Tang Jing-Tian

Central South University, Changsha, Hunan, China

Are you Tang Jing-Tian?

Claim your profile

Publications (3)0 Total impact

  • Source
    Conference Proceeding: Medical Images Edge Detection Based on Mathematical Morphology
    [show abstract] [hide abstract]
    ABSTRACT: Medical images edge detection is an important work for object recognition of the human organs and it is an important pre-processing step in medical image segmentation and 3D reconstruction. Conventionally, edge is detected according to some early brought forward algorithms such as gradient-based algorithm and template-based algorithm, but they are not so good for noise medical image edge detection. In this paper, basic mathematical morphological theory and operations are introduced at first, and then a novel mathematical morphological edge detection algorithm is proposed to detect the edge of lungs CT image with salt-and-pepper noise. The experimental results show that the proposed algorithm is more efficient for medical image denoising and edge detection than the usually used template-based edge detection algorithms and general morphological edge detection algorithms
    Engineering in Medicine and Biology Society, 2005. IEEE-EMBS 2005. 27th Annual International Conference of the; 02/2006
  • Source
    Article: Medical images edge detection based on mathematical morphology.
    [show abstract] [hide abstract]
    ABSTRACT: Medical images edge detection is an important work for object recognition of the human organs and it is an important pre-processing step in medical image segmentation and 3D reconstruction. Conventionally, edge is detected according to some early brought forward algorithms such as gradient-based algorithm and template-based algorithm, but they are not so good for noise medical image edge detection. In this paper, basic mathematical morphological theory and operations are introduced at first, and then a novel mathematical morphological edge detection algorithm is proposed to detect the edge of lungs CT image with salt-and-pepper noise. The experimental results show that the proposed algorithm is more efficient for medical image denoising and edge detection than the usually used template-based edge detection algorithms and general morphological edge detection algorithms.
    Conference proceedings: ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference 02/2005; 6:6492-5.
  • Article: Development of a Portable Blood Sugar Apparatus and GOD Enzyme Strip.
    [show abstract] [hide abstract]
    ABSTRACT: A pocket blood sugar apparatus tested by enzyme electrode, which was designed using carbon and silver plasma as conducting materials. Both the work and reference electrodes are applied to the parts of enzyme electrode. The glucose oxidase is taken as the medium of blood sugar measuring. And the range of measuring glucose is about 50mg/dL - 500mgl/dL. It has better linear for the results and fit coefficient arrives at 0.985. Its sensitivity of measurement is higher than current glucose biosensor obviously. A single chip microcomputer, AD mu C812, is used for central control processor of the instrument parts. It measures the output of microampere level currency, which is conduced by blood sugar reacting with the glucose oxidase on the enzyme electrode. And at the same time, the microampere level currency is amplified, processed. Then the results are displayed on LCD. The apparatus are better for measuring blood sugar, and the results are consistent with what the large biochemical instruments get.
    Conference proceedings: ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference 02/2005; 1:248-51.