Are you Friederike Schwarz?

Claim your profile

Publications (2)6.98 Total impact

  • Article: Cisternal segments of the glossopharyngeal, vagus, and accessory nerves: detailed magnetic resonance imaging-demonstrated anatomy and neurovascular relationships.
    [show abstract] [hide abstract]
    ABSTRACT: The aim of this study was to determine whether high-resolution MR imaging is suitable for identifying and differentiating among the nerve root bundles of the glossopharyngeal (cranial nerve [CN] IX), vagus (CN X), and accessory nerves (CN XI) as well as any adjacent vessels. Twenty-five patients (50 sides) underwent MR imaging using the 3D constructive interference in steady-state (CISS) sequence, as well as noncontrast and contrast-enhanced 3D time-of-flight (TOF) MR angiography. Two individuals scored these studies by consensus to determine how well these sequences displayed the neurovascular contacts and nerve root bundles of CNs IX and X and the cranial and spinal roots of CN XI. Landmarks useful for identifying each lower CN were specifically sought. The 3D CISS sequence successfully depicted CNs IX and X in 100% of the sides. Nerve root bundles of the cranial segment of CN XI were identified in 88% of the sides and those of the spinal segment of CN XI were noted in 93% of the sides. Landmarks useful in identifying the lower CNs included the vagal trigone, the choroid plexus of the lateral recess, the glossopharyngeal and vagal meatus, the inferior petrosal sinus, and the vertebral artery. The combined use of 3D CISS and 3D TOF sequences demonstrated neurovascular contacts at the nerve root entry or exit zones in 19% of all nerves visualized. The combined use of 3D CISS MR imaging and 3D TOF MR angiography (with or without contrast) successfully displays the detailed anatomy of the lower CNs and adjacent structures in vivo. These imaging sequences have the potential to aid the preoperative diagnosis of and the presurgical planning for pathology in this anatomical area.
    Journal of Neurosurgery 02/2009; 110(5):1026-41. · 2.96 Impact Factor
  • Article: Cranial MRI of small rodents using a clinical MR scanner.
    [show abstract] [hide abstract]
    ABSTRACT: Increasing numbers of small animal models are in use in the field of neuroscience research. Magnetic resonance imaging (MRI) provides an excellent method for non-invasive imaging of the brain. Using three-dimensional (3D) MR sequences allows lesion volumetry, e.g. for the quantification of tumor size. Specialized small-bore animal MRI scanners are available for high-resolution MRI of small rodents' brain, but major drawbacks of this dedicated equipment are its high costs and thus its limited availability. Therefore, more and more research groups use clinical MR scanners for imaging small animal models. But to achieve a reasonable spatial resolution at an acceptable signal-to-noise ratio with these scanners, some requirements concerning sequence parameters have to be matched. Thus, the aim of this paper was to present in detail a method how to perform MRI of small rodents brain using a standard clinical 1.5 T scanner and clinically available radio frequency coils to keep material costs low and to circumvent the development of custom-made coils.
    Methods 10/2007; 43(1):2-11. · 4.01 Impact Factor