Emanuela Leoni

Fondazione Salvatore Maugeri IRCCS, Pavia, Lombardy, Italy

Are you Emanuela Leoni?

Claim your profile

Publications (3)7.29 Total impact

  • Source
    Article: Serum pharmacokinetics in patients treated with transarterial chemoembolization (TACE) using two types of epirubicin-loaded microspheres.
    [show abstract] [hide abstract]
    ABSTRACT: The purpose of this study was the pharmacokinetic (PK) profile assessment in the serum of patients affected by hepatocellular carcinoma (HCC) treated with transarterial chemoembolization (TACE) with drug-eluting beads. This study included 20 patients, 12 treated with DC Bead® and 8 with HepaSphere Microsphere®, preloaded with epirubicin. No patient randomization was used for the inclusion in one group or in the other. Peripheral blood samples were obtained from all patients after the treatment, until 24 hours past the procedure. The pharmacokinetic study showed low peak serum epirubicin concentrations with greater drug exposure for the DC Bead® group (p<0.05). The highest drug concentration after microsphere injection was observed at 5 minutes in all 20 patients. In the time interval between 1 and 24 hours after TACE, persisting levels of epirubicin were detected in peripheral blood samples. A persistent and sustained drug elution for both types of microparticles was found.
    Anticancer research 05/2012; 32(5):1769-74. · 1.73 Impact Factor
  • Source
    Article: Validation of an LC-MS/MS method for the determination of epirubicin in human serum of patients undergoing drug eluting microsphere-transarterial chemoembolization (DEM-TACE).
    [show abstract] [hide abstract]
    ABSTRACT: Drug Eluting Microsphere-Transarterial Chemoembolization (DEM-TACE) is a new delivery system to administrate drugs in a controlled manner useful for application in the chemoembolization of colorectal cancer metastases to the liver. DEM-TACE is focused to obtain higher concentrations of the drug to the tumor with lower systemic concentrations than traditional cancer chemotherapy. Therefore a specific, precise and sensitive LC-ESI-MS/MS assay procedure was properly designed to detect and quantify epirubicin at the concentrations expected from a transarterial chemoembolization with microspheres. Serum samples were kept acidic (pH approximately of 3.5) and sample preparation consisted of a solid phase extraction (SPE) procedure with HLB OASIS cartridges using a methylene chloride/2-propanol/methanol mixture solution to recover epirubicin. The analyses consisted of reversed-phase high-performance liquid chromatography (rp-HPLC) coupled with tandem mass spectrometry (MS/MS). Accuracy, precision and matrix effect of this procedure were carried out by analyzing four quality control samples (QCs) on five separate days. The validation parameters were assessed by recovery studies of spiked serum samples. Recoveries were found to vary between 92 and 98% at the QC levels (5, 40, 80 and 150 microg/L) with relative standard deviation (RSD) always less than 3.7%. The limit of detection (LOD) was set at 1 microg/L. The developed procedure has been also applied to investigate the different capability of two types of commercially available microspheres to release epirubicin into the human circulatory system.
    Journal of chromatography. B, Analytical technologies in the biomedical and life sciences 09/2009; 877(29):3543-8. · 2.78 Impact Factor
  • Article: Simultaneous determination of cyclophosphamide, ifosfamide, doxorubicin, epirubicin and daunorubicin in human urine using high-performance liquid chromatography/electrospray ionization tandem mass spectrometry: bioanalytical method validation.
    [show abstract] [hide abstract]
    ABSTRACT: A reversed-phase high-performance liquid chromatography (rp-HPLC) system interfaced with an electrospray ionization (ESI) source coupled to tandem mass spectrometry (MS/MS) was developed and validated for the determination of cyclophosphamide (CP), ifosfamide (IF), daunorubicin (DNR), doxorubicin (DXR), and epirubicin (EPI) in human urine. The analysis of samples containing multiple analytes with a dissimilar range of polarities was carried out using a conventional reversed-phase chromatographic BDS Hypersil C8 column. The analytical run was 15 min. The triple quadrupole mass spectrometer was operated in positive ion mode and multiple reaction monitoring (MRM) was used for drug quantification. The method was validated over a concentration range of 0.2 to 4.0 microg.L(-1) for CP, IF, DXR, EPI and 0.15-2.0 microg.L(-1) for DNR in human urine. The lower limit of quantification (LLOQ) was 0.2 microg.L(-1) for CP, IF, EPI and was set at 0.3 and 0.15 microg.L(-1) for DXR and DNR, respectively. The relative standard deviations (RSD%) were <11.2% for inter- and intra-day precisions. The overall accuracy was also within 114.7% for all analytes at the concentrations of the quality control samples. The potential of ionization suppression resulting from the endogenous biological material on the rp-HPLC/MS/MS method was evaluated and measured. The feasibility of the proposed HPLC/ESI-MS/MS procedure was demonstrated by analyzing urine samples from pharmacy technicians and nurses working in hospitals or personnel employed in drug-manufacturing plants.
    Rapid Communications in Mass Spectrometry 09/2008; 22(17):2645-59. · 2.79 Impact Factor