Reversal of ventricular dilatation in aortic regurgitation after valve replacement and cardiac support implant surgery using the CorCap cardiac support device.

Department of Cardiothoracic Surgery, Karolinska Hospital, Stockholm, Sweden.
The Annals of thoracic surgery (Impact Factor: 3.45). 08/2005; 80(1):315-6. DOI: 10.1016/j.athoracsur.2003.12.098
Source: PubMed

ABSTRACT The effects of combined aortic valve replacement, coronary bypass surgery, and passive containment surgery in a patient with long-standing aortic regurgitation and marked ventricular dilatation are described. After surgery there was a rapid decrease in left ventricular size and maintained ventricular function.

0 Bookmarks
 · 
76 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: After valve replacement in patients with aortic regurgitation short-term and long-term improvement of left ventricular function are related to early reduction of left ventricular dilatation. This case-control study was conducted to investigate the potential beneficial effects by concomitant application of the Acorn Cor Cap Cardiac Support Device (Acorn Cardiovascular Inc, St. Paul, MN) on reduction of ventricular dilatation in patients with aortic regurgitation and advanced ventricular dilatation undergoing aortic valve replacement. Of ten patients with longstanding aortic regurgitation and ventricular dilatation subjected to aortic valve replacement using mechanical valve prostheses, five were in addition subjected to application of the Cardiac Support Device (Acorn). Cardiac function and dimensions were measured by echocardiography preoperatively and 3 and 12 months postoperatively. After aortic valve replacement, there was a rapid and sustained decrease in end-diastolic and end-systolic diameters (before operation 72 +/- 4 and 54 +/- 8 mm, to 54 +/- 10 and 40 + 11 mm at 3 months; and 53 +/- 9 and 35 +/- 6 mm, 12 months after operation). This did not differ after Cardiac Support Device (Acorn) application (before operation 74 +/- 1 and 56 +/- 5 mm; 52 +/- 8 and 39 +/- 9 mm, 3 months after operation; and 54 +/- 6 and 39 +/- 8 mm, at 12 months). The left ventricular ejection fraction remained unchanged in both groups. Application of the Acorn Cor Cap Cardiac Support Device in patients with aortic regurgitation and severe ventricular dilatation does not influence reverse remodeling or cardiac function compared with aortic valve replacement alone.
    The Annals of thoracic surgery 09/2007; 84(2):510-3. · 3.45 Impact Factor

Full-text

Download
1 Download