Objective growth monitoring of the maxilla in full term infants.

Ariane Hohoff, Thomas Stamm, Ulrich Meyer, Dirk Wiechmann, Ulrike Ehmer

Poliklinik für Kieferorthopädie, Westfälische Wilhelms-Universität Münster, Waldeyer Str. 30, 48129 Münster, Germany.

Journal Article: Archives of Oral Biology (impact factor: 1.65). 04/2006; 51(3):222-35. DOI: 10.1016/j.archoralbio.2005.07.007

Abstract

OBJECTIVE: To develop a non-invasive method for longitudinal maxillary volume measurements and to provide first normative data. DESIGN: Thirty-four healthy infants served as a gold standard for a growing population sample. Alginate impressions were taken of the upper jaw within the first week after birth, and consecutively at different stages of development. The plaster casts were digitised by an optical scanner generating a high resolution polygon mesh of each object. The digital models were aligned to a reference coordinate system with an iterative, landmark-independent procedure. Biometric linear and volume measurements were obtained by using feature-dependent calculations independent of landmark placements. Intra-investigator reproducibility was tested by repeated alignments and measurements of 30 randomly selected casts. To assess the effect of mesh resolution, the reproducibility test was repeated with low resolution models. The method was proved to be valid on the defined gold standard consisting of 96 consecutive edentulous casts. RESULTS: Feature-dependent, linear distances are less error prone (0.56-2.66%) compared to subjectively determined measurements (0.88-3.65%). The same applies to feature-dependent volume calculations (4.34%) compared to subjectively determined volumes (4.95%). Mesh resolution shows an effect (p<or=0.001) only on two linear measurements: palatal depth and palatal length. Growth of the individuals in the population sample was evidently confirmed by the maxillary volume measurements (asymptotic pattern) and by comparisons of head circumference (proportional pattern). CONCLUSION: The described method is non-invasive, precise and without any risk for the infant. Maxillary volume calculation could serve as an important biometric measurement for bone growth evaluation.

Source: PubMed

Comments on this publication

ResearchGate members can add comments. Sign up now and post your comment!

Similar publications

Science & Research Jobs

Keywords

96 consecutive edentulous casts
 
Biometric linear
 
bone growth evaluation
 
described method
 
different stages
 
feature-dependent calculations independent
 
feature-dependent volume calculations
 
first normative data
 
growing population sample
 
healthy infants
 
longitudinal maxillary volume measurements
 
low resolution models
 
Maxillary volume calculation
 
maxillary volume measurements
 
mesh resolution
 
non-invasive method
 
optical scanner
 
palatal length
 
plaster casts
 
reproducibility test