    Article: Efficacy and safety of Technosphere inhaled insulin compared with Technosphere powder placebo in insulin-naive type 2 diabetes suboptimally controlled with oral agents.
    [show abstract] [hide abstract]
    ABSTRACT: This double-blind, placebo-controlled, randomized, multicenter, parallel-group study compared the efficacy, safety, and tolerability of Technosphere insulin with Technosphere powder as placebo in insulin-naive type 2 diabetic patients whose diabetes was suboptimally controlled with oral antidiabetic agents. Patients (n = 126) were randomly assigned to 12 weeks of therapy with Technosphere insulin or Technosphere powder after lifestyle education on nutrition, exercise, and instructions on inhaler use. The primary efficacy outcome was change in A1C from baseline to study end, and the secondary efficacy outcome was area under the curve for postprandial glucose levels during a meal test at treatment weeks 4, 8, and 12. A1C reduction from a mean baseline of 7.9% was greater with Technosphere insulin than with Technosphere powder (-0.72 vs. -0.30%; P = 0.003). Postprandial glucose excursions were reduced by 56% with Technosphere insulin compared with baseline, and maximal postprandial glucose levels were reduced by 43% compared with Technosphere powder. Incidences of hypoglycemia, hyperglycemia, cough, and other adverse events were low in both groups. Body weight was unchanged in both groups. Technosphere insulin was well tolerated and demonstrated significant improvement in glycemic control with clinically meaningful reductions in A1C levels and postprandial glucose concentrations after 12 weeks of treatment.
    Diabetes care 09/2008; 31(11):2177-82. · 8.09 Impact Factor
  • Article: Randomized forced titration to different doses of technosphere insulin demonstrates reduction in postprandial glucose excursions and hemoglobin A1c in patients with type 2 diabetes.
    [show abstract] [hide abstract]
    ABSTRACT: Individuals with type 2 diabetes mellitus have impairments in early insulin release, resulting in increased postprandial glucose excursions and suboptimal glycemic control. Studies with Technosphere Insulin (TI) indicate that it has rapid systemic absorption and a short duration of glucose-lowering activity, making it well suited for controlling postprandial glucose levels. The goal of this phase 2b, prospective, multicenter, double-blind, placebo-controlled study was to characterize the dose response of four different doses (equivalent to 3.6, 7.3, 10.9, and 14.6 U subcutaneous regular human insulin) of prandial TI or Technosphere powder alone administered before each of three meals daily, in combination with insulin glargine over an 11-week treatment period, in patients with type 2 diabetes and suboptimal glycemic control. The study enrolled 227 patients. In all dose groups, TI demonstrated statistically significant dose-dependent reductions in hemoglobin A1c (HbA1c) versus baseline (-0.4, -0.5, -0.5, and -0.6 for 3.6, 7.3, 10.9, and 14.6 U equivalents, respectively; p < 0.05 in all groups), as well as versus placebo or Technosphere powder alone (-0.40, -0.67, -0.70, and -0.78 for 3.6, 7.3, 10.9, and 14.6 U equivalents, respectively; p < 0.04 in all groups). It reduced the postprandial maximum glucose concentration within each treatment group (statistically significant in all but the TI 3.6 U-equivalent group) and reduced the postprandial area under the glucose curve (statistically significant for the TI 10.9 and 14.6 U-equivalent groups) versus placebo. There were no cases of severe hypoglycemia, while mild/moderate hypoglycemia was observed most frequently in the highest dosage groups, as expected. Rates of cough were low and comparable among all groups. No clinically relevant changes in pulmonary function tests, body weight, or high-resolution computerized axial tomography and magnetic resonance imaging were observed. This study demonstrated that, over 11 weeks, TI plus basal insulin glargine is well tolerated and results in dose-dependent reductions in postprandial glucose and HbA1c levels.
    Journal of diabetes science and technology 01/2008; 2(1):47-57.