An Improved Internal Mammary Irradiation Technique in Treatment of Locally Advanced Breast Cancers

Department of Radiation Oncology, Siteman Cancer Center, Washington University Medical Center, St. Louis, Missouri 63110, USA.
Journal of Applied Clinical Medical Physics (Impact Factor: 1.17). 02/2005; 6(1):84-93. DOI: 10.1120/jacmp.2023.25324
Source: PubMed


The purpose of the present study was to compare a new internal mammary irradiation technique with traditional techniques for locally advanced breast cancers in terms of sparing ipsilateral lung and heart and reducing the "cold" and "hot spots"in breast tissue. The new technique uses wide tangential fields for the first eight fractions of treatment. A medial internal mammary field (IMF) of electrons matched with narrowed tangential fields is used for the remaining fractions. Intensity-modulated radiation therapy (IMRT) by means of segmented multileaf collimation (SMLC) is used in the narrowed tangential fields to improve the match between the electron and the photon fields. Treatment planning was performed to compare this technique to a wide-tangential-only technique and to a traditional oblique IMF technique for three patients with differing habitus. Film dosimetry was performed in a solid water phantom to confirm the planning results. For all three patients, the mean doses of the ipsilateral lung and the heart were significantly reduced with the new technique. The lung and the heart volumes were remarkably reduced at lowdose levels (< or =12 Gy) compared to the traditional IMF technique, and significantly reduced at all dose levels compared to the wide tangential technique. The new technique also reduced the "cold" and "hot spots" along the match plane between the IMF and the tangential fields compared to the traditional IMF technique. In conclusion, the new IMF technique shows dosimetric improvement compared to the traditional IMF technique in terms of the critical organ sparing and target dose uniformity.


Available from: jian-yue Jin, Jan 08, 2014
  • Source
    • "Current techniques of using tangential photon adjunct fields abutting supraclavicular and posterior axillary fields are difficult enough without the addition of treating a separate medial breast internal mammary field with a mixture of photon and electrons. Though there has been extensive work to optimize these techniques (Jin et al 2005), there are shortcomings due to match-line problems and delivery of unacceptable doses to volumes of heart, lung and contra lateral breast. Ma et al (2003) compared conventional radiotherapy, IMRT and MERT for breast cancer treatment. "
    [Show abstract] [Hide abstract]
    ABSTRACT: Treating shallow tumors with a homogeneous dose while simultaneously minimizing the dose to distal critical organs remains a challenge in radiotherapy. One promising approach is modulated electron radiotherapy (MERT). Due to the scattering properties of electron beams, the commercially provided secondary and tertiary photon collimation systems are not conducive for electron beam delivery when standard source-to-surface distances are used. Also, commercial treatment planning systems may not accurately model electron-beam dose distributions when collimated without the standard applicators. However, by using the photon multileaf collimators (MLCs) to create segments to modulate electron beams, the quality of superficial tumor dose distributions may improve substantially. The purpose of this study is to develop and evaluate calculations for the narrow segments needed to modulate megavoltage electron beams using photon beam multileaf collimators. Modulated electron radiotherapy (MERT) will be performed with a conventional linear accelerator equipped with a 120 leaf MLC for 6-20 MeV electron beam energies. To provide a sharp penumbra, segments were delivered with short SSDs (70-85 cm). Segment widths (SW) ranging from 1 to 10 cm were configured for delivery and planning, using BEAMnrc Monte Carlo (MC) code, and the DOSXYZnrc MC dose calculations. Calculations were performed with voxel size of 0.2 x 0.2 x 0.1 cm3. Dosimetry validation was performed using radiographic film and micro- or parallel-plate chambers. Calculated and measured data were compared using technical computing software. Beam sharpness (penumbra) degraded with decreasing incident beam energy and field size (FS), and increasing SSD. A 70 cm SSD was found to be optimal. The PDD decreased significantly with decreasing FS. The comparisons demonstrated excellent agreement for calculations and measurements within 3%, 1 mm. This study shows that accurate calculations for MERT as delivered with existing photon MLC are feasible and allows the opportunity to take advantage of the dynamic leaf motion capabilities and control systems, to provide conformal dose distributions.
    Physics in Medicine and Biology 04/2008; 53(5):1183-208. DOI:10.1088/0031-9155/53/5/003 · 2.76 Impact Factor

  • [Show abstract] [Hide abstract]
    ABSTRACT: Sans rsum
    Oncologie 03/2006; 8(3):282-284. DOI:10.1007/s10269-006-0362-x · 0.06 Impact Factor
Show more