ABSTRACT: In this paper, we present preliminary results showing the response of glucose-sensitive hydrogels, confined in micro-pressure sensors, to the changes in environmental glucose concentration. The glucose concentrations were incrementally varied between 20 and 0mM in 0.15M PBS solution at 7.4 pH and bovine serum at 7.4 pH at room temperature and response of the sensor was recorded. The micro sensors demonstrate a response time of 10 minutes in both PBS and serum. Tissue response after 55 days of subcutaneous implantation of a EtO sterilized sensor in mice is presented. The preliminary analysis of the surrounding tissue shows inflammation which is believed not to interfere with the sensor performance.
Engineering in Medicine and Biology Society (EMBC), 2010 Annual International Conference of the IEEE; 10/2010
-
[show abstract]
[hide abstract]
ABSTRACT: Perfluoropentane (PFP), a very hydrophobic, nontoxic, noncarcinogenic fluoroalkane, has generated much interest in biomedical applications, including occlusion therapy and controlled drug delivery. For most of these applications, the dispersion within aqueous media of a large quantity of PFP droplets of the proper size is critically important. Surprisingly, the interfacial tension of PFP against water in the presence of surfactants used to stabilize the emulsion has rarely, if ever, been measured. In this study, we report the interfacial tension of PFP in the presence of surfactants used in previous studies to produce emulsions for biomedical applications: polyethylene oxide-co-polylactic acid (PEO-PLA) and polyethylene oxide-co-poly-epsilon-caprolactone (PEO-PCL). Because both of these surfactants are uncharged diblock copolymers that rely on the mechanism of steric stabilization, we also investigate for comparison's sake the use of the small-molecule cationic surfactant cetyl trimethyl ammonium bromide (CTAB) and the much larger protein surfactant bovine serum albumin (BSA). The results presented here complement previous reports of the PFP droplet size distribution and will be useful for determining to what extent the interfacial tension value can be used to control the mean PFP droplet size.
Langmuir 03/2010; 26(7):4655-60. · 4.19 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: In this paper, we present preliminary results showing the response of glucose-sensitive hydrogels, confined in micro-pressure sensors, to the changes in environmental glucose concentration. The glucose concentrations were incrementally varied between 20 and 0mM in 0.15M PBS solution at 7.4 pH and bovine serum at 7.4 pH at room temperature and response of the sensor was recorded. The micro sensors demonstrate a response time of 10 minutes in both PBS and serum. Tissue response after 55 days of subcutaneous implantation of a EtO sterilized sensor in mice is presented. The preliminary analysis of the surrounding tissue shows inflammation which is believed not to interfere with the sensor performance.
Conference proceedings: ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference 01/2010; 2010:677-9.
-
[show abstract]
[hide abstract]
ABSTRACT: A “smart” hydrogel is a crosslinked polymer network that reversibly swells and absorbs water in response to an external stimulus such as change in pH or in the concentration of some analyte such as glucose. Microscopically-thin smart hydrogels can be combined with microfabricated piezoresistive pressure transducers to obtain “chemomechanical sensors” that serve as selective and versatile wireless biomedical sensors. Proof-of-concept is shown here using glucose- and pH-responsive hydrogels.
MRS Proceedings. 12/2008; 1234.