Are you A. De Sio?

Claim your profile

Publications (3)0 Total impact

  • Article: Fast IR Array Detector for Transverse Beam Diagnostics at DA{\Phi}NE
    [show abstract] [hide abstract]
    ABSTRACT: At the Laboratori Nazionali di Frascati of the National Institute of Nuclear Physics (INFN) an infrared (IR) array detector with fast response time has been built and assembled in order to collect the IR image of e-/e+ sources of the DA{\Phi}NE collider. Such detector is made by 32 bilinear pixels with an individual size of 50x50 {\mu}m2 and a response time of ~1 ns. In the framework of an experiment funded by the INFN Vth Committee dedicated to beam diagnostics, the device with its electronic board has been tested and installed on the DA{\Phi}NE positron ring. A preliminary characterization of few pixels of the array and of the electronics has been carried out at the IR beamline SINBAD at DA{\Phi}NE. In particular the detection of the IR source of the e- beam has been observed using four pixels of the array acquiring signals simultaneously with a four channels scope at 1 GHz and at 10 Gsamples/s. The acquisition of four pixels allowed monitoring in real time differences in the bunch signals in the vertical direction. A preliminary analysis of data is presented and discussed. In particular we will outline the correlation between signals and displacements of the source occurring with bunch refilling during a complete shift of DA{\Phi}NE. Comment: 3 pages, 4 figures, poster presented to IPAC'10 - Kyoto - May 24-28 2010
    06/2010;
  • Source
    Article: Beam diagnostics at DAFNE with fast uncooled IR detectors
    [show abstract] [hide abstract]
    ABSTRACT: Bunch-by-bunch longitudinal diagnostics is a key issue of modern accelerators. To face up this challenging demand, tests of mid-IR compact uncooled photoconductive HgCdTe detectors have been recently performed at DAFNE. Different devices were used to monitor the emission of e- bunches. The first experiments allowed recording of 2.7 ns long e- bunches with a FWHM of a single pulse of about 600 ps. These results address the possibility to improve diagnostics at DAFNE and to this purpose an exit port on a bending magnet of the positron ring has been set-up. An HV chamber, hosting a gold-coated plane mirror that collects and deflects the radiation through a ZnSe window, is the front-end of this port. After the window, a simple optical layout in air allows focusing IR radiation on different detectors. The instrumentation will allow comparison in the sub-ns time domain between the two rings and to identify and characterize bunch instabilities. Moreover, to improve performances tests of new photovoltaic detectors with sub-ns response times are in progress. We will briefly summarize the actual status of the 3+L experiment and will discuss future applications of fast IR photovoltaic detectors and the development of fast IR array detectors.
    07/2008;
  • Article: Fast infrared detectors for beam diagnostics with synchrotron radiation
    [show abstract] [hide abstract]
    ABSTRACT: Beam diagnostic is a fundamental constituent of any particle accelerators either dedicated to high-energy physics or to synchrotron radiation experiments. All storage rings emit radiations. Actually they are high brilliant sources of radiation: the synchrotron radiation emission covers from the infrared range to the X-ray domain with a pulsed structure depending on the temporal characteristics of the stored beam. The time structure of the emitted radiation is extremely useful as a tool to perform time-resolved experiments. However, this radiation can be also used for beam diagnostic to determine the beam stability and to measure the dimensions of the e− or e+ beam. Because of the temporal structure of the synchrotron radiation to perform diagnostic, we need very fast detectors. Indeed, the detectors required for the diagnostics of the stored particle bunches at third generation synchrotron radiation sources and FEL need response times in the sub-ns and even ps range. To resolve the bunch length and detect bunch instabilities, X-ray and visible photon detectors may be used achieving response times of a few picoseconds. Recently, photon uncooled infrared devices optimized for the mid-IR range realized with HgCdTe semiconductors allowed to obtain sub-nanosecond response times. These devices can be used for fast detection of intense IRSR sources and for beam diagnostic. We present here preliminary experimental data of the pulsed synchrotron radiation emission of DAΦNE, the electron positron collider of the LNF laboratory of the INFN, performed with new uncooled IR detectors with a time resolution of a few hundreds of picoseconds.
    Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment.