[show abstract]
[hide abstract]
ABSTRACT: A novel two dimensional surface plasmon resonance (SPR) sensor system with a multi-point sensing region is described. The use of multiplied beam splitting optics, as a core technology, permitted multi-point sensing to be achieved. This system was capable of simultaneously measuring nine sensing points. Calibration curves for sucrose obtained on nine sensing points were linear in the range of 0-10% with a correlation factor of 0.996-0.998 with a relative standard deviation of 0.090-4.0%. The detection limits defined as S/N = 3 were 1.98 × 10-6-3.91 × 10-5 RIU. This sensitivity is comparable to that of conventional SPR sensors.
Sensors 01/2013; 13(1):801-12. · 1.74 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: The performance of an organic thin film photodiode (OPD), fabricated from a hetero-junction comprised of two layers of C(60) and a phthalocyanine-Cu(II) complex was evaluated by detecting the chemiluminescence generated from the reaction of luminol with horseradish peroxidase in the presence of H(2)O(2), and the fluorescence from resorufin, as an optical detector. The photocurrent of the OPD was linear with respect to the power of light from a commercial LED. The sensitivity of the OPD was sufficient for detecting chemiluminescence with a power 0.1μW/cm(2). The OPD was successfully used in a flow-immunoassay for IgA, a marker of human stress, in which a sandwich immunoassay was carried out on the microchip and the fluorescence from resorufin, produced by the enzymatic reaction, was detected. The detection limits for resorufin and IgA were 5.0μM and 16ng/mL, respectively. The photosensitivity of the OPD remained relatively constant for a minimum of one year.
Talanta 07/2012; 96:132-9. · 3.79 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: A surface plasmon resonance (SPR) sensor on a compact disk (CD)-type microfluidic device was developed to miniaturize the elements of a complete analytical system, pump and valves. The CD-type microfluidic device was fabricated by attaching a polydimethylsiloxane disk plate that contained microchannels and reservoirs to a flat polycarbonate disk plate that contained grating films with a thin layer of Au. The optical system of the SPR sensor and the theory for its operation are based on the principle of a grating coupled-type SPR. The sample and reagent solutions in the reservoirs on the CD-type microfluidic device were sequentially introduced into the detection chamber by centrifugal force generated by the rotation of the microfluidic device. The variation of resonance wavelength was dependent on the refractive index of the sample solution. This CD-type SPR sensor was successfully used in an immunoassay of immunoglobulin A (IgA). The anti-IgA, blocking reagent, sample and washing solution in the reservoirs were sequentially introduced into the detection chamber by changing the frequency of rotation of the microfluidic device. IgA in the sample solution was adsorbed to the anti-IgA immobilized on the Au thin layer in the detection chamber and was then detected by the SPR sensor.
Journal of Separation Science 09/2011; 34(20):2913-9. · 2.73 Impact Factor
-
Hizuru Nakajima,
Yukiko Okuma,
Kazuhiro Morioka,
Mayo Miyake, Akihide Hemmi,
Tatsuya Tobita,
Masayuki Yahiro,
Daisuke Yokoyama,
Chihaya Adachi,
Nobuaki Soh,
Koji Nakano,
Shuhua Xue,
Hulie Zeng,
Katsumi Uchiyama,
Toshihiko Imato
[show abstract]
[hide abstract]
ABSTRACT: A fluorescence detection system for a microfluidic device using an organic light-emitting diode (OLED) as the excitation light source and a charge-coupled device (CCD) as the photo detector was developed. The OLED was fabricated on a glass plate by photolithography and a vacuum deposition technique. The OLED produced a green luminescence with a peak emission at 512 nm and a half bandwidth of 55 nm. The maximum external quantum efficiency of the OLED was 7.2%. The emission intensity of the OLED at 10 mA/cm(2) was 13 μW (1.7 mW/cm(2)). The fluorescence detection system consisted of the OLED device, two band-pass filters, a five microchannel poly(dimethylsiloxane) (PDMS) microfluidic device and a linear CCD. The fluorescence detection system was successfully used in a flow-based enzyme-linked immunosorbent assay on a PDMS microfluidic device for the rapid determination of immunoglobulin A (IgA), a marker for human stress. The detection limit (S/N=3) for IgA was 16.5 ng/mL, and the sensitivity was sufficient for evaluating stress. Compared with the conventional 96-well microtiter plate assay, the analysis time and the amounts of reagent and sample solutions could all be reduced.
Journal of Separation Science 08/2011; 34(20):2906-12. · 2.73 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: A small-sized surface plasmon resonance (SPR) sensor with a microchip flow cell has been developed for the purpose of enhancing the sensitivity of the SPR detector for low molecular weight compounds. This portable differential SPR detector consisted of an LED, two cylindrical lenses, a round prism, a divided mirror, a CCD, electronics, and a polydimethylsiloxane/gold microchip with two flow paths (10mm long, 1mm wide, 20-100mum deep). 3-Mercaptopropyltrimethoxysilane was used for sealing the microchip. The performance of the on-site orientated SPR detector was estimated using sucrose and IgA. A drastic change in the SPR intensity appeared. The depth of the flow cell was in inverse proportion to the SPR intensity. Compared to a conventional flow cell having the size of 10mm (L)x1mm (W)x1mm (D), its sensitivity to 10% sucrose and 0.9nM IgA increased about 11 and 39 times, respectively. This phenomenon seemed to be due to the increase in the substance on the SPR sensor based on its size effect. These results showed that the application of the microchip sensor for SPR measurement has the possibility for improvement of the SPR intensity for low molecular substances.
Talanta 10/2006; 70(2):419-25. · 3.79 Impact Factor
-
Masatoshi Kobayashi,
Masahiro Sato,
Yan Li,
Nobuaki Soh,
Koji Nakano,
Kiyoshi Toko,
Norio Miura,
Kiyoshi Matsumoto, Akihide Hemmi,
Yasukazu Asano,
Toshihiko Imato
[show abstract]
[hide abstract]
ABSTRACT: A surface plasmon resonance (SPR) immunosensor based on a competitive immunoreaction for the determination of trinitrophenol (TNP) is described. A goat anti-mouse IgG (1st antibody), which recognizes an Fc moiety of an antibody, was immobilized on a gold film of an SPR sensor chip by physical adsorption. A TNP solution containing a fixed concentration of a mouse anti-TNP monoclonal antibody (2nd antibody) and a TNP-keyhole limpet hemocyanin (KLH) conjugate was incubated in one-pot and introduced into the sensor chip. The TNP-KLH conjugate competes with TNP for binding with the 2nd antibody. The resulting complex of the 2nd antibody with the TNP-KLH conjugate was bound to the 1st antibody, which is immobilized on the sensor chip. The SPR sensor signal based on resonance angle shift is dependent on the concentration of TNP in the incubation solution in the range from 25ppt to 25ppb, and the coefficient of variation of the SPR signals for the 25ppb TNP solution was determined to be 13% (n=4). The experimental results for the adsorption constant of the 1st antibody on the sensor chip and the binding constant of the 1st antibody complex with the 2nd antibody are discussed, together with theoretical considerations.
Talanta 01/2006; 68(2):198-206. · 3.79 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: A simple flow injection analysis (FIA) system for residual chlorine in tap water has been developed by using a Pb(II) ion-selective electrode (ISE) detector. The method is based on a specific response of the Pb(II)-ISE to residual chlorine. The FIA system consists of a millivolt meter, a peristaltic pump, a Pb(II)-ISE detector and a recorder. A linear working curve between peak height and concentration of residual chlorine was obtained from 0.1 to 1 mg l−1 for the developed FIA system. The relative standard deviation for repeated injections of a 0.2 mg l−1 residual chlorine sample was 2%. The regression line and its correlation factor between the conventional o-tolidine colorimetric method and the present method were Y=0.75X+0.17 and 0.967, respectively, for this determination.
Talanta.