Are you Rui Pereira?

Claim your profile

Publications (7)0 Total impact

  • Article: Cosmic ray velocity and electric charge measurements with the AMS/RICH detector: prototype results
    [show abstract] [hide abstract]
    ABSTRACT: The Alpha Magnetic Spectrometer (AMS) to be installed on the International Space Station (ISS) will measure charged cosmic ray spectra of elements up to iron, in the rigidity range from 1 GV to 1 TV, for at least three years. AMS is a large angular spectrometer composed of different subdetectors, including a proximity focusing Ring Imaging CHerenkov (RICH) detector. This will be equipped with a mixed radiator made of aerogel and sodium fluoride (NaF), a lateral conical mirror and a detection plane made of 680 photomultipliers coupled to light guides. The RICH detector allows measurements of particle's electric charge up to iron, and particle's velocity. Two possible methods for reconstructing the Cherenkov angle and the electric charge with the RICH will be discussed. A RICH prototype consisting of a detection matrix with 96 photomultipliers, a segment of a conical mirror and samples of the radiator materials was built and its performance was evaluated using ion beam data. Results from the last test beam performed with ion fragments resulting from the collision of a 158 GeV/c/nucleon primary beam of indium ions (CERN SPS) on a lead target are reported. The large amount of collected data allowed to test and characterize different aerogel samples and the NaF radiator. In addition, the reflectivity of the mirror was evaluated. The data analysis confirms the design goals.
    03/2008;
  • Source
    Article: AMS - a magnetic spectrometer on the international space station
    [show abstract] [hide abstract]
    ABSTRACT: The Alpha Magnetic Spectrometer (AMS) is a particle detector, designed to search for cosmic antimatter and dark matter and to study the elemental and isotopic composition of primary cosmic rays, that will be installed on the International Space Station (ISS) in 2008 to operate for at least three years. The detector will be equipped with a ring imaging Cherenkov detector (RICH) enabling measurements of particle electric charge and velocity with unprecedented accuracy. Physics prospects and test beam results are shortly presented.
    03/2008;
  • Source
    Article: Isotopic mass separation with the RICH detector of the AMS Experiment
    [show abstract] [hide abstract]
    ABSTRACT: The Alpha Magnetic Spectrometer (AMS) to be installed on the International Space Station (ISS) will be equipped with a proximity focusing Ring Imaging Cerenkov detector (RICH). Reconstruction of the Cerenkov angle and the electric charge with RICH are discussed. A likelihood method for the Cerenkov angle reconstruction was applied leading to a velocity determination for protons with a resolution around 0.1%. The electric charge reconstruction is based on the counting of the number of photoelectrons and on an overall efficiency estimation on an event-by-event basis. The isotopic mass separation of helium and beryllium is presented.
    03/2008;
  • Source
    Article: Particle identification with the AMS-02 RICH detector: D/p and anti-D/anti-p separation
    [show abstract] [hide abstract]
    ABSTRACT: The Alpha Magnetic Spectrometer (AMS), whose final version AMS-02 is to be installed on the International Space Station (ISS) for at least 3 years, is a detector designed to measure charged cosmic ray spectra with energies up to the TeV region and with high energy photon detection capability up to a few hundred GeV, using state-of-the art particle identification techniques. Among several detector subsystems, AMS includes a proximity focusing RICH enabling precise measurements of particle electric charge and velocity. The combination of both these measurements together with the particle rigidity measured on the silicon tracker endows a reliable measurement of the particle mass. The main topics of the AMS-02 physics program include detailed measurements of the nuclear component of the cosmic-ray spectrum and the search for indirect signatures of dark matter. Mass separation of singly charged particles, and in particular the separation of deuterons and antideuterons from massive backgrounds of protons and antiprotons respectively, is essential in this context. Detailed Monte Carlo simulations of AMS-02 have been used to evaluate the detector's performance for mass separation at different energies. The obtained results and physics prospects are presented.
    02/2008;
  • Source
    Article: Particle identification with the AMS-02 RICH detector: search for dark matter with antideuterons
    [show abstract] [hide abstract]
    ABSTRACT: The Alpha Magnetic Spectrometer (AMS), whose final version AMS-02 is to be installed on the International Space Station (ISS) for at least 3 years, is a detector designed to measure charged cosmic ray spectra with energies up to the TeV region and with high energy photon detection capability up to a few hundred GeV, using state-of-the art particle identification techniques. It is equipped with several subsystems, one of which is a proximity focusing Ring Imaging Cherenkov (RICH) detector equipped with a dual radiator (aerogel+NaF), a lateral conical mirror and a detection plane made of 680 photomultipliers and light guides, enabling precise measurements of particle electric charge and velocity (Delta beta / beta ~ 10^-3 and 10^-4 for Z=1 and Z=10-20, respectively) at kinetic energies of a few GeV/nucleon. Combining velocity measurements with data on particle rigidity from the AMS-02 Tracker (Delta R / R ~ 2% for R=1-10 GV) it is possible to obtain a reliable measurement for particle mass. One of the main topics of the AMS-02 physics program is the search for indirect signatures of dark matter. Experimental data indicate that dark, non-baryonic matter of unknown composition is much more abundant than baryonic matter, accounting for a large fraction of the energy content of the Universe. Apart from antideuterons produced in cosmic-ray propagation, the annihilation of dark matter will produce additional antideuteron fluxes. Detailed Monte Carlo simulations of AMS-02 have been used to evaluate the detector's performance for mass separation, a key issue for anti-D/anti-p separation. Results of these studies are presented.
    11/2007;
  • Source
    Article: Isotope separation with the RICH detector of the AMS Experiment
    [show abstract] [hide abstract]
    ABSTRACT: The Alpha Magnetic Spectrometer (AMS), to be installed on the International Space Station (ISS) in 2008, is a cosmic ray detector with several subsystems, one of which is a proximity focusing Ring Imaging Cherenkov (RICH) detector. This detector will be equipped with a dual radiator (aerogel+NaF), a lateral conical mirror and a detection plane made of 680 photomultipliers and light guides, enabling precise measurements of particle electric charge and velocity. Combining velocity measurements with data on particle rigidity from the AMS Tracker it is possible to obtain a measurement for particle mass, allowing the separation of isotopes. A Monte Carlo simulation of the RICH detector, based on realistic properties measured at ion beam tests, was performed to evaluate isotope separation capabilities. Results for three elements -- H (Z=1), He (Z=2) and Be (Z=4) -- are presented.
    11/2007;
  • Article: The Ring Imaging Cherenkov detector of the AMS experiment: test beam results with a prototype
    [show abstract] [hide abstract]
    ABSTRACT: The Alpha Magnetic Spectrometer (AMS) to be installed on the International Space Station (ISS) will be equipped with a proximity Ring Imaging Cherenkov (RICH) detector for measuring the velocity and electric charge of the charged cosmic particles. This detector will contribute to the high level of redundancy required for AMS as well as to the rejection of albedo particles. Charge separation up to iron and a velocity resolution of the order of 0.1% for singly charged particles are expected. A RICH protoptype consisting of a detection matrix with 96 photomultiplier units, a segment of a conical mirror and samples of the radiator materials was built and its performance was evaluated. Results from the last test beam performed with ion fragments resulting from the collision of a 158 GeV/c/nucleon primary beam of indium ions (CERN SPS) on a lead target are reported. The large amount of collected data allowed to test and characterize different aerogel samples and the sodium fluoride radiator. In addition, the reflectivity of the mirror was evaluated. The data analysis confirms the design goals.
    Nuclear Physics B - Proceedings Supplements.

Top co-authors