ABSTRACT: High-temperature thermal therapy is emerging as a feasible treatment option for prostate cancer and benign prostatic hyperplasia. Previous investigations have demonstrated distinct advantages of catheter-based ultrasound technology over other heating modalities for thermal ablation therapies, with significant potential for better spatial control and faster heating times. The purpose of this study was to develop ultrasound devices and techniques specifically for treating prostate cancer in conjunction with magnetic resonance thermal imaging (MRTI) to monitor and control treatment progression. Directional transurethral applicators have been designed with arrays of sectored tubular (90 degrees active acoustic sector) or with narrow planar transducer segments and integrated with a flexible delivery catheter with a cooling balloon. This applicator can be rotated within the prostatic urethra to target specific regions during treatment. MRI compatible catheter-cooled interstitial ultrasound applicators with 180 degrees active acoustic sectors were developed specifically to treat the prostate. These applicators may be implanted through the perineum into the posterior portion of the prostate, with their heating energy directed away from the rectum. Both heating strategies were evaluated via biothermal simulations and in vivo experiments within canine prostate (n = 3). During the in vivo studies, MRTI was used to monitor treatment temperatures, cytotoxic thermal doses (t43 > 240 min) and corresponding maximum temperature thresholds (Tmax > 52 degrees C) within three imaging planes simultaneously. Urethral and endorectal cooling was employed with both treatment strategies to provide further protection of the urethral mucosa and rectum from thermal damage. Results using the transurethral applicators demonstrated that narrow zones of coagulation (approximately 30 degrees sector for planar, approximately 90 degrees for tubular), extending up to 20 mm from the urethra to the periphery of the prostate gland, could be produced within 10-15 min. Further, rotation of the applicator during treatment could be used to destroy larger regions in the prostate. Experiments using multiple interstitial directional applicators (approximately 180 degrees active sectors), implanted within the posterior margin of the prostate with the energy directed away from the rectum, produced contiguous zones of thermal coagulation which extended from the posterior prostate toward the anterior-lateral periphery of the gland. Both transurethral and interstitial treatment strategies demonstrated significant potential for thermal ablation of localized prostate cancer, particularly when MRTI is used to guide and assess treatment.
International Journal of Hyperthermia 12/2004; 20(7):739-56. · 1.92 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: High-temperature thermal therapy for the treatment of prostate cancer is currently being applied as a minimally-invasive alternative over traditional forms of treatment. Catheter-based interstitial and transurethral ultrasound applicators are being developed for controlled and selective thermal ablation of prostaric tissues with concurrent MR thermal imaging. As part of this treatment strategy we have devised a transurethral cooling catheter and a cooling jacket to be placed over the endorectal MR imaging coil to protect the urethral mucosa and rectal wall from thermal damage during treatment. The cooling efficiencies and protective abilities of these devices were evaluated in vivo within three canine prostate glands. Invasive and MR derived temperature measurements within the prostate and rectal wall indicate that the protective influence of the endorectal cooling extends 5-10 mm from the rectal wall into the dorsal prostate. The urethral cooling extends ∼5 mm from the cooling balloon. The protective capabilities were further verified with subsequent histological analysis with TTC stained tissue sections and contrast enhanced T1-weighted MR images post treatment. Both of these cooling devices are compatible with the MR thermometry and can be used to protect the urethral mucosa and rectal wall during prostate thermal ablation with interstitial and transurethral ultrasound devices.
Engineering in Medicine and Biology Society, 2004. IEMBS '04. 26th Annual International Conference of the IEEE; 10/2004
-
[show abstract]
[hide abstract]
ABSTRACT: Thermal ablation has been investigated as a treatment for a variety of cancers. Heat treatments have not gained large-scale clinical acceptance due to inconsistencies in controlling heat deposition in vivo and the lack of precise temperature measurement. Interstitial ultrasound provide a good method of controlling the radial depth of a thermal lesion and the applicator designs evaluated in this study allow for dynamic angular control of the shape of the lesion. A trisectored internally water-cooled applicator (TriAD) and a rotating catheter water-cooled applicator (RIUS) angularly controlled thermal dose to a target area. Both devices were small in diameter (1.8 mm-2.4 mm), making them clinically feasible for minimally invasive treatment in device size-sensitive tissues. A biothermal model accounting for changes in acoustic attenuation and perfusion as a function of thermal dose was used to evaluate and predict applicator performance. The MR susceptibility artifact of the applicators was examined with MR temperature imaging (MRTI) sequences at 1.5 T and 0.5 T. Ex vivo experiments in turkey and beef muscle with realtime MRTI correlated well with results from the biothermal model. These results display the feasibility of thermally treating tumors with controllable interstitial ultrasound applicators under real-time MRTI and bracket the applicators' predicted performance in vivo.
Engineering in Medicine and Biology Society, 2004. IEMBS '04. 26th Annual International Conference of the IEEE; 10/2004
-
[show abstract]
[hide abstract]
ABSTRACT: Referenceless proton resonance frequency (PRF) shift thermometry provides a means to measure temperature changes during minimally invasive thermotherapy that is inherently robust to motion and tissue displacement. In this study, the method is expanded to allow background phase estimation from fatty tissue. A correction scheme for temperature map distortions caused by the ultrasound applicator is developed. The method is tested during thermal ablation of canine prostate using a directional transurethral ultrasound applicator.
Engineering in Medicine and Biology Society, 2004. IEMBS '04. 26th Annual International Conference of the IEEE; 10/2004
-
[show abstract]
[hide abstract]
ABSTRACT: High-temperature thermal therapy for the treatment of prostate cancer is currently being applied as a minimally-invasive alternative over traditional forms of treatment. Catheter-based interstitial and transurethral ultrasound applicators are being developed for controlled and selective thermal ablation of prostaric tissues with concurrent MR thermal imaging. As part of this treatment strategy we have devised a transurethral cooling catheter and a cooling jacket to be placed over the endorectal MR imaging coil to protect the urethral mucosa and rectal wall from thermal damage during treatment. The cooling efficiencies and protective abilities of these devices were evaluated in vivo within three canine prostate glands. Invasive and MR derived temperature measurements within the prostate and rectal wall indicate that the protective influence of the endorectal cooling extends 5-10 mm from the rectal wall into the dorsal prostate. The urethral cooling extends approximately 5 mm from the cooling balloon. The protective capabilities were further verified with subsequent histological analysis with TTC stained tissue sections and contrast enhanced T1-weighted MR images post treatment. Both of these cooling devices are compatible with the MR thermometry and can be used to protect the urethral mucosa and rectal wall during prostate thermal ablation with interstitial and transurethral ultrasound devices.
Conference proceedings: ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference 02/2004; 4:2492-5.