Are you Valdir Ambrósio Moises?

Claim your profile

Publications (2)2.63 Total impact

  • Article: Biological factors and overestimation of left ventricular ejection fraction by gated SPECT.
    [show abstract] [hide abstract]
    ABSTRACT: Some patients present an overestimated left ventricular ejection fraction (LVEF) on electrocardiogram-gated myocardial scintigraphy (gated SPECT). To establish the relationship between biological factors and overestimated LVEF. We selected 3838 patients who underwent gated SPECT between May 20, 2000 and September 16, 2005 with normal perfusion images and LVEF > or =50%. The following variables were analyzed: gender (29.4% females and 70.6% males), age (from 20 to 94 years - mean: 56 years), weight (from 33.5 to 150 kg - mean: 79.6 kg), height (from 138 to 220 cm - mean: 171 cm) and BMI (from 13.9 to 54 - mean: 27.2). In a subgroup of 1002 patients who underwent echocardiogram, the diastolic diameter (from 36 to 68 mm - mean 47.5 mm) and systolic diameter (from 22 to 41 mm - mean 29.8 mm) variables were included. The patients were divided into two groups: normal LVEF (< or =80%) and overestimated LVEF (>80%). The odds ratio (OR) for presenting an overestimated LVEF was calculated for each variable using logistic regression. The following odds ratios were found (p < 0.005): female gender OR = 3.585 (95%CI: 2.745 to 4.683), age in years OR = 1.020 (95%CI: 1.011 to 1.029) and height in cm OR = 0.893 (95%CI: 0.829 to 0.962). Weight and BMI were not significantly associated with LVEF (p>0.2). In the subgroup of 1002 patients, a statistically significant influence was found in overestimated LVEF values for the systolic diameter, gender and height variables. Although systolic diameter influences the overestimation of LVEF, the gender and height variables have an independent influence on LVEF overestimation by gated SPECT.
    Arquivos brasileiros de cardiologia 05/2008; 90(5):305-10. · 1.32 Impact Factor
  • Article: Echocardiograph pulmonary venous flow patterns in congenital heart defects with increased pulmonary flow.
    [show abstract] [hide abstract]
    ABSTRACT: To describe pulmonary venous flow patterns using transthoracic echocardiograms on children suffering from different congenital heart defects with increased pulmonary flow. Prospective study and consecutive selection of children suffering from congenital heart defects with increased pulmonary flow. The transthoracic, apical view, Doppler echocardiogram was used, positioning the sample-volume at the lower pulmonary vein, 4mm from its junction with the left atrium. The data analyzed included: dominant systolic or diastolic pulmonary venous flow and atrial contraction waveform characteristics, designated as "A" for absent and "R" for reversed. The study included twenty-nine patients with a mean age of 29.9 +/- 58.9 months, suffering from the following congenital heart conditions: interatrial and interventricular communication defects, patent ductus arteriosus, atrioventricular septal defects, total transposition of the great arteries and truncus arteriosus. All the patients presented a continuous pattern of high velocity pulmonary venous flow. Nine patients presented a dominant systolic waveform (31%), eighteen presented a dominant diastolic wave form (62%) and 2 patients had systolic and diastolic wave forms of equal amplitude (7%). Six patients (21%) presented a R atrial contraction waveform and 23 (79%) presented an A atrial contraction waveform. Congenital heart diseases with increased pulmonary flow present a continuous pattern of high velocity pulmonary venous flow with alterations mainly in the atrial contraction reversal pattern.
    Arquivos brasileiros de cardiologia 05/2007; 88(4):396-401. · 1.32 Impact Factor