Publications (2)4.82 Total impact
-
Article: [Neointimal tissue proliferation after coronary stent implantation without predilatation].
[show abstract] [hide abstract]
ABSTRACT: Intravascular ultrasound (IVUS) studies in conventional stent angioplasty with predilatation have demonstrated that late luminal narrowing is caused by neointimal proliferation. In the present study, we analyzed the degree and distribution of in-stent neointimal proliferation after direct stent implantation and aimed to identify variables that predict a proliferative response. We studied 45 patients who underwent successful stent implantation without predilatation and 23 patients with similar clinical and angiographic characteristics who underwent conventional stent angioplasty with predilatation. IVUS imaging was performed at 7.85+/-2.81 months. The cross-sectional area was measured at five predetermined points in the stented coronary segment. The inflation pressure used in patients who underwent direct stent implantation was higher than that employed in those who underwent conventional angioplasty with predilatation (13+/-3 atm vs 10+/-2 atm; P=.005). Luminal and stent cross-sectional areas were greater in the group that did not undergo predilatation than in the group that did. Neointimal proliferation in the 5 sections analyzed along the axis of the stent was similar in the 2 groups. There was a weak linear relationship between the amount of plaque outside the stent and neointimal proliferation in both the group that underwent predilatation (r=0.37; P=.005) and the group that did not (r=0.33; P=.005). As with conventional angioplasty, the neointimal proliferation that occurred after direct stent implantation showed a diffuse homogeneous pattern along the length of the stent. There was a weak correlation between this proliferative response and the amount of plaque outside the stent.Revista Espa de Cardiologia 10/2005; 58(9):1045-53. · 2.53 Impact Factor -
Article: Influence of residual stenosis in determining restenosis after cutting balloon angioplasty
[show abstract] [hide abstract]
ABSTRACT: The cutting balloon is a new device for coronary angioplasty, which, by the combination of incision and dilatation of the plaque, is believed to minimize arterial wall trauma, the neoproliferative response, and subsequent restenosis. In this study, we sought to determine predictors of the restenosis using this technique. Seventy-seven patients underwent successful coronary angioplasty with cutting balloon alone. In 67 of these patients (87%), we performed a control angiogram at 6-month follow-up. Pre-, post-, and late angiographic results were evaluated by quantitative coronary analysis. Clinical and angiographic variables were correlated with restenosis as a binary variable and a continuous variable (late loss and late minimum luminal diameter). Univariate analysis showed that the immediate postprocedure minimum luminal diameter (MLD) was smaller in the restenotic group (defined as MLD > 50% by quantitative coronary angiography) than in the nonrestenotic group (1.90 ± 0.47 mm vs. 2.19 ± 0.56 mm, P < 0.05). In addition, the immediate percentage of stenosis was higher in the restenotic group than in the nonrestenotic group (37% ± 10% vs. 27% ± 11%, P < 0.003). Multivariate analysis identified the immediate postcutting balloon percentage of stenosis as an independent determinant of binary restenosis (P < 0.008). When restenosis was defined as a continuous variable, the immediate postprocedure MLD was an independent predictor of late loss (P < 0.02) and of late MLD (P < 0.0002). No clinical, preprocedure angiographic, or technical variables tested were associated with restenosis. The degree of postprocedural residual stenosis after cutting balloon angioplasty is predictive of late restenosis. Cathet. Cardiovasc. Intervent. 49:410–414, 2000. © 2000 Wiley-Liss, Inc.Catheterization and Cardiovascular Interventions 03/2000; 49(4):410 - 414. · 2.29 Impact Factor