Article

Silicone rubber mould cast polymethylacrylate-hydroxyapatite plate used for repairing skull defect

Department of Cranio-Maxillofacial Surgery, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania.
Journal of Cranio-Maxillofacial Surgery (Impact Factor: 2.6). 07/2006; 34(4):242-6. DOI: 10.1016/j.jcms.2006.01.005
Source: PubMed

ABSTRACT Reconstruction of the cranial vault is performed for various reasons and precise repair of the defect is important. A modified method of cranioplasty is presented using three-dimensional (3D) models and polyethylmethacrylate mixed with hydroxyapatite, cast in a silicone rubber mould.
A large custom made cranial implant was produced using data acquired from 3D computer tomography, rapid prototyping and cast in a silicone rubber mould. This plate was then applied to a 53 year-old man who had undergone a decompressive fronto-parieto-temporo-occipital craniotomy. The bone flap had been lost due to infection. The cranioplasty was performed at 1 year after the initial operation.
The cranial plate fitted precisely into the defect and needed no correction at the time of surgery. The stability of the reconstruction plate was increased by the presence of thin margins allowed by silicone rubber elasticity. No complications occurred and the final functional and aesthetic results were good.
The use of 3D imaging and rapid prototyping allow precise repair of large skull defects, with good aesthetic and functional results. At the same time, silicone rubber moulds permit the production of very thin details needed not only for cosmetic reasons but for reconstruction plate stability as well.

Download full-text

Full-text

Available from: Seong-Gon Kim, Aug 17, 2015
0 Followers
 · 
412 Views
  • Source
    • "Recent studies on cranioplasty have described the use of pre-fabricated PMMA implants for full-thickness calvarial defects [27]. These custom PMMA designs reduce operative time as well as eliminating the intra-operative "
    [Show abstract] [Hide abstract]
    ABSTRACT: Inappropriate treatment of fractures of the frontal sinus can lead to serious complications. These fractures are often associated with soft tissue injuries and loss of bony structures. This case report shows the use of methyl methacrylate frontal prosthesis to treat a sequel of frontal sinus fracture; surgical options are discusses and one-year follow-up is present to show stability and good cosmetic result.
    01/2013; 3(4):225-231.
  • Source
    • "An SLS polyamide model has been used for repairing large skull defects by constructing custom-made cranial plates. Custommade cranioplasty implants are associated with the advantages of reduced operative time, less invasive surgery, improved cosmetic results, faster recuperation, and reduced costs due to short operative times (Rotaru et al., 2006). SLS models have also allowed for the analysis of abnormalities regarding calvaria morphology, nasal bones and maxilla, improving the criteria for diagnosis and the surgical plan in a case of craniofacial dysostosis (Apert syndrome) (da Rosa et al., 2004; Sannomiya et al., 2006). "
    Advanced Applications of Rapid Prototyping Technology in Modern Engineering, 09/2011; , ISBN: 978-953-307-698-0
  • Source
    • "Comparative studies that evaluated dimensional errors between 3D CT images and different RP techniques are summarized in Table 3. Chiarini et al. (2004) used RP to plan cranioplasties. For the same purpose, Rotaru et al. (2006) simulated the reconstruction of a large cranial defect using SLS prototypes. Recently, Paeng et al. (2007) demonstrated the effectiveness of the preoperative simulation of distraction osteogenesis using biomedical prototypes in the surgical treatment of patients with hemifacial microsomia. "
    [Show abstract] [Hide abstract]
    ABSTRACT: Selective laser sintering (SLS), three-dimensional printing (3DP) and PolyJet are rapid prototyping (RP) techniques to fabricate prototypes from virtual biomedical images. To be used in maxillofacial surgery, these models must accurately reproduce the craniofacial skeleton. To analyze the capacity of SLS, 3DP and PolyJet models to reproduce mandibular anatomy and their dimensional error. Dry mandible, helical CT images, SLS, 3DP and PolyJet prototypes, and digital electronic caliper. Helical CT images were acquired from a dry mandible (criterion standard) and manipulated with the InVesalius software. Prototypes were produced using SLS, 3DP and PolyJet techniques. Thirteen linear measurements of each prototype were made and compared with the dry mandible measurements. The results showed a dimensional error of 1.79%, 3.14% and 2.14% for SLS, 3DP and PolyJet models, respectively. The models satisfactorily reproduced anatomic details and the SLS and PolyJet prototypes showed greater dimensional precision and reproduced mandibular anatomy more accurately than the 3DP model. The SLS prototype had a greater dimensional accuracy than the PolyJet and 3DP models. The PolyJet technique reproduced anatomic details of the mandible more accurately.
    Journal of cranio-maxillo-facial surgery: official publication of the European Association for Cranio-Maxillo-Facial Surgery 04/2009; 37(3):167-73. DOI:10.1016/j.jcms.2008.10.008 · 2.60 Impact Factor
Show more