An account of the discrepancy between MRI and PET cerebral blood flow measures. A high-field MRI investigation

The Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, Johns Hopkins University, Baltimore, MD, USA.
NMR in Biomedicine (Impact Factor: 3.56). 12/2006; 19(8):1043-54. DOI: 10.1002/nbm.1075
Source: PubMed

ABSTRACT There is controversy concerning the discrepancy between absolute cerebral blood flow (CBF) values measured using positron emission tomography (PET) and magnetic resonance imaging (MRI). To gain insight into this problem, the increased signal-to-noise ratio (SNR) and extended T(1) relaxation times of blood and tissue at 3.0 T were exploited to perform pulsed arterial spin labeling (PASL) MRI measurements as a function of spatial resolution and post-labeling delay. The results indicate that, when using post-labeling delays shorter than 1500 ms, MRI gray matter flow values may become as high as several times the correct CBF values owing to tissue signal contamination by remaining arterial blood water label. For delays above 1500 ms, regional PASL-based CBF values (n = 5; frontal gray matter: 48.8 +/- 3.3(SD) ml/100 g/min; occipital gray matter: 49.3 +/- 4.5 ml/100 g/min) comparable with PET-based measurements can be obtained by using spatial resolutions comparable with PET (5-7.5 mm in-plane). At very high resolution (2.5 x 2.5 x 3 mm(3)), gray matter CBF values were found to increase by 10-20%, a consequence attributed to reduction in partial volume effects with cerebrospinal fluid and white matter. The recent availability of MRI field strengths of 3.0 T and higher will facilitate the use of MRI-based CBF measurements in the clinic.

1 Follower
 · 
144 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: In addition to the BOLD scan, quantitative functional MRI studies require measurement of both cerebral blood volume (CBV) and flow (CBF) dynamics. The ability to detect CBV and CBF responses in a single additional scan would shorten the total scan time and reduce temporal variations. Several approaches for simultaneous CBV and CBF measurement during functional MRI experiments have been proposed in two-dimensional (2D) mode covering one to three slices in one repetition time (TR). Here, we extended the principles from previous work and present a three-dimensional (3D) whole-brain MRI approach that combines the vascular-space-occupancy (VASO) and flow-sensitive alternating inversion recovery (FAIR) arterial spin labeling (ASL) techniques, allowing the measurement of CBV and CBF dynamics, respectively, in a single scan. 3D acquisitions are complicated for such a scan combination as the time to null blood signal during a steady state needs to be known. We estimated this using Bloch simulations and demonstrate that the resulting 3D acquisition can detect activation patterns and relative signal changes of quality comparable to that of the original separate scans. The same was found for temporal signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). This approach provides improved acquisition efficiency when both CBV and CBF responses need to be monitored during a functional task.
    NeuroImage 08/2014; 103. DOI:10.1016/j.neuroimage.2014.08.025 · 6.13 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Caffeine, as the most commonly used stimulant drug, improves vigilance and, in some cases, cognition. However, the exact effect of caffeine on brain activity has not been fully elucidated. Because caffeine has a pronounced vascular effect which is independent of any neural effects, many hemodynamics-based methods such as fMRI cannot be readily applied without a proper calibration. The scope of the present work is two-fold. In Study 1, we used a recently developed MRI technique to examine the time-dependent changes in whole-brain cerebral metabolic rate of oxygen (CMRO2) following the ingestion of 200mg caffeine. It was found that, despite a pronounced decrease in CBF (p<0.001), global CMRO2 did not change significantly. Instead, the oxygen extraction fraction (OEF) was significantly elevated (p=0.002) to fully compensate for the reduced blood supply. Using the whole-brain finding as a reference, we aim to investigate whether there are any regional differences in the brain's response to caffeine. Therefore, in Study 2, we examined regional heterogeneities in CBF changes following the same amount of caffeine ingestion. We found that posterior brain regions such as posterior cingulate cortex and superior temporal regions manifested a slower CBF reduction, whereas anterior brain regions including dorsolateral prefrontal cortex and medial frontal cortex showed a faster rate of decline. These findings have a few possible explanations. One is that caffeine may result in a region-dependent increase or decrease in brain activity, resulting in an unaltered average brain metabolic rate. The other is that caffeine's effect on vasculature may be region-specific. Plausibility of these explanations is discussed in the context of spatial distribution of the adenosine receptors. Copyright © 2014. Published by Elsevier Inc.
    NeuroImage 01/2015; 110. DOI:10.1016/j.neuroimage.2015.01.046 · 6.13 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: BACKGROUND AND PURPOSEQuantitative signal targeting with alternating radiofrequency labeling of arterial regions (QUASAR) is a recent spin labeling technique that could improve the reliability of brain perfusion measurements. Although it is considered reliable for measuring gray matter as a whole, it has never been evaluated regionally. Here we assessed this regional reliability. METHODS Using a 3-Tesla Philips Achieva whole-body system, we scanned four times 10 healthy volunteers, in two sessions 2 weeks apart, to obtain QUASAR images. We computed perfusion images and ran a voxel-based analysis within all brain structures. We also calculated mean regional cerebral blood flow (rCBF) within regions of interest configured for each arterial territory distribution. RESULTSThe mean CBF over whole gray matter was 37.74 with intraclass correlation coefficient (ICC) of .70. In white matter, it was 13.94 with an ICC of .30. Voxel-wise ICC and coefficient-of-variation maps showed relatively lower reliability in watershed areas and white matter especially in deeper white matter. The absolute mean rCBF values were consistent with the ones reported from PET, as was the relatively low variability in different feeding arteries. CONCLUSION Thus, QUASAR reliability for regional perfusion is high within gray matter, but uncertain within white matter.
    Journal of neuroimaging: official journal of the American Society of Neuroimaging 02/2014; 24(6). DOI:10.1111/jon.12076 · 1.82 Impact Factor