Andreas Koops

Universität Hamburg, Hamburg, Hamburg, Germany

Are you Andreas Koops?

Claim your profile

Publications (10)48.76 Total impact

  • Article: Follow-up of radiologically totally implanted central venous access ports of the upper arm: long-term complications in 127,750 catheter-days.
    [show abstract] [hide abstract]
    ABSTRACT: The purpose of this article is to retrospectively evaluate radiologically totally implanted central venous access ports (VAPs) of the upper arm in terms of safety, technical feasibility, and device-related complications. Five hundred seven consecutive patients (mean [± SD] age, 59.2 ± 11.4 years) who received a totally implanted central VAP between January 2005 and July 2010 were included. The insertion procedure was performed in an interventional radiology suite using the Seldinger technique. Neither antibiotic prophylaxis nor long-term anticoagulation was administered. In 507 patients, a total of 523 devices were implanted. Of these 523 procedures, 512 complete datasets were available during follow-up. The primary technical success rate was 99.04%. All procedures were completed without major complications. During follow-up and with a total number of 127,750 days of totally implanted central VAP implantation (248 ± 279 days/patient; range, 1-1687 days/patient), 50 devices had to be revised because of complications (9.8%). Complications occurred at a mean of 114 ± 183 days (range, 1-1113 days) after placement. Early complications were noted in 21 of 512 cases (4.1%), and late complications were noted in 29 of 512 cases (5.7%). Complications were as follows: local infections, 4.9% (25/512); systemic infections, 0.4% (2/512); venous thrombosis, 1.6% (8/512); paralysis of the median nerve, 0.6% (3/512); skin dehiscence at the port site, 0.2% (1/512); and mechanical problems including catheter line displacement, port hub rotation, and catheter fracture, 2.1% (11/512). Radiologic placement of a totally implanted central VAP is a safe procedure with a low rate of both early and late device-related complications. The method is effective for delivery of chemotherapy, parenteral nutrition, and frequent IV medication.
    American Journal of Roentgenology 08/2012; 199(2):447-52. · 2.78 Impact Factor
  • Article: Diagnostic accuracy of state-of-the-art MDCT scanners without gantry tilt in patients with oral and oropharyngeal cancer.
    [show abstract] [hide abstract]
    ABSTRACT: PURPOSE: Current CT-protocols for staging oral and oropharyngeal cancer include primary transversal slices and secondary tilted slices to avoid artifact-producing regions of dental metalwork. Some of the latest MDCT scanners do not allow gantry tilt. Hence, we assessed the relevance of secondary tilted slices in tumor staging. MATERIALS AND METHODS: Scans of a tiltable 64-row MDCT-scanner of 82 patients with oral or oropharyngeal cancer were retrospectively and independently evaluated twice by three readers: once using the primary transversal scans only, and once taking the transversal and secondary tilted scans into account. Tumor diameters and TN-stage were determined with both methods. Artifacts on transversal scans were analyzed using a 3-point-ranking-scale. RESULTS: Image quality was impaired by severe artifacts in 24% of transversal slices of the oral cavity and in 12% of the oropharynx. The three readers detected an average of 57.7±2.1 of 82 tumors (70%) on transversal CT slices. An average of 6.3±0.6 more tumors (8%) were detected when transversal studies were evaluated in conjunction with secondary tilted slices, leading to a significantly (p=0.0156-0.0313) increased average detection rate of 64.0±2.0 tumors (78%). Moreover, secondary tilted slices led to a correction of underestimated tumor stages in up to six patients (7.3%). CONCLUSION: Tilted slices that avoid artifact-producing regions of dental metalwork significantly improve the reader's sensitivity and are of incremental value for staging of oral and oropharyngeal cancers.
    European journal of radiology 09/2011; · 2.65 Impact Factor
  • Article: Comparison of whole body MR angiography at 1.5 and 3 Tesla in patients with hereditary hyperlipidemia.
    [show abstract] [hide abstract]
    ABSTRACT: Patients suffering from hereditary hyperlipidemia have a high risk for premature cardiovascular disease and death as a consequence of accelerated atherosclerosis. To prospectively and intra-individually compare image quality and detectability of stenoses in contrast enhanced whole-body MRA (WBMRA) at 1.5 and 3 Tesla (T) in patients with hereditary hyperlipidemia. Twenty-seven patients with hereditary hyperlipidemia received a 1.5 and 3 T gadopentetate dimeglumine contrast-enhanced WBMRA. Twenty-three defined arterial segments were analyzed regarding depiction of target vessels and image quality according to a 5-point-scale ('not evaluable' to 'excellent'). Wilcoxon matched pair test was performed for comparison. Forty-three defined arterial segments were analyzed for the degree of stenosis (0%, 1-49%, 50-99% and 100%) as well as vessel alterations such as aneurysms. Chi-square test was performed for comparison. 1.5 T and 3 T scans yielded WBMRA with diagnostic quality in all patients. In seven of 23 arterial segments (30.4%) image quality was rated significantly higher at 3 T, whereas there was no significant difference in the remaining 16 segments between WBMRA at 1.5 T and 3 T. All relevant stenoses (n = 5), occlusions (n = 6), and aneurysms (n = 3) were evaluated similarly at both field strengths. WBMRA can be performed at 1.5 T and 3 T with diagnostic image quality. Image quality was significantly higher at 3 T than at 1.5 T in only 30.4% of the arterial segments. In order to effectively take advantage of the higher field strength, further optimization of sequence parameters and injection protocols for WBMRA at 3 T is necessary.
    Acta Radiologica 06/2011; 52(5):547-53. · 1.37 Impact Factor
  • Source
    Article: Interactive real-time mapping and catheter ablation of the cavotricuspid isthmus guided by magnetic resonance imaging in a porcine model.
    [show abstract] [hide abstract]
    ABSTRACT: We investigated the feasibility of real-time magnetic resonance imaging (RTMRI) guided ablation of the cavotricuspid isthmus (CTI) by using a MRI-compatible ablation catheter. Cavotricuspid isthmus ablation was performed in an interventional RTMRI suite by using a novel 7 French, steerable, non-ferromagnetic ablation catheter in a porcine in vivo model (n = 20). The catheter was introduced and navigated by RTMRI visualization only. Catheter position and movement during manipulation were continuously visualized during the entire intervention. Two porcine prematurely died due to VT/VF. Anatomical completion of the CTI ablation line could be achieved after a mean of 6.3+/-3 RF pulses (RF energy: 1807+/-1016.4 Ws/RF pulse, temperature: 55.9+/-5.9 degrees C) in n = 18 animals. In 15 of 18 procedures (83.3%) a complete CTI block was proven by conventional mapping in the electrophysiological (EP) lab. Completely non-fluoroscopic ablation guided by RTMRI using a steerable and non-ferromagnetic catheter is a promising novel technology in interventional electrophysiology.
    European Heart Journal 11/2009; 31(4):450-6. · 10.48 Impact Factor
  • Article: Catheter ablation of paroxysmal atrial fibrillation improves cardiac function: a prospective study on the impact of atrial fibrillation ablation on left ventricular function assessed by magnetic resonance imaging.
    [show abstract] [hide abstract]
    ABSTRACT: Beneficial effects of atrial fibrillation (AF) ablation have been demonstrated in patients with congestive heart failure (CHF) and significantly impaired left ventricular ejection fraction (LVEF). However, the impact of pulmonary vein isolation (PVI) on cardiac function in patients with paroxysmal AF and impaired LVEF remains under discussion. This study aimed to evaluate the impact of PVI for paroxysmal AF on cardiac function in patients with impaired LVEF using cardiac magnetic resonance imaging (CMRI). A total number of 70 patients with paroxysmal AF and episodes < or = 24 h were scanned on a 1.5-T-CMRI before and 6 months after PVI during sinus rhythm. End-diastolic volume, end-systolic volume, and LVEF were determined by epicardial and endocardial measurements. Patients were categorized into two groups regarding cardiac function as assessed by CMRI: group 1 patients (n = 18) with an LVEF < 50% and patients with an LVEF > 50% (group 2, n = 52). Group 1 patients demonstrated a significant lower success rate than patients of group 2 after a follow-up of 152 +/- 40 days (50 vs. 73%, P < 0.05). Cardiac magnetic resonance imaging in group 1 patients demonstrated a significant improvement in cardiac function after AF ablation (41 +/- 6 vs. 51 +/- 12%, P = 0.004), whereas group 2 patients did not show significant differences (60 +/- 6 vs. 59 +/- 9%, P = 0.22) after a 6 months follow-up. Pulmonary vein isolation improves cardiac function in patients with paroxysmal AF and impaired LVEF. These data suggest that an impaired LV function can be partially attributed to AF with short-lasting paroxysms.
    Europace 06/2008; 10(5):593-9. · 1.98 Impact Factor
  • Article: Evaluation of the influence of acquisition and reconstruction parameters for 16-row multidetector CT on coronary calcium scoring using a stationary and dynamic cardiac phantom.
    [show abstract] [hide abstract]
    ABSTRACT: A calcium-scoring phantom with hydroxyapatite-filled cylindrical holes (0.5 to 4 mm) was used. High-resolution scans were performed for an accuracy baseline. The phantom was mounted to a moving heart phantom. Non-moving data with the implementation of an ECG-signal were acquired for different pitches (0.2/0.3), heart rates (60/80/95 bpm) and collimations (16 x 0.75/16 x 1.5 mm). Images were reconstructed with a cone-beam multi-cycle algorithm at a standard thickness/increment of 3 mm/1.5 mm and the thinnest possible thickness (0.8/0.4 and 2/1). Subsequently, ECG-gated moving calcium-scoring phantom data were acquired. The calcium volume and Agatston score were measured. The temporal resolution and reconstruction cycles were calculated. High-resolution scans determine the calcium volume with a high accuracy (mean overestimation, 0.8%). In the non-moving measurements, the volume underestimation ranged from about 6% (16 x 0.75 mm; 0.8/0.4 mm) to nearly 25% (16 x 1.5 mm; 3/1.5 mm). Moving scans showed increased measurement errors depending on the reconstructed RR interval, collimation, pitch, heart rate and gantry rotation time. Also, a correlation with the temporal resolution could be found. The reliability of calcium-scoring results can be improved with the use of a narrower collimation, a lower pitch and the reconstruction of thinner images, resulting in higher patient doses. The choice of the correct cardiac phase within the RR interval is essential to minimize measurement errors.
    European Radiology 09/2007; 17(8):1985-94. · 3.22 Impact Factor
  • Article: Multicontrast-weighted magnetic resonance imaging of atherosclerotic plaques at 3.0 and 1.5 Tesla: ex-vivo comparison with histopathologic correlation.
    [show abstract] [hide abstract]
    ABSTRACT: The purpose was to analyze magnetic resonance (MR) plaque imaging at 3.0 Tesla and 1.5 Tesla in correlation with histopathology. MR imaging (MRI) of the abdominal aorta and femoral artery was performed on seven corpses using T1-weighted, T2-weighted, and PD-weighted sequences at 3.0 and 1.5 Tesla. Cross-sectional images at the branching of the inferior mesenteric artery and the profunda femoris were rated with respect to image quality. Corresponding cross sections of the imaged vessels were obtained at autopsy. The atherosclerotic plaques in the histological slides and MR images were classified according to the American Heart Association (AHA) and analyzed for differences. MRI at 3.0 Tesla offered superior depiction of arterial wall composition in all contrast weightings, rated best for T2-weighted images. Comparing for field strength, the highest differences were observed in T1-weighted and T2-weighted techniques (both P< or =0.001), with still significant differences in PD-weighted sequence (P< or =0.005). The majority of plaques were histologically classified as calcified plaques. In up to 21% of the cases, MRI at both field strengths detected signal loss characteristic of calcification although calcified plaque was absent in histology. MRI at 3.0 Tesla offers superior plaque imaging quality compared with 1.5 Tesla, but further work is necessary to determine whether this translates in superior diagnostic accuracy.
    European Radiology 02/2007; 17(1):279-86. · 3.22 Impact Factor
  • Article: Images in cardiovascular medicine. Development of a cardiac neocavity after mechanic double-valve replacement: evaluation by cardiac magnetic resonance imaging.
    Circulation 10/2005; 112(13):e238-9. · 14.74 Impact Factor
  • Article: Bile resistance of coated transjugular intrahepatic portosystemic shunt stents in a flow-model.
    [show abstract] [hide abstract]
    ABSTRACT: We sought to test the bile resistance of transjugular intrahepatic portosystemic shunt (TIPS) stents with 3 different coatings. Three stents with different coating materials (monolayer polyethylene terephthalate [PETP], monolayer polytetrafluoroethylene [PTFE], and double layer [PTFE]) were tested in a flow model. After testing the sealing of the system with isotonic saline solution, fresh human bile was circulated. Constant pressure was 50 cm H2O. Bile resistance of the stent membranes was analyzed. Two of the 3 stents proved completely resistant to water. Only the PETP stent was resistant to bile. The PTFE-coated stents were not bile resistant. The bile resistance of coated TIPS stents and, thus, the dependency of TIPS shunt patency is called into question. The stent with the reported superior patency rates does not show experimental bile resistance.
    Investigative Radiology 01/2005; 39(12):717-22. · 4.59 Impact Factor
  • Article: Successful resection of a symptomatic right ventricular lipoma.
    [show abstract] [hide abstract]
    ABSTRACT: We report the case of a 31-year-old woman with a 4-year history of recurrent palpitations, presenting with an increased frequency of paroxysms caused by ventricular tachycardias during pregnancy. A cardiac tumor of unknown origin infiltrating the right ventricle was diagnosed. Three weeks after prophylactic abrasion the tumor was totally excised with the use of cardiopulmonary bypass including restoration of the right ventricular wall and the tricuspid valve. Histology confirmed diagnosis of a benign cardiac lipoma. The postoperative course was uneventful and the patient was discharged 7 days after surgery. There was no episode of ventricular tachycardias during the 6-month follow-up.
    The Annals of Thoracic Surgery 11/2003; 76(4):1305-7. · 3.74 Impact Factor