Left and right ventricular diastolic dysfunction as predictors of difficult separation from cariodpulmonary bypass

Department of Anesthesia, Montreal Heart Institute, 5000 Belanger Street East, Montréal, Québec H1T 1C8, Canada.
Canadian Journal of Anaesthesia (Impact Factor: 2.53). 11/2006; 53(10):1020-9. DOI: 10.1007/BF03022532
Source: PubMed


As the evaluation of diastolic function can be complex in the setting of a busy cardiac operating room, its assessment may benefit from an algorithmic approach using transesophageal echocardiography. We developed a diagnostic algorithm which was then applied in a series of cardiac surgery patients to determine whether moderate to severe left ventricular diastolic dysfunction (LVDD) and right ventricular diastolic dysfunction (RVDD) can predict difficult separation from cardiopulmonary bypass (DSB).
An algorithm using pulsed-wave Doppler interrogation of the mitral and tricuspid valve, the pulmonary and hepatic venous flow, and tissue Doppler interrogation of the mitral and tricuspid annulus was developed. The study was divided in two phases involving two groups of patients undergoing cardiac surgery. In phase I, echocardiographic evaluations of patients (n = 74) were used to test the reproducibility of the algorithm and to evaluate inter-observer variability using Cohen's kappa values which were calculated in three specific periods. In phase II, the algorithm was applied to a second group of patients (validation group, n = 179) to explore its prognostic significance. The primary end-point in phase II was DSB.
In phase I, the kappa coefficients for LVDD and RVDD algorithms were 0.77 and 0.82, respectively. In phase II, moderate or severe degrees of LVDD were observed in 29 patients (16%) and moderate to severe RVDD was observed in 18 patients (10%) before cardiac surgery. Both moderate and severe LVDD (P = 0.017) and RVDD (P = 0.049) before surgery were observed more frequently in patients with DSB.
Moderate and severe LVDD and RVDD can be identified with very good reproducibility, and both degrees of diastolic dysfunction are associated with DSB.

Download full-text


Available from: Michel Carrier, Jan 02, 2015
22 Reads
  • Source
    • "In large cohorts of patients undergoing cardiac surgery, post-CPB LV dysfunction has been linked to age, female gender, history of heart failure, recent myocardial infarct, low LV ejection fraction, prolonged aortic cross-clamping and complexity of surgery [7-11]. More recently, echocardiographic markers of preoperative LV diastolic dysfunction have been associated with difficulties in weaning patients from CPB [12,13]. "
    [Show abstract] [Hide abstract]
    ABSTRACT: Left ventricular (LV) dysfunction frequently occurs after cardiac surgery, requiring inotropic treatment and/or mechanical circulatory support. In this study, we aimed to identify clinical, surgical and echocardiographic factors that are associated with LV dysfunction during weaning from cardiopulmonary bypass (CPB) in high-risk patients undergoing valve replacement for aortic stenosis. Perioperative data were prospectively collected in 108 surgical candidates with an expected operative mortality >or=9%. All anesthetic and surgical techniques were standardized. Reduced LV systolic function was defined by an ejection fraction <40%. Diastolic function of the LV was assessed using standard Doppler-derived parameters, tissue Doppler Imaging (TDI) and transmitral flow propagation velocity (Vp). Doppler-derived pulmonary flow indices and TDI could not be obtained in 14 patients. In the remaining 94 patients, poor systolic LV was documented in 14% (n = 12) and diastolic dysfunction in 84% of patients (n = 89), all of whom had Vp <50 cm/s. During weaning from CPB, 38 patients (40%) required inotropic and/or mechanical circulatory support. By multivariate regression analysis, we identified three independent predictors of LV systolic dysfunction: age (Odds ratio [OR] = 1.11; 95% confidence interval (CI), 1.01 to 1.22), aortic clamping time (OR = 1.04; 95% CI, 1.00 to 1.08) and Vp (OR = 0.65; 95% CI, 0.52 to 0.81). Among echocardiographic measurements, Vp was found to be superior in terms of prognostic value and reliability. The best cut-off value for Vp to predict LV dysfunction was 40 cm/s (sensitivity of 72% and specificity 94%). Patients who experienced LV dysfunction presented higher in-hospital mortality (18.4% vs. 3.6% in patients without LV dysfunction, P = 0.044) and an increased incidence of serious cardiac events (81.6 vs. 28.6%, P < 0.001). This study provides the first evidence that, besides advanced age and prolonged myocardial ischemic time, LV diastolic dysfunction characterized by Vp <or= 40 cm/sec identifies patients who will require cardiovascular support following valve replacement for aortic stenosis.
    Critical care (London, England) 06/2010; 14(3):R101. DOI:10.1186/cc9040 · 4.48 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: This chapter presents methods and protocols suitable for the identification and characterization of inhibitors of the prokaryotic and/or eukaryotic translational apparatus as a whole or targeting specific, underexploited targets of the bacterial protein synthetic machinery such as translation initiation and aminoacylation. Some of the methods described have been used successfully for the high-throughput screening of libraries of natural or synthetic compounds and make use of model "universal" mRNAs that can be translated with similar efficiency by cellfree extracts of bacterial, yeast, and HeLa cells. Other methods presented here are suitable for secondary screening tests aimed at identifying a specific target of an antibiotic within the translational pathway of prokaryotic cells.
    Methods in Enzymology 02/2007; 431:229-67. DOI:10.1016/S0076-6879(07)31012-4 · 2.09 Impact Factor
Show more