Federation of Organisations for Medical Physics. 02/1991; 12 Suppl A:111-5.

    The measurement of gastrointestinal transit time, GITT, is of particular interest in the study of gastrointestinal activity and in the diagnosis of some pathologies. In the present work we report the
  • Analysis of the ST-segment in terms of principal components: application on multichannel magnetocardiographic recordings.

    Authors: B G Schless, H P Müller, M DeMelis, A Pasquarelli, S N Erné, V Hombach

    Journal of medical engineering & technology. 28(2):56-60.

    Parameterization of the ST-segment is used as a tool for risk stratification for patients to suffer from ventricular tachycardia. This parameterization is performed in terms of Principal Component

Are you A Pasquarelli?

Claim your profile

Keywords of A Pasquarelli

Advanced Biomedical Technologies
 
cardiac activity
 
complete ischemic anesthesia
 
fetal cardiac activity
 
first-order planar gradiometers
 
healthy human volunteers
 
negative feedback control
 
planar gradiometers
 
segment changes
 
transit time
 
17.14
Impact Points
27
Publications

Institutions

  • 1997
    • Pontifícia Universidade Católica do Rio de Janeiro (PUC-Rio)
      Rio de Janeiro, Rio de Janeiro, Brazil
  • 1996
    • CNR - Consiglio Nazionale delle Ricerche
      Roma, Latium, Italy
  • 1991–1994
    • Freie Universität Berlin
      Berlin, Land Berlin, Germany
  • 1991–1992
    • Università degli Studi G. d'Annunzio Chieti e Pescara
      Chieti, Abruzzo, Italy