Are you Catherine Geniets?

Claim your profile

Publications (2)3.65 Total impact

  • Article: Evaluation of clinical image processing algorithms used in digital mammography.
    [show abstract] [hide abstract]
    ABSTRACT: Screening is the only proven approach to reduce the mortality of breast cancer, but significant numbers of breast cancers remain undetected even when all quality assurance guidelines are implemented. With the increasing adoption of digital mammography systems, image processing may be a key factor in the imaging chain. Although to our knowledge statistically significant effects of manufacturer-recommended image processings have not been previously demonstrated, the subjective experience of our radiologists, that the apparent image quality can vary considerably between different algorithms, motivated this study. This article addresses the impact of five such algorithms on the detection of clusters of microcalcifications. A database of unprocessed (raw) images of 200 normal digital mammograms, acquired with the Siemens Novation DR, was collected retrospectively. Realistic simulated microcalcification clusters were inserted in half of the unprocessed images. All unprocessed images were subsequently processed with five manufacturer-recommended image processing algorithms (Agfa Musica 1, IMS Raffaello Mammo 1.2, Sectra Mamea AB Sigmoid, Siemens OPVIEW v2, and Siemens OPVIEW v1). Four breast imaging radiologists were asked to locate and score the clusters in each image on a five point rating scale. The free-response data were analyzed by the jackknife free-response receiver operating characteristic (JAFROC) method and, for comparison, also with the receiver operating characteristic (ROC) method. JAFROC analysis revealed highly significant differences between the image processings (F = 8.51, p < 0.0001), suggesting that image processing strongly impacts the detectability of clusters. Siemens OPVIEW2 and Siemens OPVIEW1 yielded the highest and lowest performances, respectively. ROC analysis of the data also revealed significant differences between the processing but at lower significance (F = 3.47, p = 0.0305) than JAFROC. Both statistical analysis methods revealed that the same six pairs of modalities were significantly different, but the JAFROC confidence intervals were about 32% smaller than ROC confidence intervals. This study shows that image processing has a significant impact on the detection of microcalcifications in digital mammograms. Objective measurements, such as described here, should be used by the manufacturers to select the optimal image processing algorithm.
    Medical Physics 03/2009; 36(3):765-75. · 2.83 Impact Factor
  • Article: Clinical image quality criteria for full field digital mammography: a first practical application.
    [show abstract] [hide abstract]
    ABSTRACT: In order to quantify the clinical quality of full-field digital mammography, a set of image quality parameters is developed. The set consisted of 12 image quality criteria and 8 physical characteristics of the image. The first set interrogates the visibility of anatomical structures and typical characteristics of a digital image, such as noise and saturation of dark and white areas. The second set of criteria evaluates contrast, sharpness and confidence with the representation of masses, microcalcifications and the image. The use of these criteria is reported in a retrospective study, in which the impact of dose on the radiological quality of digital mammograms is evaluated. Fifty patients acquired in a low-dose mode were retrieved and compared with 50 patients acquired in a dose mode that was set 41% higher. The dose affects, more than expected, contrast and sharpness of the image, whereas the visibility of the anatomical structures remains unchanged. With these parameters, quantification of the image quality is possible; however, because of subjectivity of the parameters, only intra-observer comparison and evaluation of the individual parameters rather than the overall results are advised. Together with physical tests of image quality, critical radiological evaluation of the quality should be included in the acceptance process of digital mammography.
    Radiation Protection Dosimetry 04/2008; 129(1-3):265-70. · 0.82 Impact Factor