-
[show abstract]
[hide abstract]
ABSTRACT: We created volumetric-modulated arc therapy (VMAT) plans for portal vein tumor thrombus (PVTT) in hepatocellular carcinoma, and compared the results with those from three-dimensional conformal radiotherapy (3D-CRT) and rotational conformal radiotherapy (R-CRT) plans. CT scan data from 10 consecutive patients with PVTT treated with 3D-CRT between January 2008 and January 2010 were utilized in the analysis. We analyzed the dosimetric properties of the plans for the 10 patients using the three different techniques with three different isocenter doses of 50, 56 and 60 Gy in 2-Gy fractions. The D95, Dmean, homogeneity index and conformity index were compared for the planning target volume (PTV). The Dmean, V20 and V30 were also compared for normal livers. The monitor units (MUs) and the treatment time were also evaluated. The normal liver V30 for VMAT was significantly less than that for 3D-CRT for the prescribed doses of 56 and 60 Gy (P < 0.05). It was also found that the normal liver V30 resulting from 3D-CRT was prohibitively increased when the prescribed dose was increased in two steps. For PTV D95, we found no significant differences between the three techniques for the 50- and 56-Gy prescriptions, or between VMAT and the other techniques for the 60-Gy prescription. The differences in the MUs and treatment times were not statistically significant between VMAT and 3D-CRT. We have demonstrated that VMAT may be a more advantageous technique for dose escalation reaching 60 Gy in the treatment of PVTT due to the reduced normal liver V30.
Journal of Radiation Research 02/2013; · 1.68 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: We created volumetric modulated arc therapy (VMAT) plans for 31 prostate cancer patients using one of three treatment planning systems (TPSs)-ERGO++, Monaco, or Pinnacle-and then treated those patients. A dose of 74 Gy was prescribed to the planning target volume (PTV). The rectum, bladder, and femur were chosen as organs at risk (OARs) with specified dose-volume constraints. Dose volume histograms (DVHs), the mean dose rate, the beam-on time, and early treatment outcomes were evaluated and compared. The DVHs calculated for the three TPSs were comparable. The mean dose rates and beam-on times for Ergo++, Monaco, and SmartArc were, respectively, 174.3 ± 17.7, 149.7 ± 8.4, and 185.8 ± 15.6 MU/min and 132.7 ± 8.4, 217.6 ± 13.1, and 127.5 ± 27.1 sec. During a follow-up period of 486.2 ± 289.9 days, local recurrence was not observed, but distant metastasis was observed in a single patient. Adverse events of grade 3 to grade 4 were not observed. The mean dose rate for Monaco was significantly lower than that for ERGO++ and SmartArc (P < 0.0001), and the beam-on time for Monaco was significantly longer than that for ERGO++ and SmartArc (P < 0.0001). Each TPS was successfully used for prostate VMAT planning without significant differences in early clinical outcomes despite significant TPS-specific delivery parameter variations.
TheScientificWorldJOURNAL 01/2013; 2013:289809. · 1.66 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: The aim of this study was to update data of radiation therapy regimens for improvement in local control in patients with limited-stage small cell lung cancer, a retrospective study was conducted.
Results of early concurrent chemoradiotherapy with accelerated hyperfractionation in 30 patients between 1998 and 2005 were retrospectively reviewed. The prescribed dose was 45 Gy in 30 fractions in all patients.
All patients received a full dose of radiation therapy; however, interruptions for >or=5 days, mainly due to hematologic toxicity, were required in 18 patients (60%). The 5-year Kaplan-Meier survival rate and the median survival time were 26% and 26 months, respectively. The 4-year in-field control rate was 56%. Sites of relapse were local relapse in 9 patients (6 for in-field relapse, 3 for marginal relapse) and distant metastases in 16 patients (11 for distant metastases only, 5 for distant metastases with local relapse). The sites of marginal relapse were the upper margin in two patients and the peripheral margin in one patient. Grade 3 radiation esophagitis was observed in only three patients.
Because in-field control was insufficient, a more effective approach should be sought to provide better local control.
Japanese journal of radiology 01/2010; 28(1):43-7. · 0.65 Impact Factor