-
[show abstract]
[hide abstract]
ABSTRACT: Automated patch clamping addresses the need for high-throughput screening of chemical entities that alter ion channel function. As a result, there is considerable utility in the pharmaceutical screening arena for novel platforms that can produce relevant data both rapidly and consistently. Here we present results that were obtained with an innovative microfluidic automated patch clamp system utilizing a well-plate that eliminates the necessity of internal robotic liquid handling. Continuous recording from cell ensembles, rapid solution switching, and a bench-top footprint enable a number of assay formats previously inaccessible to automated systems. An electro-pneumatic interface was employed to drive the laminar flow of solutions in a microfluidic network that delivered cells in suspension to ensemble recording sites. Whole-cell voltage clamp was applied to linear arrays of 20 cells in parallel utilizing a 64-channel voltage clamp amplifier. A number of unique assays requiring sequential compound applications separated by a second or less, such as rapid determination of the agonist EC(50) for a ligand-gated ion channel or the kinetics of desensitization recovery, are enabled by the system. In addition, the system was validated via electrophysiological characterizations of both voltage-gated and ligand-gated ion channel targets: hK(V)2.1 and human Ether-à-go-go-related gene potassium channels, hNa(V)1.7 and 1.8 sodium channels, and (α1) hGABA(A) and (α1) human nicotinic acetylcholine receptor receptors. Our results show that the voltage dependence, kinetics, and interactions of these channels with pharmacological agents were matched to reference data. The results from these IonFlux™ experiments demonstrate that the system provides high-throughput automated electrophysiology with enhanced reliability and consistency, in a user-friendly format.
Assay and Drug Development Technologies 05/2012; 10(4):313-24. · 1.73 Impact Factor
-
Andrew P Golden,
Nianzhen Li,
Qin Chen,
Tony Lee, Tanner Nevill,
Xueying Cao,
Juliette Johnson,
Gül Erdemli,
Cristian Ionescu-Zanetti,
Laszlo Urban,
Mats Holmqvist
[show abstract]
[hide abstract]
ABSTRACT: Ion channel assays are essential in drug discovery, not only for identifying promising new clinical compounds, but also for minimizing the likelihood of potential side effects. Both applications demand optimized throughput, cost, and predictive accuracy of measured membrane current changes evoked or modulated by drug candidates. Several competing electrophysiological technologies are available to address this demand, but important gaps remain. We describe the industrial application of a novel microfluidic-based technology that combines compounds, cells, and buffers on a single, standard well plate. Cell trapping, whole cell, and compound perfusion are accomplished in interconnecting microfluidic channels that are coupled to pneumatic valves, which emancipate the system from robotics, fluidic tubing, and associated maintenance. IonFlux™ is a state-of-the-art, compact system with temperature control and continuous voltage clamp for potential application in screening for voltage- and ligand-gated ion channel modulators. Here, ensemble recordings of the IonFlux system were validated with the human Ether-à-go-go related gene (hERG) channel (stably expressed in a Chinese hamster ovary cell line), which has established biophysical and pharmacological characteristics in other automated planar patch systems. We characterized the temperature dependence of channel activation and its reversal potential. Concentration response characteristics of known hERG blockers and control compounds obtained with the IonFlux system correlated with literature and internal data obtained on this cell line with the QPatch HT system. Based on the biophysical and pharmacological data, we conclude that the IonFlux system offers a novel, versatile, automated profiling, and screening system for ion channel targets with the benefit of temperature control.
Assay and Drug Development Technologies 05/2011; 9(6):608-19. · 1.73 Impact Factor
-
[show abstract]
[hide abstract]
ABSTRACT: Platelet aggregation occurs in response to vascular injury where the extracellular matrix below the endothelium has been exposed. The platelet adhesion cascade takes place in the presence of shear flow, a factor not accounted for in conventional (static) well-plate assays. This article reports on a platelet-aggregation assay utilizing a microfluidic well-plate format to emulate physiological shear flow conditions. Extracellular proteins, collagen I or von Willebrand factor are deposited within the microfluidic channel using active perfusion with a pneumatic pump. The matrix proteins are then washed with buffer and blocked to prepare the microfluidic channel for platelet interactions. Whole blood labeled with fluorescent dye is perfused through the channel at various flow rates in order to achieve platelet activation and aggregation. Inhibitors of platelet aggregation can be added prior to the flow cell experiment to generate IC50 dose response data.
Journal of Visualized Experiments 01/2009;